Hot topic: alignment in total knee arthroplasty—systematic versus more individualised alignment strategies Michael T. HirschmannJon KarlssonRoland Becker Editorial 21 April 2018 Pages: 1587 - 1588
Kinematically aligned total knee arthroplasty limits high tibial forces, differences in tibial forces between compartments, and abnormal tibial contact kinematics during passive flexion Joshua D. RothStephen M. HowellMaury L. Hull Knee 07 September 2017 Pages: 1589 - 1601
Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT Omer SlevinAnna HirschmannMichael T. Hirschmann Knee 12 October 2017 Pages: 1602 - 1609
Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty Matthew G. TeeterDouglas D. NaudieBrent A. Lanting Knee 16 November 2017 Pages: 1610 - 1617
Internal–external malalignment of the femoral component in kinematically aligned total knee arthroplasty increases tibial force imbalance but does not change laxities of the tibiofemoral joint Jeremy RileyJoshua D. RothMaury L. Hull Knee 27 November 2017 Pages: 1618 - 1628
Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty Yasuo NikiTakeo NaguraKengo Harato Knee 04 December 2017 Pages: 1629 - 1635
Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review Alfredo Schiavone PanniFrancesco AscioneMichael T. Hirschmann Knee 15 December 2017 Pages: 1636 - 1644
Modifications of femoral component design in multi-radius total knee arthroplasty lead to higher lateral posterior femoro-tibial translation Tilman PfitznerPhilippe MoewisGeorg N. Duda Knee 27 June 2017 Pages: 1645 - 1655
Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation Martijn G. M. SchotanusElke ThijsNanne P. Kort Knee 07 August 2017 Pages: 1656 - 1661
The impact of patient-specific instrumentation on unicompartmental knee arthroplasty: a prospective randomised controlled study Abtin AlvandTanvir KhanAndrew J. Price Knee Open access 22 August 2017 Pages: 1662 - 1670
Slow gait speed after bilateral total knee arthroplasty is associated with suboptimal improvement of knee biomechanics Du Hyun RoHyuk-Soo HanMyung Chul Lee Knee 28 August 2017 Pages: 1671 - 1680
Lateral parapatellar and subvastus approaches are superior to the medial parapatellar approach in terms of soft tissue perfusion Aykut KoçakAhmet ÖzmeriçKadir Bahadır Alemdaroğlu Knee 23 August 2017 Pages: 1681 - 1690
Body mass index changes after unicompartmental knee arthroplasty do not adversely influence patient outcomes Zhan XiaMing Han Lincoln LiowSeng Jin Yeo Knee 06 September 2017 Pages: 1691 - 1697
Higher physical activity and lower pain levels before surgery predict non-improvement of knee pain 1 year after TKA Nikolai KornilovMaren Falch LindbergAnners Lerdal Knee 15 September 2017 Pages: 1698 - 1708
Bi-cruciate stabilized total knee arthroplasty can reduce the risk of knee instability associated with posterior tibial slope Masaru HadaHideki Mizu-uchiYasuharu Nakashima Knee 22 September 2017 Pages: 1709 - 1716
High performance of α-defensin lateral flow assay (Synovasure) in the diagnosis of chronic knee prosthetic infections Giovanni BalatoVincenzo FranceschiniAndrea Baldini Knee 07 October 2017 Pages: 1717 - 1722
Postoperative fixed flexion deformity greater than 10° lead to poorer functional outcome 10 years after unicompartmental knee arthroplasty Jared Ze Yang YehJerry Yongqiang ChenSeng Jin Yeo Knee 09 October 2017 Pages: 1723 - 1727
Tourniquet application during TKA did not affect the accuracy of implant positioning: a randomized clinical trial Vera StetzelbergerUdo ObertackeAhmed Jawhar Knee 20 October 2017 Pages: 1728 - 1736
The medial tibial joint line elevation over 5 mm restrained the improvement of knee extension angle in unicompartmental knee arthroplasty Koji TakayamaKazunari IshidaTomoyuki Matsumoto Knee 09 November 2017 Pages: 1737 - 1742
Medial stabilized and posterior stabilized TKA affect patellofemoral kinematics and retropatellar pressure distribution differently Alexander GlogazaChristian SchröderArnd Steinbrück Knee 09 November 2017 Pages: 1743 - 1750
Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis A. J. KievitJ. G. G. DobbeM. U. Schafroth Knee Open access 25 September 2017 Pages: 1751 - 1758
Step-wise medial collateral ligament needle puncturing in extension leads to a safe and predictable reduction in medial compartment pressure during TKA Thomas HerschmillerMatthew J. GrossoJeffrey A. Geller Knee 22 November 2017 Pages: 1759 - 1766
Internal femoral component malrotation in TKA significantly alters tibiofemoral kinematics Thomas J. HeyseBilal F. El-ZayatLuc Labey Knee 11 November 2017 Pages: 1767 - 1775
Low implant migration of the SIGMA® medial unicompartmental knee arthroplasty Daan KoppensMaiken StillingTorben Bæk Hansen Knee 16 November 2017 Pages: 1776 - 1785
The location of the medial parapatellar arthrotomy influences intraoperative patella tracking Scott R. NodzoMaximilian KasparekFriedrich Boettner Knee 11 November 2017 Pages: 1786 - 1791
Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial Nienke M. KossePetra J. C. HeesterbeekKoen C. Defoort Knee 28 November 2017 Pages: 1792 - 1799
Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases Daphne A. L. SchoenmakersMartijn G. M. SchotanusNanne P. Kort Knee Open access 17 November 2017 Pages: 1800 - 1804
Increased in vivo patellofemoral loading after total knee arthroplasty in resurfaced patellae Omer SlevinFlorian A. SchmidMichael T. Hirschmann Knee 29 November 2017 Pages: 1805 - 1810
Larger range of motion and increased return to activity, but higher revision rates following unicompartmental versus total knee arthroplasty in patients under 65: a systematic review Laura J. KleebladJelle P. van der ListAndrew D. Pearle Knee 28 November 2017 Pages: 1811 - 1822
Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation B. KerensA. M. LeendersN. P. Kort Knee 27 December 2017 Pages: 1823 - 1830
Pseudo-patella baja: a minor yet frequent complication of total knee arthroplasty Giulia BugelliFrancesco AscioneStefano Giannotti Knee 23 December 2017 Pages: 1831 - 1837
Gait analysis following medial opening-wedge high tibial osteotomy Vincent MorinRégis PailhéDominique Saragaglia Knee 01 March 2017 Pages: 1838 - 1844
High tibial osteotomy accelerates lateral compartment osteoarthritis in discoid meniscus patients Jatin PrakashEun-Kyoo SongJong-Keun Seon Knee 03 February 2017 Pages: 1845 - 1850
The effects of different hinge positions on posterior tibial slope in medial open-wedge high tibial osteotomy Ho-Seung JoJin-Sung ParkSun-Chul Hwang Knee 07 April 2017 Pages: 1851 - 1858
Patella height is not altered by descending medial open-wedge high tibial osteotomy (HTO) compared to ascending HTO Matthias KrauseTobias Claus DrenckRalph Akoto Knee 17 April 2017 Pages: 1859 - 1866
Corrective osteotomies of the lower limb show a low intra- and perioperative complication rate—an analysis of 1003 patients Maximilian SchenkeJörg DickschasWolf Strecker Knee 10 May 2017 Pages: 1867 - 1872
Large correction in opening wedge high tibial osteotomy with resultant joint-line obliquity induces excessive shear stress on the articular cartilage Hiroshi NakayamaSteffen SchröterMasaru Higa Knee 22 August 2017 Pages: 1873 - 1878
Erratum to: Two doses of low-dose perioperative dexamethasone improve the clinical outcome after total knee arthroplasty: a randomized controlled study Bin XuJun MaFu-xing Pei Erratum 19 June 2017 Pages: 1879 - 1879
Erratum to: Cohen’s MRI scoring system has limited value in predicting return to play Bruce HamiltonArnlaug WangensteenJohannes L. Tol Erratum 27 February 2017 Pages: 1880 - 1880