Background

Recently, microrobots, which are capable of performing microscopic motions, have been drawn significant attentions in various fields of nanotechnology and biomedical technology due to its micro-size and controllability. Especially, due to its small size, applications of microrobots including active drug delivery system for therapeutic treatments and also a tiny lens at the tip of endoscope for diagnostic care in human body have been recently proposed [1, 2]. Microrobots, however, need suitable microactuators for propulsion and one of the major challenges are sophisticated fabrication or assembly of a proper micro and nanoscale actuator for the microrobot. In the meantime, various types of actuators have been actively investigated considering their reliability, controllability and limited size for their potential applications to these microrobots, such as an electrostatic actuator [3, 4] and a piezoelectric actuator [5], etc. While these actuators can provide a fast and controllable movement in precise manner inside human body (low Reynolds number environment in terms of fluid dynamics [6, 7]), they either create inherent bubbles due to electrolysis, require continuous onboard power supply or are applicable only in transparent environment. Therefore, for the past few years, bio-actuator based microrobot approaches have been widely studied for resolving these problems.

Bio-actuators have many advantages over artificial actuators because of self-propulsion or producing kinetic energy from ambient for their motions [8]. However, these bio-actuators inevitably have complex incubation procedures, and difficulty to integrate into objects to be manipulated using toxic chemical substances. Thus, various types of bio-actuator possessing a non-toxic substance and self-movement with no external power has extensively been studied [9]. Among these bio-actuators, the flagellated bacteria has been actively researched because the motion of the bacteria have maximum speed up to 100 um/s, if required chemical resource are supplied under appropriate environment [10]. While a number of researches were performed on applying these active bacteria to bio-actuator, their toxicity and random motions prohibit further applications so that detoxifying the bacteria and boosting up the speed of a microrobot in desired direction are highly required [1113]. For this purpose, several researchers have developed new adhesion methods for anisotropically attaching the bacteria on the microstructures considering the directionality [14], which is the main issue of the research in bacteria-attached microrobot. While one can attach the bacteria during the fabrication of the target object [15], the bacteria can be harmed due to the toxic fabrication process and it is recommended to attach the bacteria after the objects are completely assembled. Behkam et al. demonstrated S. marcescens flagellated chemotactic bacteria as bio-actuator for the propulsion of polystyrene microbeads by oxygen plasma treatment. With the aid of external electric field, the bacteria-attached micro-bead’s motility was assessed (15–30 um/s, E k  = 216.522 × 10−21 J but this number contained an electrostatic energy) where E k is kinetic energy, which is equal to the half of mass times velocity square, that the bacteria-attached microroparticle possessed so that E k can consider both the motility and mass effects simultaneously [11]. Park et al. also demonstrated a conjugation method based on streptavidin/biotin reagents for strong attachment of the bacteria and microstructures by a high-affinity interaction. The bacteria-attached microparticle’s motility were verified using chemotactic behavior to tumor cell (0.5 um/s, E k  = 0.0147 × 10−21 J) [16]. Sahari et al. reported anisotropic attaching the bacteria by coating poly-l-lysine to surface of the polystyrene particles with different shapes (4.0 um/s, E k  = 0.941 × 10−21 J) [17]. Martel et al. researched a method by attaching magnetotactic bacteria to the polystyrene microbeads by immune response, producing the magnetic-guided auto-propelled microrobots. By applying electromagnetic field to the microrobot, the motility and direction was controlled (21 um/s, E k  = 25.936 × 10−21 J) [18]. However, these aforementioned methods harm the bacteria, has difficulty to modify the surface, and are often toxic for human body. Therefore, a new methodology for an effective directional control of bacteria-attached microrobot without less toxicity is required.

In this paper, we proposed a simple, but effective microfluidic structure for anisotropical absorption of bacteria to microparticles for demonstrating bacteria integrated microrobot. By flowing attenuated Salmonella typhimurium bacteria into the microfluidic channel, hydrophobicity of microparticles made of biodegradable polycaprolacton (PCL) enabled a quick bacterial absorption (<100 s) without any toxic adhesive substance or chemical modification. Moreover, the bacteria were attached only at the surfaces of microcubics facing against the flow direction and the rest of the surfaces were free from the absorption, since Laminar flow can eliminate any backflow or vortical flow. The maximum motility of the bacteria-attached microparticle was measured to be ~ 5 um/s (E k  = 58.952 × 10−21 J) by chemotaxis which is comparable to prior state of art technologies.

Methods

Device fabrication

A silicon master for poly-dimethyl siloxane (PDMS) mold was prepared as following. A 4-inch wafer was cleaned in piranha solution (H2SO4: H2O2 = 4:1) to remove residual organics. SU-8 2050 (MicroChem, USA) photoresist was spun (JSP4A, JD Tech, Korea). The coater parameters were set depending on the target height, for example, 500 rpm of 15 s for spreading and 4000 rpm of 40 s for conformal coating in case of 35 um, etc. After soft bake for 3 min at 95 °C, the layer was exposed by ultraviolet (UV) of 365 nm wavelength for 6.4 s (160 mW) using MA-6 Aligner (Karl-suss, Germany). After post baking at 95 °C for 6 min, the wafer was cooled down slowly to room temperature. Then the pattern was developed in PEGMA developer for 10 min. After rinsing with iso-propyl alcohol, hard bake was performed at 120 °C for 5 min. For a PDMS cast, we followed the general soft-lithographical fabrication processes [19]. Briefly, PDMS (Sylgard 184 Silicone elastomer kit, Dow Corning) base was mixed with a curing agent at 10:1 and bubbles were removed by vacuum jar for 1 h. After pouring the solution onto the master, it was cured in an oven at 75 °C for 4 h. Cured PDMS piece was peeled off from the master and cut into each device. Punching out the inlet and outlet holes was followed. Then PDMS piece and slide glass were bonded by oxygen plasma treatment (Femto Science, Korea).

Microparticle fabrication

The biodegradable PCL micro chamber was prepared using the x-ray-lithography-based microfabrication method [20]. Briefly, a 10 % PCL solution in di-chloro-methane (DCM) was poured on a silicon wafer and coated at 1400 rpm to obtain PCL film with the thickness of 15 um. A lamination process was used to form the double layered PCL solid film with the thickness of 30 um [21]. X-ray synchrotron irradiation was performed at Pohang Accelerator Laboratory (PAL), Korea to pattern the PCL film with 30 um × 30 um cubic microparticles. A 45 % (w/v) potassium hydroxide (KOH) solution was used to separate the pattered PCL microparticles from the substrate. The microparticles were dispensed in deionized water so that the number density of the microparticles can be 104 ea./mL.

Bacterial culture

The random speed and motions of bacteria are controlled by the taxis characteristics [22]. Among various taxis mechanisms, chemotactic characteristics have been recently studied [23] because a target site (e.g. cancer site) often released a specific chemical for bacteria to be followed. S. marcescens and S. typhimurium especially shows the directional movement toward chemo-attractant by flagella motor [24, 25]. Bacteria used in this work were attenuated S. typhimurium (SHJ2037) since it has chemotactic behavior toward a breast cancer site and also has shown a reasonable safety level by several clinical trials [26]. In addition, the attenuated S. typhimurium is characterized by fluorescence expression for easy tracking of their movements. S. typhimurium were inoculated in solid Luria–Bertani broth medium (LB medium) consisted of 500 mL DI water, 7.5 g agarose powder (DUKSAN, Korea), 5 g sodium chloride (NaCl, DUKSAN, Korea), 5 g tryptone (Becton, Dickinson and Company, USA) and 2.5 g yeast extract (Becton, Dickinson and Company, USA). The solid LB medium was incubated at 37 °C for overnight since it is easier to get highly active bacteria in solid LB than in liquid LB. From the inoculated solid LB medium, one bacterial colony was picked and cultivated in the 10 mL of liquid LB medium that contained 50 ug/mL of Kanamycin and Ampicillin. Then the bacteria was incubated at 37 °C on shacking incubator at 120 rpm for 3 h. The engineered S. typhimurium at an optical density (OD600) of 1.0–1.5 (UV/VUIS Spectrophotometer-Optizen 2120 UV, Mechasys, Korea) were used in this experiment.

Bacteria absorption

Main microfluidic channel of device was connected with syringe pump (Harvard PHD 2000, USA) using four-port switching valve (IDEX, USA) for sequential injection and the outlet channel was linked with another syringe pump. First, the mixture of microparticles (100 ea./mL) was diluted with dimethyl sulfoxide (DMSO, DAEJUNG, Korea) and injected into the device at a flow rate of 0.1 mL/min for 10 min. DMSO reduces friction between microparticles and the surface of channel. Since DMSO has toxicity to bacteria, DI water was injected to wash out DMSO. After DMSO was completely removed, S. typhimurium was pumped into main channel at 3 uL/s. The hydrophobicity of microcubics made of biodegradable PCL enabled a bacterial absorption without any adhesive substance or chemical modification. Moreover, the bacteria can be attached only to the surfaces of microparticles facing against the flow direction and the rest of the surfaces were free from the absorption. Lastly, back-pressure from the outlet channel was applied into the main channel for releasing and collecting the bacteria-attached microparticles. All of experiments were monitored with IX51 inverted fluorescent microscope (Olympus, Japan) and the images were post processed using CellSens software (Olympus, Japan).

Chemotaxis of S. typhimurium

Aforementioned S. typhimurium was attracted by aspartate acid [27]. For evaluating the chemotactic motility, we used 10 mM of α-methyl-DL-aspartic acid (Sigma-Aldrich, USA) solution as a chemo-attractant in the flow-free microfluidic channel. The concentration of attractant was chosen as previous studies [16, 27]. Before the demonstration using the microparticles, the chemotaxis of S. typhimurium itself was tested in Y-shaped microchannel. The bacteria were injected from the left reservoir and 10 mM of aspartic acid was dropped only at bottom right reservoir. See Additional file 1. While capturing this movie, bacteria were able to be moved only by diffusion since there was no net flow from anywhere. However, the bacteria tended to move toward the bottom right reservoir and there was no reason for this movement except the chemotaxis. This video clearly showed that S. typhimurium has the chemotaxis properties.

Results and discussions

Microfluidic trapper for anisotropic bacterial absorption

Absorption concept

The main concept of the fabricating bacteria-attached microparticle is shown in Fig. 1. We designed micro-structures called “trapper” to hold the microparticles for anisotropic attachment of the bacteria. The trappers play a role as structural blocker so that they allow the bacteria attachment to the surfaces of micro-cubes facing against the flow direction and, thus, the rest of the surfaces were free from the absorption. Bacteria-attached microparticle production method using the trappers is as follows. First of all, the fluid contained microparticles are injected from the top and they are caught in trappers (Fig. 1i). The shape of trapper is designed to capture only one microparticle and residual cubes automatically flow down toward the next trapper to fill the entire array of the trappers. Next, bacteria are injected for a while from the top as well. The duration and flow rate will be discussed later on. Because microparticle made of PCL polymer has hydrophobic surface [28], these surfaces adsorb bacteria without any additional chemical or physical treatments (Fig. 1ii). Excess amount of bacteria is supplied by fluidic flow to the microparticles for conformal absorption, while previous studies usually have attached the bacteria in static conditions (i.e. without any flows). The Laminar flow also helps to prevent undesirable attachment to the backside surface of microparticles. Finally, bacteria growth medium is pumped into the channel in the opposite direction (Fig. 1iii). The stream is capable of releasing the captured microparticles by fluidic inertia and they are collected at the top inlet reservoir. Thus, our unique method has several advantages; (1) simple production with low cost due to the absence of additional chemical or electrical treatments, (2) reusability of the device since severe washing steps are not involved in this concept and (3) high scalability because one can expand the size of arrays as long as low Reynolds fluidic regime is satisfied.

Fig. 1
figure 1

Adsorption concept for anisotropic bacteria attachment

Device design

A simple straight channel device including trapper arrays in the middle was designed and fabricated as shown in Fig. 2a. The height of the channel was 40 or 70 um for microparticles of 30 um × 30 um or 50 um × 50 um, respectively. The height was larger than the size of microparticle for smooth flowing through the channel without clogging or stacking. The width of the channel was 2.0 or 2.5 mm for arranging 7–6 or 14–15 trappers in one line (Fig. 2b). The detailed shape of trapper was chevron with small gap in the middle as shown in Figs. 2c and 3-dimensional SEM image was shown in Fig. 2d. The gap between the trapper arms decreased fluidic resistance to assist comfort landing of microparticles. The horizontal (d h ) and vertical (d v ) distance between each trapper were adjusted depending the size of microparticles. d h was set to be 140 um (in the case of 50 um × 50 um microparticle) for preventing unwanted stacking of microparticles between trappers. d v was determined to be 200 um (in the case of 50 um × 50 um microparticle) through analyzing data using COMSOL multiphysics. As shown in Fig. 3a, b, this microfluidic device has a low Reynold number regime so that all streamlines persist a laminar flow, i.e. the microparticles followed the streamline for consecutive trapping from the top trapper. U 0 was the inlet velocity of sample flow. However, the microparticle had significant mass so that an inertia effect drove the microparticle to fall down straightly toward the next trapper. Likewise, the microparticle went around the occupied trapper, seeking unoccupied trapper. As a result, each trapper possessed only one microparticle, filling the entire array one by one. Maximum velocity appeared at the sides of channel will be discussed later on.

Fig. 2
figure 2

a Fabricated device, b microscopic image of the trapper array, c magnified view for 50 um microparticle trapping and d SEM image of the trapper. Horizontal (d h ), vertical (d v ) distances and height of trapper were varied depending on the size of microparticles, while the dimension of trapper itself was fixed

Fig. 3
figure 3

Numerically simulated streamlines and velocity magnitude contour plots of (a) before and (b) after capturing microparticles. Reynolds number was set to be 1. The velocity has the maximum values near both walls of microchannel

Bacteria also followed the laminar streamline to approach to the microparticle. Since excess amount of bacteria were supplied from inlet reservoir, there was a higher stochastic chance for the bacteria to contact the microparticle surface than no flow condition in previous literature. However, the flow rate should be carefully determined since the bacteria should stay around the cube for the residence time (i.e. the time requires for the absorption.)

Microparticle trapping efficiency

Various dimensions of trapper were tested to capture different size of microparticles. The trapper array of d h  = 140 um and d v  = 200 um for 50 um × 50 um microparticles and d h  = 90 um and d v  = 500 um for 30 um × 30 um microparticles were shown in Fig. 4a, b respectively. We considered all of one to one landing as “success” regardless of the alignment of microparticles, since anisotropic attachments still valid to the misaligned surface. The vacancy mainly occurred near both walls of microchannel. This was due to the flow rate near the walls was faster than the center of microchannel as predicted in Fig. 3. Due the fast velocity, the relative inertia of microparticles became smaller near the walls than at the center so that the microparticles tend to follow the streamline which just passes between trappers. Statistically, 70 ± 5 % of the trappers were able to capture the microparticles properly and ~30 % (mostly near the walls) of the trappers were unoccupied. While the success rate could be improved by adjusting a flow rate or d h and d v , etc., one crucial point of this concept was one to one trapping. If more than 1 microparticle stays on the trapper, the bacteria attached only to the out-most microparticles, leading to lower the anisotropic absorption efficiency.

Fig. 4
figure 4

Microscopic images of two different sized trappers for capturing (a) 50 um × 50 um and (b) 30 um × 30 um microparticles. The capturing status was categorized by success, foreign matter and vacancy. See Additional file 2

Anisotropic bacteria absorption

After the microparticles filled the trapper array, GFP labeled S. typhimurium were injected from the top. Figure 5a showed the snapshots during the absorption process. At first, three captured microparticles (30 um × 30 um) had almost uniform fluorescent intensity. Since the bacteria collided and were absorbed only to the two surfaces facing against the bacteria flow, the intensity of the surfaces became brighter than remaining surfaces. The intensity of the first cube started to be non-uniform from 14 s. After 50 s, the intensity was saturated. Therefore, the dynamics of absorption was a fast (or linear) absorption at the initial and saturation after a while (the graph of Fig. 5b). Randomly selected three different experimental sets (with the same experimental conditions) among a number of analysis were shown as a function of time and they followed the dynamics. We found that the saturation time for the anisotropic attachment was at most 100 s from all analyzed data sets. Compared to previous studies that took at least 5 min for attaching bacteria, for example, S. marcescens [29, 30] and V. alginolyticus [31], even more than 30 min for S. typhimurium [16, 17], our laminar flow assisted method enabled faster attachment than any previous results which relied only on a random motion based (or diffusion based) attachment.

Fig. 5
figure 5

a Fluorescent microscopic images of anisotropic bacteria absorption at 30 um × 30 um microparticles. Uniform fluorescent intensity at the initial became non-uniform during the bacteria flow was being introduced from the top. b Saturation of fluorescent intensity at the site where the bacteria were absorbed. See Additional file 3

Direct evidences of the anisotropic attachment to 50 um × 50 um microparticle were provided using SEM as shown in Fig. 6. Magnified view of various locations of the bacteria attached were shown as indicated i–iv. The contrast of bacteria was adjusted for clear visualization. They clearly showed that the bacteria were selectively attached at the front/left surface and the top/right surface in Fig. 6a, b, respectively. Counting the number of bacteria provided the number density of 0.3 and 0.11 ea./um2 from each image, leading to the surface coverage of 60 and 25 %. The maximum number density should be limited to 0.5 ea./um2 since the size of bacteria is approximately 1 um × 2 um. These results were comparable to the state of art results, for example 0.089 and 0.1 ea./um2 using S. marcescens [12, 32, 33], respectively. But, more efficiently, our methods achieved the results even without any toxic chemical processes during the absorption and with faster attachment time less than 100 s than previous studies.

Fig. 6
figure 6

SEM images of microparticles (50 um × 50 um). The bacteria were selectively absorbed at (a) front/left surface and (b) top/right surface. Inset (i)–(iv) showed the magnified image of various surfaces that confirmed the anisotropic absorption

Chemotaxis test of bacteria-attached microparticle

Salmonella typhimurium that was utilized in this work has chemotaxis toward the concentration gradient of an appropriate attractant. For measuring chemotactic velocity of microparticles, we used 10 mM aspartic acid as previous studies used [16, 27]. One representative demonstration was shown in Fig. 7 and the attractant was dropped on upper area of solution and the microparticle started to move in the direction of the concentration gradient. Images were captured every 3 s and it revealed that the microparticles initially moved at 10 um/s and decelerated. See Additional file 4. The average velocity was measured to be 5 um/s. The speed become zero and this is the critical evidence of no-residual flow. Slow down happens when the driving force become lower. A constant concentration gradient is applied for the driving force in a practical chemotaxis. However, the gradient became flat due to diffusion of one-time injected aspartic acid and thus, the traveling distance in this work was only 120 um. This distance would be extended in a practical chemotaxis since there would be a constant concentration gradient. The particle was initially placed in quiescent solution inside a 5 cm-diameter petri-dish. In such case, Reynolds number is over 100 and a residual flow, if exists, should be oscillating flow due to high inertia force. Thus, the particle must move back and forth under a residual flow, if exists.

Fig. 7
figure 7

Microscopic images of bacteria-attached microparticle movement. It moved in the direction of chemical concentration gradient. The images were captured every 3 s and overlaid. See Additional file 4

While this velocity value was considerably faster than previous bacteria-attached microparticle, one needs to have set up a proper measure, since previous studies had employed different mass (or size) of microparticles. Kinetic energy (E k  = 0.5mv2) would be the candidate to investigate the efficiency of bacteria-attached microparticle. Larger mass could reduce the velocity, but could have higher E k value. Our presenting S. typhimurium attached microparticle has E k of 58.952 × 10−21 J which is more efficient to other studies mentioned in introduction section.

Conclusions

Laminar flow assisted anisotropic attachment of S. typhimurium flagellated bacteria to the microparticles were demonstrated for a chemotactic delivery. A low cost and scalable microfluidic device was designed to trap microparticles and controlling flows upwardly/downwardly enables an anisotropic attachment of the bacteria. Direct visualizations using fluorescent intensity and SEM imaging were performed the attachment and it was measured to be less than 100 s to complete the absorption. Chemotaxis test revealed that the maximum velocity of the bacteria-attached microparticle was ~5 um/s which is comparable to the state of art researches. Besides, this method excludes any toxic fabrication steps or chemicals so that the devices is reusable. Therefore, the presenting method is highly useful for a chemotaxis delivery of microparticles such as drug delivery system if the microparticles contains a drug. While the size of microparticle (30–50 um) are far too large to pass through the circulatory system, they are still useful when injected right near a lesion, not through a circulatory system.