Pulsatile flow experiments on heart valve prostheses K. B. ChandranT. L. YearwoodH. L. Falsetti OriginalPaper Pages: 529 - 537
Delineation of the QRS complex using the envelope of the e.c.g. M. -E. NygårdsL. Sörnmo OriginalPaper Pages: 538 - 547
Apparent depression of right ventricular function after selective reduction of left ventricular inotropy: an interpretation of experimental data utilising a computer-based circulatory model H. PieneO. A. SmisethJ. V. Tyberg OriginalPaper Pages: 548 - 556
Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique K. YamakoshiA. KamiyaT. Togawa OriginalPaper Pages: 557 - 565
Microprocessor-based image processing system for dynamic foot pressure studies C. I. FranksR. P. BettsT. Duckworth OriginalPaper Pages: 566 - 572
Ensemble averaging of locomotor electromyographic patterns using interpolation R. ShiaviN. Green OriginalPaper Pages: 573 - 578
Relationship between the surface e.m.g. and muscular force G. C. RayS. K. Guha OriginalPaper Pages: 579 - 586
Improvement of the detectability of simulated pathological tremour e.m.g.s by means of demodulation and spectral analysis H. L. JournéeJ. van Manen OriginalPaper Pages: 587 - 590
Multioscillator simulator for gastrointestinal electrical activity modelling D. A. LinkensM. KhelfaG. Nicklin OriginalPaper Pages: 591 - 598
New method to calculate the renal transit time spectrum from conventional three-probe renography R. GullquistH. AbrahamsonT. Strandell OriginalPaper Pages: 599 - 602
Experiments in automatic classification of laryngeal pathology M. MezzalamaP. PrinettoB. Morra OriginalPaper Pages: 603 - 611
Analysis of resonant coupled coils in the design of radio frequency transcutaneous links N. de N. DonaldsonT. A. Perkins OriginalPaper Pages: 612 - 627
Automated apnoea detection by computer: analysis of tracheal breath sounds J. PeirickJ. W. Shepard Jr OriginalPaper Pages: 632 - 635
CARRES: système de monitoring des rythmes cardio-respiratoires et d'acquisition de données électrophysiologiques chez le nourrisson, orienté vers l'étude du syndrome de la mort subite inexpliquée du nourrisson R. BruckertF. PerrinM. Revol OriginalPaper Pages: 636 - 643
Identification of r.e.m. sleep in the mouse by measuring the body movements A. Higashi Technical Note Pages: 644 - 646
E.c.g. electrode system using closely spaced electrodes A. B. Wilkinson Technical Note Pages: 647 - 649
True r.m.s. volt/ammeters for surgical diathermy measurements during an operation S. Grimnes Technical Note Pages: 654 - 656