Skip to main content
Log in

Microprocessor-based image processing system for dynamic foot pressure studies

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A microprocessor-based system is described for data capture and analysis of dynamic foot pressure images. A run-length encoding video digitiser captures up to 32 frames at a rate of 25 per second and stores the data in memory. These data are displayed on a colour monitor and can be analysed to produce pressure against time curves or printed or plotted as isopressure contour plots.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Betts, R. P., Franks, C. I. andDuckworth, T. (1980a) Analysis of pressures and loads under the foot, Part 1: Quantitation of the static distribution using the PET computer.J. Clin. Phys. Physiol. Meas.,1, 101–112.

    Article  Google Scholar 

  • Betts, R. P., Franks, C. I. andDuckworth, T. (1980b) Analysis of pressures and loads under the foot, Part 2: Quantitation of the dynamic distribution.,1, 113–124.

    Article  Google Scholar 

  • Betts, R. P., Franks, C. I., Duckworth, T. andBurke, J. (1980c) Static and dynamic foot pressure measurements in clinical orthopaedics.Med. & Biol. Eng. & Comput.,18, 674–684.

    Article  Google Scholar 

  • Betts, R. P. andFranks, C. I. (1980) A video tape recorder to video digitiser synchronising circuit.Electronic Engineering,52, (638), May, 31.

    Google Scholar 

  • Boulton, A. J. N., Hardisty, C. A., Betts, R. P., Franks, C. I., Worth, R. C., Ward, J. D. andDuckworth, T. (1983) Dynamic foot pressure and other studies as diagnostic and management aids in diabetic neuropathy.Diabetes Care,6, 26–33.

    Google Scholar 

  • Chodera, J. (1957) Examination methods of standing in man. FU-Czechoslovakian Academy of Sciences, Prague, Vols. 1–3.

    Google Scholar 

  • Duckworth, T. andBetts, R. P. (1978) The varus foot in spinal dysraphism.Zeitschrift fur Kinder-Chirurgie und Grezgebiete, Band25, Heft, 4, 375–386. (Proceedings of the Olso meeting of the Society for Research into Hydrocephalus & Spina Bifida, 1978.)

    Google Scholar 

  • Duckworth, T. andBetts, R. P. (1980) The valgus foot in spinal dysraphism.Zeitschrift fur Kinder-Chirurgie, Band31, Heft 4, 402–413. (Proceedings of the Gottingen meeting of the Society for Research into Hydrocephalus and Spina Bifida, 1980.)

    Google Scholar 

  • Duckworth, T., Betts, R. P. andFranks, C. I. (1982) The measurements of pressures under the foot.Foot & Ankle,3, 130–141.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Franks, C.I., Betts, R.P. & Duckworth, T. Microprocessor-based image processing system for dynamic foot pressure studies. Med. Biol. Eng. Comput. 21, 566–572 (1983). https://doi.org/10.1007/BF02442381

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442381

Keywords

Navigation