Skip to main content
Log in

Modeling the Temperature Pattern of a Covered Anaerobic Pond with Computational Fluid Dynamics

  • Published:
Water, Air, and Soil Pollution Aims and scope Submit manuscript

Abstract

This paper presents the development of a 3D computational fluid dynamics (CFD) model of a covered deep anaerobic pond treating raw sewage. The model was based on an unsteady-state laminar flow which was solved in accordance with the finite volume method and simulated the hydrodynamic pattern and thermal energy balance of the anaerobic pond throughout a year of operation. The model input included hourly ambient air temperature, monthly soil temperature profile, daily influent wastewater temperature and velocity, which were incorporated through an external routine in C++. Numerical simulation was validated by temperature measurements from the experimental pond. The mean relative error and correlation factor out of 164 temperature values of the simulated pond, in comparison with the experimental one, was 9.34% and 0.91, respectively. The average temperature of the simulated pond throughout the experimental period was 18.9 C. The validated 3D thermal model can be used as a tool for assessing and evaluating the impact of various design modifications (changes in construction material, adding insulation, installing a heat exchanger, etc.) on the thermal behaviour of an anaerobic pond, aiming at its average temperature increase which will, in turn, positively affect its organic removal performance. The thermal model presented, is the first stage of a complete anaerobic pond model which will include wastewater quality transport and basic biochemical reaction mechanisms of the anaerobic decomposition process present in an anaerobic pond. The complete anaerobic pond model will be able to predict the effluent COD of the pond.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Anderson, J.: 1995, Computational Fluid Dynamics, McGraw Hill, New York, 545 pp.

    Google Scholar 

  • Baleo, J., Humeau, P. and Cloirec, P.: 2001, ‘Numerical and experimental hydrodynamic studies of a lagoon pilot’, Water Res. 35(9), 2268–2276.

    Article  CAS  PubMed  Google Scholar 

  • Do-Quang, Z., Cocks, A., Line, A. and Roustan, M.: 1999, ‘Computational fluid dynamics applied to water and wastewater treatment facility modeling’, Environ. Eng. Policy 1, 137–147.

    Article  Google Scholar 

  • Flokas, A.: 1997, Meteorology and Climatology (in Greek), Aristotelian University of Thessaloniki, Thessaloniki, Greece, 465 pp.

    Google Scholar 

  • FLUENT Inc.: 1999, FLUENT 5-Getting started, 98 pp.

  • Gupta, R., Rai, S. and Tiwari, G.: 1988, ‘An improved solar assisted biogas plant (fixed dome type): A transient analysis’, Energy Conversion Manage. 28(1), 53–57.

    Article  CAS  Google Scholar 

  • Karama, A., Onyejekwe, O., Brouckaert, C. and Buckley, C.: 1999, ‘The use of computational fluid dynamics (CFD). Technique for evaluating the efficiency of an activated sludge’, Water Sci. Technol. 39(10–11), 329–332.

    Article  Google Scholar 

  • Laine, S., Phan, L., Pellarin, P. and Robert, P.: 1999, ‘Operating diagnostics on a flocculator-settling tank using FLUENT CFD software’, Water Sci. Technol. 39(4), 155–162.

    Article  Google Scholar 

  • Lettinga, G., Rebac, S. and Zeeman, G.: 2001, ‘Challenge of psychrophilic anaerobic wastewater treatment’, Trends Biotech. 19(9), 363–370.

    Article  CAS  Google Scholar 

  • Mara, D., Pearson, H., Alabaster, G. and Mills, S.: 1997, An evaluation of waste stabilization ponds in Kenya, Research Monographs No. 11, Department of Civil Engineering, University of Leeds, Leeds, UK, 109 pp.

    Google Scholar 

  • Mara, D. D.: 2000, ‘The production of microbiologically safe effluents for wastewater reuse in the Middle East and North Africa’, Water Air Soil Poll. 123(1), 595–603.

    Article  CAS  Google Scholar 

  • Papadopoulos, A., Parisopoulos, G., Papadopoulos, F. and Karteris, A.: 2003, ‘Sludge accumulation pattern in an anaerobic pond under Mediterranean climate’, Water Res. 37(3), 634–644.

    Article  CAS  PubMed  Google Scholar 

  • Pena, M., Rodriquez, J., Mara, D. and Sepulveda, M.: 2000, ‘UASBs or anaerobic ponds in warm climates? A preliminary answer from Colombia’, Water Sci. Technol. 42(10–11), 59–65.

    CAS  Google Scholar 

  • Persson, J.: 2000, ‘The hydraulic performance of ponds of various layouts’, Urban Water 2, 243–250.

    Article  Google Scholar 

  • Peterson, E.: 1999, ‘Benthic shear stress and sediment condition’, Aquac. Eng. 21, 85–111.

    Article  Google Scholar 

  • Peterson, E., Harris, J. and Wadhwa, L.: 2000, ‘CFD modeling pond dynamic processes’, Aquac. Eng. 23, 61–93.

    Article  Google Scholar 

  • Salter, H., Ta, C., Ouki, S. and Williams, S.: 2000, ‘Three-dimensional computational fluid dynamic modeling of a facultative lagoon’, Water Sci. Technol. 42(10–11), 335–342.

    Google Scholar 

  • Sanjay, R.: 2000, ‘Disinfection savings through simulation’, Water 21(October), 46–47.

    Google Scholar 

  • Saqqar, M. and Pescod, M.: 1995, ‘Modelling the performance of anaerobic wastewater stabilization ponds’, Water Sci. Technol. 31(12), 171–183.

    Article  CAS  Google Scholar 

  • Shilton, A.: 2000, ‘Potential application of computational fluid dynamics to pond design’, Water Sci. Technol. 42(10–11), 327–334.

    CAS  Google Scholar 

  • Shilton, A., Glynn, D. and Phelps, P.: 1999, ‘An inside look-the potential of CFD technology’, Water 21(July–August), 37–38.

    Google Scholar 

  • Shilton, A., Wilks, T., Smyth, J. and Bickers, P.: 2000, ‘Tracer studies in a New Zealand waste stabilization pond and analysis of treatment efficiency’, Water Sci. Technol. 42(10–11), 343–348.

    CAS  Google Scholar 

  • Silva, S., Oliveira, R. and Mara, D.: 1996, Performance of Waste Stabilization Ponds in Northeast Brazil, Research Monographs No. 9, Department of Civil Engineering, University of Leeds, Leeds, UK, 120 pp.

    Google Scholar 

  • Stafford, D., Hawkes, D. and Horton, R.: 1981, Methane Production from Waste Organic Matter, CRC press, Florida, 285 pp.

    Google Scholar 

  • Tchobanoglous, G. and Schroeder, E.: 1987, Water Quality, Addison-Wesley, MA, 780 pp.

    Google Scholar 

  • Tebbut, T.: 1992, Principles of water quality control, 4th edn., Pergamon, 251 pp.

  • Toprak, H.: 1995a, ‘Removal of soluble chemical oxygen demand from domestic wastewaters in a laboratory-scale anaerobic waste stabilization pond’, Water Sci. Technol. 29(3), 923–932.

    CAS  Google Scholar 

  • Toprak, H.: 1995b, ‘Temperature and organic loading dependency of methane and carbon dioxide emission rates of a full-scale anaerobic wastewater stabilization pond’, Water Sci. Technol. 29(4), 1111–1119.

    CAS  Google Scholar 

  • Wood, M., Greenfield, P., Howes, T., Johns, M. and Keller, J.: 1995, ‘Computational fluid dynamic modelling of wastewater ponds to improve design’, Water Sci. Technol. 31(12), 111–118.

    Article  CAS  Google Scholar 

  • Wood, M., Howes, T., Keller, J. and Johns, M.: 1998, ‘Two dimensional computational fluid dynamic models from waste stabilization ponds’, Water Res. 32(3), 958–963.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Papadopoulos.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Karteris, A., Papadopoulos, A. & Balafoutas, G. Modeling the Temperature Pattern of a Covered Anaerobic Pond with Computational Fluid Dynamics. Water Air Soil Pollut 162, 107–125 (2005). https://doi.org/10.1007/s11270-005-5996-6

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11270-005-5996-6

Keywords

Navigation