Theoretical comparison of two interstitial ultrasound applicators designed to induce cylindrical zones of tissue ablation

  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Although interstitial techniques are invasive, they are still the first-line therapeutic modalities for certain types of tumour. They are mainly relevant to tumours that are either inoperable or located so deep that access is complicated. Of the various types of radiation that can be delivered by the interstitial route, ultrasound is the most suitable for deep heating. The study compares the efficacy of two types of applicator with respect to their ability to induce cylindrical zones of coagulation necrosis. The transducer of the first applicator is tubular, whereas the second is plane and can rotate around its axis. Both have an external diameter of 4mm, are fitted with surface cooling systems and operate at 10.7 MHz and 14W.cm−2. Comparison involves mathematical modelling of ablated tissue in the targeted area by resolving the bioheat transfer equation (BHTE) using an algorithm based on finite differences. The BHTE gives a temperature value from which the thermal dose can be determined. It is shown that tissue ablation by tubular transducers is slow, and, in consequence, perfusion disturbs the heating pattern: in vivo, irradiation with a tubular transducer lasting 1081 s would be required to ablate a tissue mass with a radius of 8mm. The corresponding period using a rotating plane transducer with 20 firing angles is only 618s. The mean exposure time of each shot lasts 31±7s. Therefore perfusion would have much less impact in the case of therapy administered using a plane transducer than that using a tubular one.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Billard, B. E., Hynynen, K., andRoemer, R. B. (1990): ‘Effects of physical parameters on high temperature ultrasound hyperthermia’,Ultrasound Med. Biol.,16, pp. 409–420

    Article  Google Scholar 

  • Bioulac-Sage, P., Le Bail, B., andBaladaud, C. (1993): ‘Histologie du foie et des voies biliaires’,in Benhamou, J.P., Bircher, J., MacIntyre, N., Rizetto, M., andRodes, J. (Eds.): ‘Hépathologie clinique’ (Med. Sciences/Flammarion), pp. 12–20

  • Chapelon, J. Y., Margonari, J., Vernier, F., Gorry, F., Ecochard, R. andGelet, A. (1992): ‘In vivo effects of high-intensity ultrasound on prostatic adenocarcinoma Dunning R 3327’,Cancer Res.,52, pp. 6353–6357

    Google Scholar 

  • Chato, J. S., Gautherie, M., Paulsen, K. D., andRoemer, R. B. (Eds.) (1990): ‘Thermal dosimetry and treatment planning. Fundamentals of bioheat transfer’ pp. 1–56

  • Damianou, C. A., Sanghvi, N. T., andFry, F. J. (1995): ‘Ultrasonic attenuation of dog tissues as a function of temperature’. IEEE Ultrasonic Symposium, pp. 1203–1206

  • Diederich, C. J. (1996a): ‘Ultrasound applicators with integrated catheter-cooling for interstitial hyperthermia: theory and preliminary experiments’,Int. J. Hyperthermia,12, (2), pp. 279–297

    Article  MathSciNet  Google Scholar 

  • Diederich, C. J. (1996b): ‘Direct-coupled interstitial ultrasound applicators for simultaneous thermobrachytherapy: a feasibility study’,Int. J. Hyperthermia,12, (3), pp. 401–419

    Article  Google Scholar 

  • Fry, W. J., Mosberg, W. H., Barnard, J. W., andFry, F. J. (1954): ‘Production of focal destructive lesions in the central nervous system with ultrasound’,Neurosurg.,11, pp. 471–478

    Article  Google Scholar 

  • Hynynen, K., Dennie, J., Zimmer, J. E., Simmons, W. N., He, D. S., Marcus, F. I., andAguirre, M. (1997): ‘Cylindrical ultrasonic transducers for cardiac catheter ablation’,IEEE Trans.,BME-44, (2), pp. 144–151

    Google Scholar 

  • Lafon, C., Chapelon, J. Y., Prat, F., Gorry, F., Margonari, J., Theillere, Y., andCathignol, D. (1998a): ‘Design and preliminary results of an ultrasound applicator for interstitial thermal coagulation’,Ultrasound Med. Biol.,24, (1), pp. 113–122

    Article  Google Scholar 

  • Lafon, C., Chapelon, J. Y., Prat, F., Gorry, F., Theillère, Y., andCathignol, D. (1998b): ‘Design andin vitro results of a high intensity ultrasound interstitial applicator’Ultrasonic,36, pp. 683–687

    Article  Google Scholar 

  • Lafon, C., Prat, F., Chapelon, J. Y., Gorry, F., Margonari, J., Theillère, Y., andCathignol, D. (1999): ‘Cylindrical thermal coagulation necrosis using an interstitial applicator with a plane ultrasonic transducer.In vitro andin vivo experiments versus computer simulations’,Int. J. Hypertherm., to be published

  • Malcolm, A. L., andTer Haar, G. (1996): ‘Ablation of tissues using high intensity focused ultrasound’,Ultrasound Med. Biol.,22, (5), pp. 659–669

    Article  Google Scholar 

  • O'Neil, H. T. (1949): ‘Theory of focusing radiators’,J. Acoust. Soc. Am.,21, (5), pp. 516–526

    Article  Google Scholar 

  • Sapareto, S. A., andDewey, W. C. (1984): ‘Thermal dose determination in cancer therapy’,Int. J. Radiat. Oncol. Biol. Phys.,10, pp. 787–800

    Google Scholar 

  • Stauffer, P. R., Diederich, C. J., andSeegenschmidt, M. H. (1995): ‘Interstitial technologies’in Seegenschmiedt, M. H., Fessenden, P., andVernon, C. C. (Eds.), ‘Thermo-radiotherapy and thermo-chemotherapy’ (Springer Verlag, Berlin, Germany) pp. 279–320

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to C. Lafon.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lafon, C., Chavrier, F., Prat, F. et al. Theoretical comparison of two interstitial ultrasound applicators designed to induce cylindrical zones of tissue ablation. Med. Biol. Eng. Comput. 37, 298–303 (1999). https://doi.org/10.1007/BF02513303

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02513303

Keywords

Navigation