Abstract
Organic polymer monolithic columns of different lengths have been prepared in 320 µm i.d. fused silica capillary by in situ radical polymerization of N,N-dimethyl-N-methacryloxyethyl-N-(3-sulfopropyl) ammonium betaine as a zwitterionic functional monomer and bisphenol A glycerolate dimethacrylate as a crosslinking monomer in the presence of porogenic solvents. The zwitterionic monolithic columns are intended for separations of polar compounds in hydrophilic interaction chromatography (HILIC). The effects of the capillary column length, from 115 to 175 mm, on separation efficiency, were investigated under HILIC conditions, using 95:5 acetonitrile in water as the mobile phase. The extra-column contributions to band broadening significantly decrease the efficiency (apparent height equivalent to a theoretical plate), especially for weakly retained samples, and increase with diminishing column length. The experimental height equivalents of theoretical plate, HETP, were corrected for the extra-column contributions, which were determined for a series of columns by extrapolation to zero column length. On a 175 mm long column, the column efficiency, HETP = 16.5 μm, measured at the optimum linear flow velocity of 0.5 mm s−1, improved to HETP = 5 µm, after correction for extra-column contributions. For more strongly retained small polar compounds, interactions with zwitterionic groups and (or) water adsorbed inside the pores decrease the column efficiency at higher flow rates.
Similar content being viewed by others
References
Alpert AJ (1990) J Chromatogr 499:177–196
Jandera P (2011) Anal Chim Acta 692:1–25
Svec F (2012) J Chromatogr A 1228:250–262
Jandera P, Urban J (2008) J Sep Sci 31:2521–2540
Svec F, Huber CG (2006) Anal Chem 78:2100–2107
Buchmeiser MR (2007) Polymer 48(8):2187–2198
Urban J, Jandera P (2013) Anal Bioanal Chem 405:2123–2131
Nischang I, Teasdale I, Brüggemann O (2011) Anal Bioanal Chem 400:2289–2304
Urban J, Svec F, Frechet JMJ (2010) Anal Chem 82:1621–1623
Urban J, Svec F, Frechet JMJ (2010) J Chromatogr A 1217:8212–8221
Staňková M, Jandera P, Škeříková V, Urban J (2013) J Chromatogr A 1289:47–57
Jandera P, Staňková M, Hájek T (2013) J Sep Sci 36:2430–2440
Jandera P, Staňková M, Škeříková V, Urban J (2013) J Chromatogr A 1274:97–106
Fountain K, Neue U, Grumbach ES, Diehl DM (2009) J Chromatogr A 1216:5979–5988
Gritti F, Guiochon G (2011) J Chromatogr A 1218:4632–4648
Gritti F, Guiochon G (2014) J Chromatogr A 1327:49–56
Jandera P (1984) J Chromatogr 314:13–36
Dinh NP, Jonsson T, Irgum K (2013) J Chromatogr A 1320:33–47
Acknowledgments
This work was funded by the Czech Science Foundation (the Grant Agency of the Czech Republic) under the project No. 206/12/0398.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published in the topical collection 20th International Symposium on Separation Sciences in Prague with guest editors Aleš Horna and Pavel Jandera.
Rights and permissions
About this article
Cite this article
Jandera, P., Staňková, M. The Effects of the Column Length on the Efficiency of Capillary Zwitterionic Organic Polymer Monolithic Columns in HILIC Chromatography. Chromatographia 78, 853–859 (2015). https://doi.org/10.1007/s10337-015-2848-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10337-015-2848-4