Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

For the noninvasive monitoring of the beat-to-beat systolic and diastolic pressure and pressure waveform in the human finger, a new automated instrument was designed. This measurement is based on a principle called the vascular unloading technique. Using a hydraulic servocontrol system, the vascular volume change caused by intra-arterial pressure change can be compensated by applying counter pressure to maintain a constant vascular volume in the unloaded state. In this state the controlled counterpressure instantaneously follows the intra-arterial pressure. In this instrument all the necessary procedures, such as the setting of the reference value for the servocontrol, control of the servogain, processing and displaying of the data on a recorder, were carried out automatically. The simultaneous comparison of data with direct measurements and a few examples of the indirect pressure recordings by this instrument are shown and the principles, operation and evaluation of this method are described. This instrument was shown to permit the nonivasive and accurate tracking of instantaneous arterial pressure and to perform acceptably over a wide range of arterial pressure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Alexander, H., Cohen, M. L. andSteinfield, L. S. (1977) Criteria in the choice of an occluding cuff for the indirect measurement of blood pressure.Med. & Biol. Eng. & Comput.,15, 2–10.

    Google Scholar 

  • Cobbold, R. S. C. (1974)Transducers for biomedical measurement: principles and applications. John Wiley & Sons, New York, 486.

    Google Scholar 

  • Geddes, L. A. (1970)The direct and indirect measurement of blood pressure. Year Book Medical Publishers, Chicago, 196.

    Google Scholar 

  • Marey, E. J. (1876) Pression et vitesse du sang. InPhysiologique experimentale vol. 2,Masson, G. (Ed.), Paris.

  • Penaz, J. (1973) Photoelectric measurement of blood pressure, volume and flow in the finger. Digest 10th Internt. Conf. Med. Biol. Engng., 104.

  • Pressman, G. L. andNewgard, P. M. (1963) A transducer for the continuous external measurement of arterial blood pressure.IEEE Trans.BME-10, 73–81.

    Google Scholar 

  • Ramsey, M. III (1979) Noninvasive automatic determination of mean arterial pressure.Med. & Biol. Eng. & Comput.,17, 11–18.

    Google Scholar 

  • Shapiro, D., Greenstadt, L., Lane, J. D. andRubinstein, E. (1981) Tracking-cuff system for beat-to-beat recording of blood pressure.Psychophysiol.,18, 129–136.

    Google Scholar 

  • Shirer, H. W. (1962) Blood pressure measuring methods.IRE Trans.,BME-9, 116–125.

    Article  Google Scholar 

  • Smith, C. R. andBickely, W. H. (1964)The measurement of blood pressure in the human body. SP-5006, NASA, 1–34.

  • Stein, P. D. andBlick, E. F. (1971) Arterial tonometry for the atraumatic measurement of arterial blood pressure.J. Appl. Physiol.,30, 593–596.

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., andTogawa, T. (1979) Indirect measurement of instantaneous arterial blood pressure in the rat.Amer. J. Physiol.,237, H632-H637.

    Google Scholar 

  • Yamakoshi, K., Shimazu, H. andTogawa, T. (1980) Indirect measurment of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.IEEE Trans.,BME-27, 150–155.

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., Shibata, M. andKamiya, A. (1982a) New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part I: model experiment.Med. & Biol. Eng. & Comput.,20, 307–313.

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., Shibata, M. andKamiya, A. (1982b) New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2: correlation study.,20, 314–318.

    Google Scholar 

  • Yelderman, M. andReam, A. (1979) Indirect measurment of mean blood pressure in the anesthetized patient.Anesthesiol.,50, 253–256.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yamakoshi, K., Kamiya, A., Shimazu, H. et al. Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique. Med. Biol. Eng. Comput. 21, 557–565 (1983). https://doi.org/10.1007/BF02442380

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442380

Keywords

Navigation