Introduction

Oxidation ponds, also known as waste stabilization ponds, provide greater advantages over mechanically based units.

First, ponds can be described as self-sufficient treatment units, because the efficacy of treatment is contingent upon the maintenance of the overall microbial communities of bacteria, viruses, fungi, and protozoa (Hosetti and Frost 1995), and the proper balance of organics, light, dissolved oxygen, nutrients, algal presence (Amengual-Morro et al. 2012), and temperature. Because ponds are self-sufficient, there is a reduction of operator responsibilities to manage treatment, a reduction in labor costs, and an increase in the potential fiscal returns from the tangible products generated by the treatment unit (Hosetti and Frost 1998).

Second, ponds can be used for the purpose of ‘polishing,’ or providing additional treatment to what has been found within conventional treatment methods (Veeresh et al. 2010). Various authors have conducted studies using oxidation ponds and other treatment methods such as anaerobic digestion (Gumisiriza et al. 2009), upflow anaerobic sludge blanket (Mungraya and Kumar 2008), membranes (Craggs et al. 2004), and reverse osmosis (Lado and Ben-Hur 2010). Third, ponds simplify the treatment process by reducing the need for multiple treatment units. Finally, oxidation ponds are a treatment process that can be used in regions where treating wastewater using conventional treatment methods is very expensive. Indeed, oxidation ponds are commonly used in many regions around the world, specifically in places with year-round mild to warm climates. In many developing countries, effluent from waste stabilization ponds has been reused in aquaculture and irrigation applications. Melbourne, Australia, implements irrigation by using sewage as early as the late-1890s. Latin American countries began projects in the 1960s, while the United Nations Development Programme (UNDP) Resource Recovery Project and the Pan American Health Organization (PAHO) have collaborated in research considering ponds for growing fish (Shuval et al. 1986).

Many European Mediterranean countries also use oxidation ponds to treat municipal wastewaters. Forty-four ponds have served European populations between 500 and 40,000. Specifically in France, 77 % of the ponds have been employed to serve populations under 1000, although the largest population served was a combined 14,000 from the cities of Meze and Louipan, using a facultative pond and a maturation pond system. Ponds are also being used in countries such as Greece, Egypt, Algeria, Morocco, and Tunisia (Mara and Pearson 1998). The additional advantages and disadvantages are summarized in Table 1.

Table 1 Advantages and disadvantages of waste stabilization ponds (Mara et al. 1992)

For these reasons, the oxidation pond provides an attractive method of sustainable wastewater treatment with the following caveats: operators should monitor the chemical and biological constituents within the system to ensure proper design parameters are met to correspond with regulatory treatment efficiency standards (Hosetti and Frost 1998), especially if the effluent is to be reused.

While the authors’ research supports the use of oxidation ponds, it makes no claim concerning the closely related lagoon. Waste stabilization and oxidation ponds are synonymous, but oxidation ponds are different from lagoons. Lagoons are single or multi-celled designed natural wastewater treatment reservoirs that house diluted manure for the purpose of removing organics and other constituents by means of microorganisms or other biological processes. Similar to waste stabilization ponds, lagoons can operate under various conditions of dissolved oxygen depending on the type of microorganisms that are present. However, lagoons are more commonly affiliated with agricultural wastewater (Hamilton et al. 2006) and should not be confused with oxidation ponds.

The purpose of this text is to review the significance of oxidation ponds within wastewater treatment by discussing the types, design considerations, and treatments that have been completed by this particular method.

Types of oxidation ponds

There are four major types of oxidation ponds: aerobic (high-rate), anaerobic, facultative, and maturation ponds.

Aerobic (high-rate) ponds

Aerobic ponds, also known as high-rate algal ponds, can maintain dissolved oxygen throughout the 30–45 cm-deep pond because of algal photosynthetic activity (USEPA 2011). Photosynthetic activity supplies oxygen during the day, while at night the wind creates aeration due to the shallow depth of the pond (Davis and Cornwell 2008). Aerobic ponds are well known for having high biochemical oxygen demand (BOD) removal potential and are ideal for areas where the cost of land is not expensive. Other characteristics of these ponds include a detention time of 2–6 days, a BOD loading rate between 112 and 225 kg/1000 m3 day, and a BOD removal efficiency of 95 % (USEPA 2011).

Anaerobic ponds

Anaerobic ponds operate without the presence of dissolved oxygen. Under methanogenic conditions, the major products are carbon dioxide and methane (Quiroga 2011). Typically, these ponds are designed to have a depth of 2–5 m, with a detention time between 1 and 1.5 days, an optimum pH less than 6.2, temperatures greater than 15 °C (Kayombo et al. 2010), and an organic loading rate of 3000 kg ha/day (Quiroga 2011; Kayombo et al. 2010). Anaerobic ponds can remove 60 % BOD. However, this efficiency is climate dependent (USEPA 2011). The driving force behind treatment is sedimentation. Helminths settle to the bottom of the pond, and bacteria and viruses are removed by attaching to settling solids within the pond or die with the loss of available food or by the presence of predators. In practice, anaerobic ponds are usually incorporated alongside facultative ponds (Martinez et al. 2014).

Facultative ponds

A facultative pond is a treatment unit with anaerobic and aerobic conditions. A typical pond is divided into an aerobic surface region consisting of bacteria and algae, an anaerobic bottom region, consisting of anaerobic bacteria, and a region in between anaerobic and aerobic conditions where bacteria can thrive in both conditions (Kayombo et al. 2010; Joint Departments of the Army, the Navy, and the Air Force 1988). If used in series, effluent from a previously treated source enters the pond (Quiroga 2011; Kayombo et al. 2010). Facultative ponds treat BOD, typically within a range of 100–400 kg BOD/ha/day, by removing BOD by 95 %. Because facultative ponds employ algae as decomposers, the treatment time can range between 2 and 3 weeks, which is attributed to the photosynthetic processes that occur within the unit. A facultative pond on average has a depth of 1–2 m (Kayombo et al. 2010).

Maturation ponds

Similar to facultative ponds, maturation ponds use algae as a primary driving force in the treatment. Nevertheless, while facultative ponds typically treat BOD, maturation ponds remove fecal coliform, pathogens, and nutrients (Cinara 2004). In comparison with the other pond types, the characteristics of the maturation pond include a depth range between 1 and 1.15 m (Kayombo et al. 2010), which makes it shallower than all of the ponds besides the aerobic. Generally, maturation ponds maintain anaerobic conditions (Martinez et al. 2014).

Arrangement of ponds

Treatment by waste stabilization ponds occurs by using a single pond to handle treatment or by a multiple pond system. Figures 1, 2, 3, 4, and 5 depict a multiple pond system in Wellington, Texas, a small town in the Texas Panhandle. The system treats the town’s wastewater which is used for irrigation (Fig. 6). There are two arrangements for a multiple pond system—series and parallel. In the series arrangement, wastewater is treated in the initial and subsequent ponds and then polished in the final pond. On the contrary, wastewater flow is evenly divided in the parallel pond arrangement. The USEPA states that wastewater flow division normally occurs in the first two waste stabilization ponds (USEPA 2011).

Fig. 1
figure 1

A multiple pond treatment system in Wellington, TX, USA. The pond system consists of a facultative lagoon (1) and three oxidation ponds (24) (Google Map 2014)

Fig. 2
figure 2

Facultative lagoon in the treatment system in Wellington, TX, USA. Photograph taken by the author

Fig. 3
figure 3

Oxidation pond 1 in the treatment system in Wellington, TX, USA. Photograph taken by the author

Fig. 4
figure 4

Oxidation pond 2 in the treatment system in Wellington, TX, USA. Photograph taken by the author

Fig. 5
figure 5

Oxidation pond 3 in the treatment system in Wellington, TX, USA. Photograph taken by the author

Fig. 6
figure 6

Central pivot irrigation system directly applies effluent from the pond system in Wellington, TX, USA. Photograph taken by the author

Each multiple pond arrangement has its benefits and therefore an operator can change the pond arrangement depending on the situation. For example, ponds operating in parallel prevent interruption of treatment during the cooler months of the year. This is when a pond can experience low biological activity. Low biological activity can create anaerobic conditions within a pond. In addition, the application of ponds in parallel can reduce problems related to periodic low dissolved oxygen concentrations, particularly in the morning hours (USEPA 2011). Also, Mara and Pearson (1998) recommend this arrangement when the population of the city reaches 10,000. On the other hand, ponds in series are ideal during the summer months and also during periods of low biological loading (USEPA 2011). Nevertheless, the choice of applying multiple ponds can be beneficial for treatment as compared to a single pond arrangement.

Design of oxidation ponds

Oxidation ponds are designed to function as either completely stirred or plug flow reactors, but mass transport mechanisms have a greater impact than the type of reactor model chosen. There are four major mass transport mechanisms acting in oxidation ponds—diffusion, advection, gravity, and interception. The mechanism(s) observed are contingent on the type of wastewater treated (Peña and Mara 2003).

There are many methods available for the design of waste stabilization ponds. For example, facultative pond design can use the areal loading rate, Gloyna equation, plug flow model, Marais and Shaw model, and the Thirumurthi application. The design equations for each procedure together with design limitations are shown below.

Areal loading rate

The areal loading rate design procedure optimizes an organic loading rate into a waste stabilization pond by examining various factors such as the volumetric loading, organic constituents within the wastewater, the ability of algae to use sunlight to grow and supply oxygen, and BOD loading per unit area (USEPA 1983). Climate impacts the BOD loading rate, as the loading rate is directly related to the ability of a pond to avoid becoming anaerobic (Gloyna 1971). The areal loading rate procedure limits BOD5 loading rates between 11 and 22 kg/ha/day when the temperature is below 0 °C and a hydraulic detention time between 120 and 180 days (Gloyna 1971; USEPA 2011), as opposed to tropical climates which can handle higher BOD5 loading rates. Therefore, the use of areal loading rate is climate dependent and may not be as predictable as other methods.

Gloyna equation

Authors Hermann and Gloyna attempted to address the limitations of the areal rate procedure with a method of determining the volume of a waste stabilization pond that would maintain a high BOD removal (80–90 %) despite the change in temperatures (Marais 1966). The authors state that if the average coldest water temperature of the year is known along with a loading factor based on the product of the total population and waste per capita, the volume of the pond can be determined graphically. The procedure is as follows. The design engineer begins by computing the loading factor. Because the graph consists of lines representing water temperatures, the engineer would find the computed loading factor on the abscissa, move vertically toward the average coldest temperature line, and read the volume on the ordinate. After selecting the volume, the depth was found using a table of recommended depths (Gloyna 1971).

Gloyna further expanded on this to create an empirical equation that summarizes the relationship between pond volume, BOD concentration, and flow rate (Finney and Middlebrooks 1980):

$$V = 3.5 \times 10^{ - 5} QL_{a} \left( {{\ominus }^{(35 - T)} } \right)ff^{{\prime }} ,$$
(1)

where V is the pond volume, m3; Q the influent flow rate, l/day; L a the ultimate BOD or COD, mg/L; Ө the temperature coefficient; T the pond temperature, Celsius; f the algal toxicity factor (1.0 for domestic and industrial wastes); f′ the sulfide oxygen demand (1.0 for SO4 concentration less than 500 mg/L).

In addition, Gloyna attempted to adjust for sunlight by multiplying the computed volume from Eq. (1) and the quotient of solar radiation in the area and the solar radiation found in the southwest.

However, there are several limitations within the Gloyna equation. Finney and Middlebrooks argued that the use of Gloyna’s equation cannot be applied to all ponds, because it does not always correctly predict pond depths or BOD removal efficiencies. The authors also mention that the sunlight correction can have more of an impact on the volume than the other variables in the equation (Finney and Middlebrooks 1980). In addition, Marais (1966) concluded that the sizing of ponds by Gloyna’s equation results in the design of smaller ponds in series, rather than using one larger pond to meet the same treatment objective.

Plug flow model

The plug flow model, derived from first-order kinetics, considers not only the BOD5 concentration, but also the rate reaction rate (k p). The k p is chosen based on the BOD5 loading rate and the pond temperature. Table 2 provides the k o based on BOD5 loading rate at 20 °C (USEAP 1983). The plug flow model is presented in Eq. (2) at a temperature of 20 °C (USEPA 1983):

Table 2 BOD5 loading rate based on k p at 20 °C (USEPA 1983)
$$C_{\text{e}} /C_{\text{o}} = \, e^{{ - k_{\text{p}} t}} ,$$
(2)

where C e is the effluent BOD5 concentration, mg/L; C o the influent BOD5 concentration, mg/L; e the base of natural logarithm, 2.7183; k p the plug flow first-order reaction rate, day−1; t the hydraulic resident time in each pond, days.

To use the plug flow model at other temperatures, a subsequent equation is required. Equation (3) converts the temperature from 20° to the desired temperature (USEPA 1983):

$$k_{{{\text{p}}_{T} }} = k_{{{\text{p}}_{20} }} \left( {1.09} \right)^{T - 20} ,$$
(3)

where \(k_{{{\text{p}}_{T} }}\) is the reaction rate at minimum operating water temperature, day−1; \(k_{{p_{20} }}\) the reaction rate at 20 °C; T the minimum operating water temperature,  °C.

Marais and Shaw

Marais and Shaw developed a pond equation that combines both first-order kinetics and completely mixed conditions (Crites et al. 2006). This can also be used by designers for aerobic pond design (USEPA 2011; Crites et al. 2006):

$$C_{\text{n}} /C_{\text{o}} = 1/\left( {1 + \, k_{\text{c}} t_{\text{n}} } \right)^{n} ,$$
(4)

where C n is the effluent BOD5 concentration, mg/L; C o the influent BOD5 concentration, mg/L; k c the complete-mix flow first-order reaction rate, day−1; t n the hydraulic resident time in each cell, days; n the number of equal-sized pond cells in series.

The developed equation is based on the following assumptions (Marais 1966; Finney and Middlebrooks 1980):

  1. 1.

    Assume that the pond is completely mixed, with no changes in pond state.

  2. 2.

    Treat the pond effluent as equal to the influent under equilibrium conditions, with slight variations of pollutant concentration within the influent.

  3. 3.

    Pollution removal increases within a series of ponds until reaching a desired removal rate.

  4. 4.

    BOD does not settle as sludge (Finney and Middlebrooks 1980).

Thirumurthi application

Thirumurthi argued that Marais and Shaw’s assumption of completely mixed conditions is not ideal for designing a waste stabilization pond, but suggests using a chemical reaction (Eq. 5) (Finney and Middlebrooks 1980; Thirumurthi 1974):

$$C_{\text{e}} /C_{\text{i}} = 4ae^{1/2d} /\left( {1 + a} \right)^{2} e^{a/2d} {-}\left( {1 - a} \right)^{2} e^{ - a/2d} ,$$
(5)

where C e is the effluent biochemical oxygen demand (BOD), mg/L; C i is the influent BOD, mg/L; K is the first-order BOD removal coefficient, day−1; t is the mean detention time, days; a = √(1 + 4Ktd); d = Dt/L 2; d is the dimensionless dispersion number; D is the axial dispersion coefficient, ft2/h.

The thesis of this application is to focus on the first-order BOD removal coefficient (K), making corrections due to temperature, organic load, toxic contaminants, and solar radiation (Thirumurthi 1974). Equation (6) summarizes the factors that are associated with K (Finney and Middlebrooks 1980; Thirumurthi 1974):

$$K = K_{8} C_{\text{Te}} C_{\text{o}} C_{{{\text{T0}}x}} ,$$
(6)

where K is the first-order BOD removal coefficient, day−1; K 8 the BOD5 removal coefficient, day−1; C Te the correction factor for temperature; C o the correction factor for organic load; C T0x the correction factor for toxic chemicals.

Anaerobic pond design

Anaerobic pond design is contingent on the volumetric loading rate into the pond. This is based on the water temperature and hydraulic retention time. Table 3 provides treatment efficiency based on major operating parameters.

Table 3 Operating parameters for anaerobic ponds (USEPA 2011)

Overall, there are different methods that can be utilized to design a waste stabilization pond. Choosing the appropriate design technique requires careful consideration of assumptions and limitations, pond type, and the wastewater quality indicators that are desired to be analyzed and removed.

Operation and design parameters

Operation parameters

The major operation parameters for oxidation ponds include light penetration, temperature, wind, pond geometry, and oxygen concentration.

Light penetration

Light penetration affects the process of photosynthetic organisms utilizing sunlight to produce oxygen. Therefore, recognizing such factors as an organism’s ability to absorb light at given wavelengths (optimal wavelength range for photosynthesis is between 400 and 700 nm), also known as photosynthetic active radiation (PAR) (Curtis et al. 1994), the presence of suspended material, and the climate and geographic location of the pond (USEPA 2011) will assist in providing a framework for evaluation during operation. In addition, the natural scattering of light particles due to water characteristics and the presence of microorganisms can further impact the usefulness of light that enters into the pond (Curtis et al. 1994).

Temperature

Since this is a natural treatment system, it is also important to understand that the temperature cannot be regulated. Rather, temperature analysis plays a significant role in understanding the efficiency of the oxidation pond as a treatment system, the control of nitrification (Kirby et al. 2009), methane production during anaerobic digestion (Sukias and Craggs 2011), COD removal (Daviescolley et al. 1995), the handling of heavy metals (Mona et al. 2011), bacteria growth (Halpern et al. 2009; Olaniran et al. 2001), and the influence of bacteria and algal presence on pond productivity (Quiroga 2011).

One of the major ways that temperature impacts pond productivity is during the summer and winter months, when the surface water heated by the sunlight remains at the top of the pond and cooler denser water is at the bottom. The noticeable change in temperature with increasing depth creates layers or ‘strata’, a phenomenon known as stratification. Stratification is intensified in the winter months when sheets of ice can form within the pond layers, reducing light penetration and further water layer formation (USEPA 2011). Access to sunlight is limited during both seasons producing anaerobic conditions (Marais 1966). Stratification limits the metabolism of algae and aerobic bacteria in the pond.

Conversely, during the spring months, temperature differences are lessened, and surface water and water at lower depths will combine by mixing (USEPA 2011). Mixing also causes turnover of sediments from the bottom of the pond increasing the available suspended solids concentration to be removed by microorganisms (Finney and Middlebrooks 1980). Seasonal changes impact the water depth through rainfall and evaporation (Hamilton et al. 2006).

Wind

Wind is important in preventing anaerobic conditions by mixing warmer and cooler layers of water (USEPA 2011; Marais 1966). This reduces the potential for stratification, odors, and short-circuiting (USEPA 2011). However, the effectiveness of wind energy is contingent on the temperature of the pond, as the required energy to reduce 1° of pond temperature increases with increasing temperature of the pond (Marais 1966).

Wind patterns and wind speed control the overall removal of bacteria. Various studies compare wind speeds, direction, and also the implementation of baffles within the simulated waste stabilization ponds. The factors related to bacteria removal include the direction, speed of wind, and the presence of baffles, particularly L-shaped baffles, where winds blowing parallel to the inlet–outlet of the pond produce poorer results as compared to the orthogonal orientation of the pond. Nevertheless, the results may vary with increasing wind speeds (Badrot-Nico et al. 2010). Wind coupled with pond geometry can likewise have an impact on treatment performance. For example, in the aerobic layer of facultative ponds the presence of wind leads to vertical mixing and the distribution of dissolved oxygen, bacteria, algae, and BOD. This creates a quality effluent. However, without the wind, algae create a 20 cm-thick layer moving through 50 cm of the pond. This leads to a variable quality effluent (Mara and Pearson 1998).

Pond geometry

Having analyzed two different pond types with varying dimensions and depths, Pearson et al. (1995) confirmed that pond geometry alone does not indicate a strong relationship with treatment performance. Consequently, optimum treatment can be achieved at low dimension ratios, along with shallower pool depths. This can eliminate high construction costs. While the pond geometry may not have indicated an effect on a pond’s performance, Hamdan and Mara’s comparison between horizontal and vertical pond orientation for the treatment of total Kjeldahl nitrogen (TKN) showed that the vertical-flow orientation has a better treatment performance as compared to the horizontal flow (Hamdan and Mara 2011).

In addition, Abbas et al. (2006) concluded that the dimensions of the waste stabilization pond affect the removal of BOD5. Their model, initiated from the conservation of moment and mass equations solved by using Newton–Raphson non-linear iterations, find increasing BOD5 removal when the number of baffles was 2. High performance is found regardless of the dimensions at four baffles (peak performance recorded at a dimension ratio of 4, BOD5 = 95.8 %), while low performance is seen at no baffles (ranging from 16.1 to 21.6 %, from 1 to 4 dimension ratio). Therefore, pond geometry can monitor the efficiency of pollutant removal in a pond.

Design factors

Understanding design factors is important in controlling pollutants such as BOD5. There are many factors that affect the efficiency of BOD5 removal in waste stabilization ponds. These factors include raw wastewater strength, food-to-microorganism ratio, organic loading rates, pH, and hydraulic detention time (HRT).

Hydraulic retention time is important because it determines not only how long the wastewater remains within the pond, but also the treatment efficiency. In general, the HRT was found to be as low in literature as 18 h (Gumisiriza et al. 2009) and as high as 300 days (Shpiner et al. 2007). Various authors propose different HRT values because of the type of wastewater treated and the type of pond treatment applied. For example, 18 h is sufficient to treat fish-processing wastewater by combining the oxidation pond with anaerobic digestion (Gumisiriza et al. 2009), while Quiroga (2011) recommends that the retention time for the design of an anaerobic pond in Canada range between 2 and 5 days.

The significance of the pH range becomes important when taking into account the presence of microorganisms and other biological species that are needed for the purpose of enhancing treatment. The pH has been regulated for optimum growth of algal species (Bhatnagar et al. 2010), sulfate-reducing bacteria (Burns et al. 2012), macrophytes (Kirby et al. 2009), and Salvinia rotundifolia (Banerjee and Sarker 1997). For example, photosynthesis by algae increases pH through the presence of hydroxide ions that are formed by the use of carbon dioxide (USEPA 2011). Various authors set the pH range as low as 3–5 (Burns et al. 2012), while the highest pH range is 4–11 (Bhatnagar et al. 2010).

While this text studies the aforementioned as the most frequent parameters, other parameters may have an effect on an oxidation pond’s performance, such as flow rate (Kirby et al. 2009; Faleschini et al. 2012), volume (Fyfe et al. 2007), and area (Craggs et al. 2003). However, there are still other parameters that can be considered, but the previously mentioned have been surveyed as having the most effect on the overall treatment of wastewater within oxidation ponds.

Wastewater characteristics

The characteristics of wastewater are very important when determining the most efficient treatment system. Oxidation ponds treat various wastewaters consisting of nitrogen and phosphorus, heavy metals, organics, and pharmaceuticals. The following includes the mechanisms involved in treating for these specific constituents, along with results that have been outlined in the literature.

Nutrients

In the case of nitrogen, volatilization, specifically ammonia volatilization, is the most common method applied (USEPA 2011; Kayombo et al. 2010). Other methods for reducing nitrogen include deposition, adsorption, nitrification, and denitrification (USEPA 2011). On the other hand, phosphorus treatment uses various processes such as precipitation, sedimentation, and uptake by algal biomass (Kayombo et al. 2010). Nevertheless, oxidation ponds have been effective in removing nutrients.

Nutrient removal is contingent upon the type of oxidation pond (Kayombo et al. 2010). For example, Ke et al. (2012) combined submerged macrophyte oxidation ponds (SMOPs) and subsurface vertical-flow (SVFW) ponds to treat particulate phosphorus (PP) and total dissolved phosphorus (TDP). Garcia et al. (2002) combine two high-rate oxidation ponds (HROPs) for phosphorus removal. Other treatment processes include a hybrid system (oxidation pond, a two-stage surface wetland system, and one subsurface-flow wetland) for the treatment of total Kjeldahl nitrogen (TKN) and ammonium (Yeh et al. 2010), four 3.09-ha high-rate algal ponds (HRAPs) treating ammonia-N and dissolved reactive phosphorus (Craggs et al. 2012), high-rate pending (HRP) treatment system for nitrogen and phosphorus (Nurdogan and Oswald 1995), and shallow waste ponds for removing ammonia in landfill leachate (Leite et al. 2011). Tsalkatidou et al. (2013) combined eight vertical construction wetlands, three facultative ponds, and aerobic and maturation ponds to treat nutrient constituents such as nitrate-N, ammonia-N, and total phosphorus. Table 4 summarizes the values for the treatment efficiencies for each nutrient.

Table 4 Treatment efficiencies of nutrients in oxidation ponds

Heavy metals

Without proper treatment, heavy metals at high concentrations can significantly impact the environment and human health, causing damage to the colon, kidneys, skin, and nervous, reproductive, and urinary systems, yet the impact of a heavy metal is contingent on the type and concentration (Ogunfowokan et al. 2008). Nevertheless, oxidation ponds impact human health, causing damage to the colon, kidneys, skin, and nervous, reproductive, and urinary systems, yet the impact of a heavy metal is contingent on the type and concentration (Ogunfowokan et al. 2008). Nevertheless, oxidation ponds can be utilized to treat wastewater with heavy metals by reducing its concentration prior to discharge.

Several studies have been done to examine the result of oxidation ponds in treating heavy metals. Ali et al. (2011) found that the effluent from treating heavy metals enhanced the quality of soil and increased plant growth potential. Other authors have considered the effects of heavy metal removal in oxidation ponds. Table 5 summarizes the treatment efficiency of heavy metals.

Table 5 Treatment efficiencies of heavy metals in oxidation ponds

Organics

Organic removal can be accomplished using either anaerobic or aerobic conditions. In aerobic conditions, organic degradation is a two-stage process. During the first stage, bacteria degrade organic matter into carbon dioxide, water, phosphorus, and ammonia in the presence of oxygen. Next, algae in the presence of light use carbon dioxide and water from bacteria to produce oxygen, water, and new algae. The cycle is repeated—oxygen from the second stage is used by the bacteria to restart the first stage of organic degradation. Under anaerobic conditions (commonly known as anaerobic digestion), the process consists of hydrolysis, acidogeneis, acetogenesis, and methanogenesis. In anaerobic digestion, organic matter is degraded into methane, carbon dioxide, and water (Arthur 1983). During these processes, bacteria and algal biomass increase with decreasing organic material.

Various authors report removal of various forms of organics by oxidation ponds—54 % removal of fluorescent organic matter (Musikavong et al. 2007), 64.77 and 97.75 % of polycyclic biphenyls (PCBs) (Badawy et al. 2010), and 54 % of dissolved organic matter (Musikavong, and Wattanachira 2007). The BOD removal efficiency is dependent on numerous factors and can vary from approximately 81 % (Yeh et al. 2010), 50 % (Craggs et al. 2003), 50.3 % (Meneses et al. 2005), and others (Banerjee and Sarker 1997; Faleschini et al. 2012; Mtethiwa et al. 2008; Sukias et al. 2001; Tanner and Sukias 2003; Abbasi and Abbasi 2010). The BOD removal is not only dependent on the type of oxidation pond, but on other factors such as the environment (Mara and Pearson 1998).

Other applications

Oxidation pond treatment analysis has been made in other applications. Spongberg et al. (2011) analyzed oxidation pond treatment performance on pharmaceuticals such as doxycyclines, salicylic acid, triclosan, and caffeine. Gomez et al. (2007) observed 90–95 % removal of estrogenicity. Ahmad et al. (2004) measured low concentrations of pesticides such as heptachlor, dieldrin, and pp-dichlorodiphenyltrichloroethane from oxidation pond sludge samples. Khan et al. (2010) analyzed the growth of sorghum using treated wastewater from oxidation ponds.

Pathogens

From a public health perspective, the overall effects of the presence of pathogens must be taken into account. There are several problematic pathogens such as bacteria, protozoa, helminths, and viruses, which can cause various diseases such as cholera, gastroenteritis, typhoid fever, dysentery, and hepatitis (Parker 1970). The World Health Organization (WHO) provides stringent requirements for effluent based on the amount of pathogens present within the system. For example, nematode discharge is limited to 1 egg/L into the system (Mara and Pearson 1998). Human health impacts of microorganisms such as chironomid eggs (Senderovich et al. 2008) have also been discussed for their potential effects on public health and the environment. WHO discusses additional concerns for bacteriophage species, F-RNA, and somatic coliphages 103–104 plaque-forming units/mL (Gino et al. 2007), and somatic coliphage (phiX-174) and F-specific RNA phage (MS2) (Benyahya et al. 1998).

Oxidation ponds are capable of treating pathogens as well. There are several parameters that are necessary for treating bacteria—time and temperature, pH, light intensity, and dissolved concentration (Mara and Pearson 1998). Maiga et al. (2009) found E. coli inactivation to be contingent on sunlight, pH, and dissolved oxygen concentration. In addition, Reinoso and Becares (2008) observe that the prevalence of sunlight reduces Cryptosporidium parvum by 40 %. Oxidation ponds can also reduce other pathogens such as Campylobacter jejuni, Salmonella enterica, and E. coli (Sinton et al. 2007), reducing salmonella in particular by 96.4 % (Gopo et al. 1997). Oxidation ponds can also remove viruses (NoV), 47 % geogroup I (GI) and 67 % geogroup II (GII) (Da Silva et al. 2008).

Oxidation ponds can eliminate fecal coliform, fecal enterococci, F+ coliphage, somatic coliphage, and Ascaris eggs by using the four ponds (Nelson et al. 2004). A treatment system consisting of activated sludge, extended aeration, physical, chemical, and biological treatment (BIOFORE), and oxidation ponds successfully removes pathogens (Jamwal et al. 2009), while a pond and wetland system minimizes bacteria by at least one log (Tanner and Sukias 2003). Overall, oxidation ponds can remove pathogens given that the detention time is between a few days to several weeks (Gloyna 1971).

Algae

Algae are one of the more perennial driving forces with respect to proper treatment within oxidation ponds and are important because they are capable of taking up phosphates, carbon dioxide (CO2), and nitrogen compounds such as ammonia and nitrates, incorporating these constituents into algal biomass production. At the same time, algae supply the oxygen necessary for heterotrophic bacteria to degrade organic material (USEPA 1983). Literature describes that a strong algae presence is determined by nutrients, temperatures, and sunlight. Sunlight is also linked to dissolved oxygen concentration (mg/L) and can predict photosynthetic activity.

There are various algal species utilized such as Chlamydomonas and Euglena. Nevertheless, algae such as Scenedesmus acutus within high-rate oxidation ponds (HROPs)-sedimentation systems reduce TSS (Garcia et al. 2000), while algae species Chlorella vulgaris and Oscillatoria brevis are also effective in treatment (Tharavathi and Hosetti 2003). In addition, microalgae treat polycyclic aromatic hydrocarbons (PAHs), phenolics, and organic solvents (Munoz and Guieysse 2006). Advanced oxidation systems also use microalgae (Ahmad et al. 2004). Other examples of algae species can include Phacus from the phylum Euglenophyta, Chlamydomonas, and Eudorina, (Chlorophyta); Navicula and Cyclotella (Chrysophyta); and Anabaena (Cyanophyta) (Mara and Pearson 1998).

Yet, there are limitations with algae. One of the biggest known problems is finding algae following discharge from the pond (USEPA 1983). Kaya et al. (2007) found that the algae problem is related to high suspended solids (SS) concentrations. Having observed these issues, the authors find that using a laboratory-scale step feed dual treatment (SFDT) and trickling filter (TF) as an addendum to the oxidation ponds improves chlorophyll-a (Chl-a) from 89.4 to 97 %, as long as the hydraulic loading rate is 2 m3/m2 day. In this study, the TF alone removes 88 and 95 % Chl-a. Besides the SS concentrations, additional problems may include the clogging of the system when improperly discharged (Arthur 1983).

Despite these limitations, algae grown within the pond can be harvested (converted into biomass) for the purpose of creating an alternative fuel source, provided that the influent does not contain heavy metals. As a fuel source, algae have many advantages—high productivity, short growth time, low land requirements, and the formation of lipids capable of being converted into fuels (Pittman et al. 2011). Studies show that lipids have a dry weight range between 10 and 30 %, where the values can be contingent on the type of wastewater and its associated concentrations (Pittman et al. 2011; Rawat et al. 2011). Algal harvesting creates biofuels such as gas or oil-based fuels, hydrogen gas (Pittman et al. 2011), ethanol, biogas from methane for electricity (Rawat et al. 2011), and biodiesel, a fuel that is biodegradable, renewable, and low in CO2 emissions (Brennan and Owende 2010). Depending on the species, the amount of gas production will vary. For example, Chlorella vulgaris has a potential methane production between 0.6 and 0.8 L/g volatile suspended solids (VSS), while Chlorella pyrenoidosa produces 0.8 L/g VSS. Other algae species such as Scenedesmus obliquus ranged from 0.6 to 0.7 L/g VSS (Singh and Olsen 2011).

Biofuel formation from algae consists of two major processes—conversion of algae into biomass, followed by the formation of gas based on biochemical and thermochemical processes (Pittman et al. 2011; Rawat et al. 2011). Figure 7 provides a process flow diagram of the algal harvesting process. Conventional algal harvesting begins with flocculation, or the neutralization of the negatively charged algal constituents for the purpose of aggregation (Pittman et al. 2011; Rawat et al. 2011). Flocculation occurs by the use of alum (Pittman et al. 2011) or polymers (Rawat et al. 2011). Following flocculation, biomass is then separated from algal cells and recovered by the use of either centrifugation or gravity sedimentation. An additional biomass recovery procedure consists of biomass attached onto constituents such as alginates in a process known as immobilization (Pittman et al. 2011; Rawat et al. 2011).

Fig. 7
figure 7

Conventional process flow diagram of algal harvesting process for biofuel production (adapted from Pittman et al. 2011; Rawat et al. 2011)

Following algal harvesting, the biomass undergoes thermo or biochemical processes, converting biomass into biofuels, where thermochemical processes can include gasification, pyrolysis, liquefaction, and combustion, while anaerobic digestion and fermentation encompass the major biochemical processes (Pittman et al. 2011; Rawat et al. 2011). Table 6 describes some of the major thermochemical processes that have been employed for biomass conversion. Nonetheless, algal harvesting has several limitations.

Table 6 Thermochemical processes used in biomass conversion

First, the majority of the algae are unicellular and low in density, making harvesting very expensive (Rawat et al. 2011; Brennan and Owende 2010). Second, several life cycle assessments (LCAs) indicate that various setbacks need to be addressed. An LCA completed by Campbell et al. (2011) found that while biodiesel reduces greenhouse gas emissions when compared with fossil fuel and canola-based biodiesel production of 15 g/m2 day and 30 g/m2 day, biodiesel is more expensive than fossil fuel and canola-based fuels (Campbell et al. 2011). Singh and Olsen (2011) concluded that biodiesel production has high electricity costs and water requirements—for every 1 kg of biodiesel produced, 3726 kg of freshwater is required. Algal harvesting also requires a supply of nitrogen, usually from chemical fertilizers (Clarens et al. 2010), phosphorus, potassium, and sulfur (Singh and Olsen 2011). Another LCA finds that when comparing algae, corn, canola, and switchgrass as a potential biofuel, algae have the highest energy production, lowest land requirement, and eutrophication potential, but corn and switchgrass reduce greenhouse gases more efficiently (Clarens et al. 2010).

On the other hand, there are ways to resolve these difficulties and continue using algae for biofuel production. For example, if algae are grown within wastewater or saltwater, water requirements are reduced to approximately 400 kg/1 kg of biodiesel, along with nutrients due to their availability within wastewater (Singh and Olsen 2011; Clarens et al. 2010). Still, future studies need to be conducted to address many of the concerns that have been mentioned in the various life cycle analyses, specifically the costs associated with using algae biomass for the purpose of forming biofuels.

A more recent application is the uptake of phosphorus by algae within waste stabilization ponds. Phosphorus uptake by microalgae is necessary, but only in limited quantities. Nevertheless, there are some instances where the uptake of phosphorus by microalgae is greater than what is required for viability. This process is known as luxury uptake. In luxury uptake, microalgae take available phosphorus from the environment and store unused phosphorus as polyphosphate. The forms of polyphosphate stored are either acid-soluble polyphosphate (ASP) or acid-insoluble polyphosphate (AISP). Stored polyphosphates are used in situations when phosphate concentrations are low.

Luxury uptake has been observed in natural environments. In literature, the authors evaluate luxury uptake on three factors—phosphorus concentration, light intensity, and temperature. Results from the study indicate that the use of phosphorus concentration is contingent on the difference between batch and continuous reactors. Light intensity and temperature affect the rate of polyphosphate accumulation by algae. Full-scale waste stabilization ponds validate the experiments. However, luxury uptake research is still in infant stages. Questions such as determining the effects of mixing and detention time on phosphorus uptake and the optimum ideal phosphorus, bacteria, and algal concentrations still need to be answered (Brown and Shilton 2014).

Greenhouse gas emissions

Despite many advantages, waste stabilization ponds have been linked with emitting greenhouse gases. There are three recognized greenhouse gases—methane (CH4), carbon dioxide (CO2), and nitrous oxide (NOx) (Hernandez-Paniagua et al. 2014; Khatiwada and Silveira 2011). In general, wastewater treatment processes contribute to 5 % of the greenhouse gas production in the world, where anaerobic treatment methods are the most responsible (Cakir and Stenstrom 2005). According to Hernandez-Paniagua et al. (2014), stabilization ponds typically emit 85 g/m2 day of CO2 and 86 g/m2 day of CH4, with nitrous oxide levels significantly lower. In fact, methane emissions in a waste stabilization pond were reported to be twice as high compared to activated sludge systems (Hernandez-Paniagua et al. 2014).

At the aerobic layer near the surface of the pond, methane will oxidize to CO2. However, it has been observed that methane emissions are much higher in ponds as compared to carbon dioxide (Silva et al. 2012). This has been attributed to the fact that during photosynthesis algae, use atmospheric carbon dioxide, raising the pH. At higher pH levels, dissolved carbon dioxide is converted to carbonic acid and bicarbonates (Silva et al. 2012). Algae are also responsible for biologically fixing carbon dioxide and converting atmospheric carbon dioxide into a solid, thereby reducing the emission of CO2 (Shilton et al. 2008). Nevertheless, the release of CO2 into the atmosphere is still dependent upon the pH value of the system.

While waste stabilization ponds are responsible for a small portion of the world’s greenhouse gas emissions (particularly methane), there is an opportunity for the gas, commonly known as biogas, to be recovered and used as a source of energy (Konate et al. 2013). While biogas primarily consists of methane, it is also made up of carbon dioxide, oxygen, and other gases (NIWA 2008). Nevertheless, methane is the main gas targeted when considering biogas recovery. Biogas is formed either during anaerobic digestion of organic compounds or the reduction of carbon dioxide and hydrogen (El-Fadel and Massoud 2001). As a viable energy option, it has been seen as being ideal for electricity generation in a wastewater treatment plant as natural gas, provided that it has undergone several treatment processes (Craggs et al. 2014), or for heat and power (NIWA 2008). If biogas is not recovered for energy, it can be flared off or transitioned into an aerobic pond if a multiple pond system exists (NIWA 2008).

The recovery of biogas is not a novel idea. As a matter of fact, recovery of biogas in pond systems began appearing in peer-reviewed journals within animal waste operations no later than the 1970s (Safley and Westerman 1988). Recently, authors have studied biogas recovery in stabilization ponds from various types of wastewater. For example, Park and Craggs (2007) found a mean areal biogas production of 0.78 m3/m2 day from piggery wastewater and 0.03 m3/m2 day from dairy wastewater (Park and Craggs 2007). Konate et al. (2013) recorded a mean areal biogas production of 0.121 m/m2 day from domestic wastewater in an anaerobic pond. McGrath and Mason (2004) observed biogas production between 0.002 and 0.039 m3/m2 day in dairy wastewater. Heubeck and Craggs (2010) found an average annual methane production rate of 0.263 m3 CH4/kg VSSadded from a piggery pond.

For a pond to be efficient in producing a substantial amount of biogas to be recovered, several parameters must be considered. Two of the most important parameters are the ambient air and pond temperatures. It has been determined that there is a power law relationship between biogas production and ambient temperature. This is expressed in the following equation (McGrath and Mason 2004):

$$R \, = \, 1.241\left( {T_{\text{a}} } \right)^{1.127} ,$$
(7)

where R is the areal biogas production (L/m2 day) and T a the ambient air temperature ( °C).

With regard to pond temperature, typical biogas production in stabilization ponds occurs in the temperature range between 10° and 30° where a linear relationship exists between 10° and 20° (McGrath and Mason 2004). Other parameters can include pond geometry (Konate et al. 2013), pH, retention time, treatment method, and microorganism presence (El-Fadel and Massoud 2001). BOD and COD loading rate is also important as the production of methane increases with increase in wastewater strength (El-Fadel and Massoud 2001; Cakir and Stenstrom 2005).

The most efficient way found is to fully or partially cover the pond surface with a material made usually of high-density polyethylene (HDPE) or polypropylene (PP). The pond cover serves as a way to capture the gas generated from anaerobic digestion. Covers are usually designed to extend through the pond’s perimeter where it is either placed in a trench or held in place by means of a concrete slab. After the biogas is captured, it is collected by perforated pipes located below the cover. From the pipes, the biogas is removed from the cover by a vacuum (e.g., centrifugal fan) (NIWA 2008). Several authors have recorded the application of covers to capture biogas in municipal wastewater treatment systems. DeGarie et al. (2000) discussed the implementation of a three-layer cover consisting of geomembrane, polyform, and HDPE in Melbourne (Australia). The biogas cover was placed on the anaerobic lagoons in the wastewater treatment plant. Shelef and Azov (2000) constructed a waste stabilization pond system in the Negev desert of Israel. The pond treatment system consisted of anaerobic ponds, stabilization ponds, rock filters, and stabilization reservoirs. The authors included a cover on the anaerobic pond.

There are some points that need to be considered when recovering biogas from a pond. One of the most important is cost. The associated costs for biogas recovery include construction costs of the pond, capital and operation and maintenance costs for gas purification such as gas scrubbing, any capital and operation and maintenance costs to apply biogas for other uses, and the cost for cover design (Craggs 2004). Other potential design considerations include sludge management and the maintenance of a proper organic removal with biogas recovery (DeGarie et al. 2000). Optimizing the pH, nutrients, temperature, organic loading, and retention time are also important because it will assist in producing an effective biogas system (Kaewmai et al. 2013). These and many other considerations must be addressed when attempting to recover biogas from a pond.

In summary, waste stabilization ponds are capable of producing greenhouse gases, particularly methane. However, applying techniques such as pond covers can mitigate the emission of greenhouse gases and provide a viable source of energy.

Costs

The cost of an oxidation pond is contingent on the year and the particular country where it is to be built. This is because labor and material costs are not uniform around the world. Nevertheless, there are various analyses available to determine the feasibility of installing oxidation ponds. As with any treatment project, the major costs are capital costs (construction costs) and operation and maintenance (O&M) costs. Examples of capital costs include construction, administration/legal, land, structures, and architecture/engineering (A/E) fees, while energy is the primary operation and maintenance (O&M) cost. Cost data to build an oxidation pond facility in the USA is presented below.

There are two heavily cited sources for construction cost data in the USA—the Environmental Protection Agency (EPA) and the World Bank. In 1978, the EPA compiled construction costs based on data collected from oxidation pond use in Kansas City/St. Joseph, Missouri. The initial costs of an oxidation pond include 15 different parameters. Results from the EPA study conclude that oxidation ponds have a lower cost per capita as compared to primary and secondary treatment when considering populations between 100 and 100,000. The study also finds that estimated capital costs ranged between $0.20 and $1.00/population equivalent/year (Gloyna 1971). Recently, the EPA published updated construction cost data for the year 2006. In this publication, the EPA states that this data can be calculated for any US city. This is accomplished by multiplying the cost and the ratio of the Engineering News Record Construction Cost (ENR CC) index for a given city by the primary operation and maintenance (O&M) cost. Cost data to build an oxidation pond facility in the USA is presented below. The ENR CC index is for Kansas City in 2006. The ENR CC indexes are accessible at http://www.enr.com (USEPA 1983). In 1983, the World Bank published data comparing the capital and operation and maintenance costs of oxidation ponds with other natural treatment methods such as aerated lagoons, oxidation ditches, and biological filters. The study calculates capital costs by totaling the land, earthworks, structure, and equipment costs (Arthur 1983). Results from this report estimate that the capital costs of an oxidation pond totaled 7.3 million US$, while annual operation costs were $50,000/year. Furthermore, the report discovers that oxidation ponds have the lowest capital and operational costs as compared to other natural treatment methods (Arthur 1983; Varon and Mara 2004). Table 7 provides an example of costs between the three natural treatment methods.

Table 7 Capital and operation costs for natural wastewater treatment methods (Arthur 1983; Varon and Mara 2004)

On the other hand, the Water Environmental Federation (WEF) published data to approximate the cost of an oxidation pond for a residential area. The WEF conclude that the size of the population appropriates the value of the oxidation pond. For example, the $7.3 million dollar estimate would be at the higher end of treatment for a population of about 250,000. Considering that many oxidation ponds would be used for smaller communities, the total costs, including capital and operation and maintenance, can range between $316,400 for 20 homes and $4.7 million for 200 homes (WEF 2010) or approximately $2600–$7600 per home (USEPA 2002).

Modeling

When evaluating the performance of a waste stabilization pond, it is imperative to consider additional factors that impact the performance of the pond beyond the mere parameters that have been previously discussed. One of the best ways to make the determinations is by using modeling software. Although its popularity began in the mid-1990s, computational fluid dynamics (CFD) has evolved parallel to the advancement of computer technology. CFD models the performance of the pond in removing nutrients, BOD, sedimentation, and pathogens. CFD can vary with meteorological conditions, pond orientation, and design adjustments (Sah et al. 2012). CFD benefits the researcher insomuch as he or she is able to determine how varying the effects of conditions within waste stabilization ponds would affect the performance of removing various constituents. This is beneficial whenever the conditions are unfavorable for sampling (Karteris et al. 2005).

Various authors discuss the significance of the use of CFD in its ability to analyze treatment performance. Wood et al. (1995) initiated the use of CFD by using two-dimensional computational fluid dynamics (2-D CFD) models for the purpose of designing an optimum treatment performance.

The attempt was to derive conclusions by trying to transfer a three-dimensional entity into two-dimensional space, without the consideration of the depth changes, turbulence-caused mechanical aeration, and the non-isothermal conditions that can potentially exist within a pond under given circumstances. An additional study by Wood et al. (1998) determined that the inlet geometry had a major impact on the water flow, concluding that models are capable of determining water flow effects by varying different parameters. Also Olukanni and Ducoste (2011) determined bacteria removal by using both 2-D CFD and optimization. The authors analyzed baffle adjusted by CFD, while optimization was used to determine the minimal construction costs of waste stabilization ponds.

CFD can incorporate various parameters such as sludge accumulation, temperature, and sunlight. Alvarado et al. (2012) determined that sludge accumulation and settling of sludge within waste stabilization ponds increases as water moves away from the inlet and the velocity decreases. Karteris et al. (2005) created a temperature model within a covered anaerobic pond under unsteady state conditions. Sweeney et al. (2007) analyzed the effects of the presence of sunlight when considering the water quality between the summer and winter months.

Recent investigations into CFD modeling have been conducted to further improve the performance of waste stabilization ponds. Alvarado et al. (2013) deduced the appropriate number of aerators to achieve proper mixing within a waste stabilization pond. The results from the study are further supported by the use of tracer studies completed on a full-scale waste stabilization pond. Hadiyanto et al. (2013) analyzed the length-to-width (L:W) ratio using dimensions from a currently operating pond in the Netherlands to investigate power consumption, dead zones, and large eddy formation. Also, the authors not only incorporate a discussion on the relationship with velocity and shear stress, but include the effects of shear stress and turbulence on the growth of microorganisms and algae.

Martinez et al. (2014) compared traditional methods of pond design with mathematical software (Matlab) to find a cost-effective facultative pond that can reduce fecal coliform and BOD. The authors examine each method based on the number of baffles and the hydraulic efficiency. Results from the study conclude that the mathematical model can reduce cost by 11 %, the area requirement by 18 %, and the hydraulic retention time by 19 days.

Lee and Cheong (2014) used numerical modeling to vary the L:W ratio, pond shape, flow rate, and depth under constant pressure and a steady state flow to understand its effects on pond flow characteristics to treat acid mine drainage (AMD). The authors found that the retention time in rectangular ponds decreased with increasing elongation. Pond depth also has an impact on the retention time. An optimum depth for a rectangular pond is 2 m given a pond area of 500 m2.

As seen within this section, modeling for waste stabilization ponds has been conducted and improved to not only consider specific individual constituents, but also model various phenomena that can occur within the system. Yet, various parameters are highlighted individually within computation models. Currently, no published work has been able to provide a complete profile of wastewater entering the system or through multiple pond systems. With the constant evolution of software, modeling waste stabilization ponds could experience further advancement. Sah et al. (2012) agreed with this sentiment. In addition, the authors recommended that upto-date full-scale data should be available to verify the accuracy of the models (Sah et al. 2012).

Oxidation ponds or waste stabilization ponds are a very effective treatment option not only as tertiary treatment, but also in areas that are not capable of having conventional domestic wastewater treatment or other technologically advanced methods, as seen in Pena et al. (2002) in Columbia. Yet, the design of an oxidation pond is congruent to the location of the pond, as loading rates will vary based on temperature and climate (Mara and Pearson 1998; Gloyna 1971).

To ensure proper treatment, the operator must avoid the possibility of effluent discharge that can contaminate the environment or jeopardize public health. There are many ways that these dangers can be avoided. First, maintain all piping and other treatment unit equipment properly, along with monitoring the conditions within the pond to provide enclosure of treated waste without exposure to the external environment or the formation of residuals. Second, evaluate pathogen presence by taking samples. This will determine if the pond system is having issues. Finally, design the pond system to produce the best efficiency based on the given standards. Computer modeling provides an effective way of confirming the best treatment necessary for the given condition. If the efficiency cannot be met by one pond, another alternative is to create a multiple-staged treatment system of ponds, or include another method of treatment for maximum results.

Computer modeling provides an effective way of confirming the best treatment necessary for the given condition. If the efficiency cannot be met by one pond, another alternative is to create a multiple-staged treatment system of ponds, or include another method of treatment for maximum results.

Conclusions

Waste stabilization ponds have demonstrated the capabilities of being a viable treatment technology, specifically in small communities and developing countries because of their inexpensive maintenance and simple design. As the worldwide water crisis increases, wastewater effluent reuse, specifically from waste stabilization ponds in some fashion, will continue to increase (Mara 2012).

Two recommendations will need to be considered for the purpose of expanding this treatment technology. First, reevaluate how the treatment efficiency relates to the corresponding treatment standards for the purpose of effluent reuse. WHO has published guidelines for wastewater reuse in a four-volume publication titled: Guidelines for the safe use of wastewater, excreta and greywater in agriculture and aquaculture (WHO 2006). This document outlines standards that are necessary to ensure that the effluent from the pond is suitable for use in these applications, a very important factor in the current attempt to advocate pond wastewater as a viable alternative. The efforts to implement WHO’s guidelines will assure both citizens and governmental agencies that human health and safety is a top priority. Modeling software can be used as a tool that will provide the engineer an opportunity to design a pond that will comply with these standards. Second, retrofit current infrastructure and add stations for fuel production can provide a return on the investment when transitioning waste stabilization ponds for use in larger communities. However, biofuel production will depend on the economic viability of recovery. Despite many technological advances, the main challenge is overcoming the preference of using conventional treatment methods such as activated sludge and trickling filters to comply with treatment standards. Nevertheless, future research addressing the concerns with this section, along with those made throughout the course of this text, may persuade designers and treatment operators to reconsider their stance of minimizing the use of oxidation ponds.