Visualisation and modelling of renal capillaries from confocal images E. Kaczmarek OriginalPaper Pages: 273 - 277
Multi-layer imaging of human organs by measurement of laser backscattered radiation S. ChackoM. Singh OriginalPaper Pages: 278 - 284
Thermal distribution of radio-frequency inductive hyperthermia using an inductive aperture-type applicator: evaluation of the effect of tumour size and depth S. KurodaN. UchidaH. Kato OriginalPaper Pages: 285 - 290
Performance of short-time spectral parametric methods for reducing the variance of the Doppler ultrasound mean instantaneous frequency estimation H. SavaL. -G. DurandG. Cloutier OriginalPaper Pages: 291 - 297
Theoretical comparison of two interstitial ultrasound applicators designed to induce cylindrical zones of tissue ablation C. LafonF. ChavrierD. Cathignol OriginalPaper Pages: 298 - 303
Physical activity monitoring based on accelerometry: validation and comparison with video observation K. AminianPh. RobertM. Depairon OriginalPaper Pages: 304 - 308
Estimation of the dynamics of event-related desynchronisation changes in electroencephalograms J. K. HiltunenP. A. KarjalainenJ. P. Kaipio OriginalPaper Pages: 309 - 315
A chaos-based model for low complexity predictive coding scheme for compression and transmission of electroencephalogram data V. KavithaD. Narayana Dutt OriginalPaper Pages: 316 - 321
Instrumentation for the measurement of electric brain responses to transcranial magnetic stimulation J. VirtanenJ. RuohonenR. J. Ilmoniemi OriginalPaper Pages: 322 - 326
Predicting movement during anaesthesia by complexity analysis of electroencephalograms X. -S. ZhangR. J. Roy OriginalPaper Pages: 327 - 334
Deterministic properties of apnoeas in an abdominal breathing signal P. M. MaceyJ. S. J. LiR. P. K. Ford OriginalPaper Pages: 335 - 343
Investigation of the time delay between variations in heart rate and blood pressure Y. ZhaoM. YamamotoN. Katayama OriginalPaper Pages: 344 - 347
Automatic detection of the electrocardiogram T-wave end I. K. DaskalovI. I. Christov OriginalPaper Pages: 348 - 353
Linear and non-linear analysis of the surface electrocardiogram during human ventricular fibrillation shows evidence of order in the underlying mechanism R. H. ClaytonA. Murray OriginalPaper Pages: 354 - 358
Electrophysiological basis of mono-phasic action potential recordings E. J. VigmondL. J. Leon OriginalPaper Pages: 359 - 365
Assessment of aortic pressure power components and their link to overall elastic and resistive arterial properties R. BurattiniK. B. Campbell OriginalPaper Pages: 366 - 376
Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source H. GotoT. SugiuraT. Kazui OriginalPaper Pages: 377 - 380
Time-frequency methods for detecting spike activity of stomach A. AkinH. H. Sun OriginalPaper Pages: 381 - 390
Linear spectral deconvolution of catabolic plasma concentration decay in dialysis D. LiberatiF. Turkheimer OriginalPaper Pages: 391 - 395
A portable device for finger tendon rehabilitation that provides an isotonic training force and records exercise behaviour after finger tendon surgery J. G. G. DobbeN. E. van TrommelH. A. J. Molenaar Technical Note Pages: 396 - 399
An artefact desynchroniser for use with visual evoked potential stimulators L. B. BrownA. T. BarkerA. J. Wilson Technical Note Pages: 400 - 402
Mechanotransduction pathways in bone: calcium fluxes and the role of voltage-operated calcium channels A. J. El HajL. M. WalkerS. J. Publicover Cellular Engineering-Review Pages: 403 - 409
Mechanical manipulation of polymorphonuclear leukocyte plasma membranes with optical tweezers causes influx of extracellular calcium through membrane channels Å. HolmT. SundqvistK. -E. Magnusson Cellular Engineering Pages: 410 - 412