Ventricular defibrillating threshold: strength-duration and percent-success curves L. A. GeddesW. A. TackerJ. D. Bourland Tutorial Paper Pages: 301 - 305
Time-frequency analysis of the first heart sound. Part 1: Simulation and analysis D. ChenL. -G. DurandH. C. Lee OriginalPaper Pages: 306 - 310
Time-frequency analysis of the first heart sound. Part 2: An appropriate time-frequency representation technique D. ChenL. -G. DurandH. C. Lee OriginalPaper Pages: 311 - 317
New technique for time series analysis combining the maximum entropy method and non-linear least squares method: its value in heart rate variability analysis Y. SawadaN. OhtomoO. Iimura OriginalPaper Pages: 318 - 322
Non-invasive determination of instantaneous heart rate in developing avian embryos by means of acoustocardiogram R. AkiyamaH. OnoH. Tazawa OriginalPaper Pages: 323 - 327
Fluctuations in the cerebral oxygenation state during the resting period in functional mapping studies of the human brain Y. HoshiM. Tamura OriginalPaper Pages: 328 - 330
Measurement of venous oxyhaemoglobin saturation in the adult human forearm by near infrared spectroscopy with venous occlusion C. W. YoxallA. M. Weindling OriginalPaper Pages: 331 - 336
Removal of catheter distortion in multiple indicator dilution studies: a deconvolution-based method and case studies on glucose blood-tissue exchange G. SparacinoP. ViciniC. Cobelli OriginalPaper Pages: 337 - 342
Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation M. V. KamathG. TougasA. R. M. Upton OriginalPaper Pages: 343 - 347
Spike detection in biomedical signals using midprediction filter S. DandapatG. C. Ray OriginalPaper Pages: 354 - 360
Acoustical recognition of laryngeal pathology using the fundamental frequency and the first three formants of vowels E PerrinC. Berger-VachonL. Collet OriginalPaper Pages: 361 - 368
In vitro 3D reconstruction of long bones using B-scan image processing B. MigeonP. Marché OriginalPaper Pages: 369 - 372
Computerised multiparametric analysis from images of blood flow through frog mesenteric arterial bifurcation J. UmraniB. PrakashMegha Singh OriginalPaper Pages: 373 - 380
Effect of ankle-foot orthosis on active ankle moment in patients with hemiparesis S. MiyazakiS. YamamotoT. Kubota OriginalPaper Pages: 381 - 385
Technology assessment using the association between outcome measures and patterns of illness severity R. T. AlmeidaH. HjortswangJ. Persson OriginalPaper Pages: 386 - 390
Design of a summary screen for an ICU patient data management system R. H. IrelandH. V. JamesA. J. Wilson OriginalPaper Pages: 397 - 401
Biopotential amplifier for simultaneous operation with biomagnetic instruments J. VirtanenL. ParkkonenR. Näätänen OriginalPaper Pages: 402 - 408
Management of dental trauma: development of a 2D data acquisition system to evaluate passivity of dental splints J. PrévostM. NivoitY. Granjon Communication Pages: 409 - 414
Information in full and reduced data sets of electrical impedance spectra from various skin conditions, compared using a holographic neural network S. OllmarI. NicanderL. Emtestam Communication Pages: 415 - 419
Optimisation algorithms for ECG data compression D. HauglandJ. G. HeberJ. H. Husøy Communication Pages: 420 - 424
Optical assessment of recovery of tissue blood supply after removal of externally applied pressure A. MurrayD. Marjanovic Communication Pages: 425 - 427
Hopfield network applied to blood vessel detection in angiograms M. KarapatakiP. De Wilde Technical note Pages: 428 - 430
Ballistocardiogram of avian eggs determined by an electromagnetic induction coil H. OnoR. AkiyamaH. Tazawa Technical Note Pages: 431 - 435
Electromagnetic compatibility aspects of active robotic systems for surgery: the robotic prostatectomy experience F. Arámbula CosíoR. D. HibberdB. L. Davies Technical Note Pages: 436 - 440
Precision LED-based stimulator for focal electroretinography A. FaddaB. Falsini Technical Note Pages: 441 - 444
Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis Scharfetter H.Wirnsberger G. H.Hutten H. Erratum Pages: 444 - 444