Background

A sound understanding of mechanical behavior requires a thorough understanding of the evolution of deformation with time. Traditionally, the study of material structure has been limited by two dimensional (2D) analyses. This approach is often inaccurate or inadequate for solving many cutting-edge problems. In addition, it is often laborious and time-consuming. We can now use three dimensional (3D) tools and analyses to resolve time-dependent (4D) evolution of a variety of important phenomena [14].

X-ray tomography is an extremely promising, non-destructive technique for characterizing microstructures in 3D and 4D. The use of high brilliance and partially coherent synchrotron light allows one to image multi-component materials from the sub-micrometer to nanometer range.

Over the years, many ex situ X-ray tomography experiments have been performed to study the behavior of materials under mechanical loading [57]. These experiments have consisted of post-mortem characterization after testing. More recently, in situ mechanical testing has become more attractive, as a means of visualizing and quantifying microstructural changes as a function of time. Experiments under tension [810], cyclic loading [1114], corrosion-fatigue [15], and creep [16, 17] have been conducted.

Several challenges exist when designing an in situ mechanical testing stage for synchrotron tomography beamlines. The stage will be on top of several motion stages which have weight limits for precise and reproducible movement. This constrains the size and weight of the motorized linear actuator. Also, since precise rotational movement is necessary for tomography, so the load frame’s weight must be distributed as symmetrically as possible about the rotational axis. In addition, the stage requires an X-ray transparent material in the scanning area which should also be able to bear the applied load without excessive deformation. Furthermore, the load train has to be precisely aligned for the smaller samples used in tomography. This becomes even more important for in situ experiments on fatigue crack growth, for example. Finally, the distance between the fixture and the detector should be sufficient enough such that there is no contact between the load bearing sleeve and the scintillator during scanning. This can potentially affect the amount of absorption (density-based) contrast, with smaller distances yielding more absorption contrast.

In this paper, we report on several in situ testing methods developed in our group at ASU in collaboration with scientists at the Advanced Photon Source at the Argonne National Laboratory. We begin by describing our initial attempts at in situ loading in tension. This is followed by a discussion of the important issues associated with alignment, both in tension and in fatigue loading. Finally, we conclude with a section on in situ experiments in corrosion and moisture environments, which carry with them a unique set of challenges.

Experimental details on X-ray synchrotron tomography

X-ray tomography was performed at the 2-BM beamline of the Advanced Photon Source (APS) at Argonne National Laboratory. The details of the tomography system at 2-BM have been described elsewhere [1820]. In all the experiments, a monochromatic beam with energy of ~ 24 keV (except in the case of corrosion-fatigue experiment, where pink beam was used and will be described later) was focused on the specimen. A scintillator screen (CdWO4 or LuAG:Ce) was used to convert the transmitted X-rays to visible light. This was coupled with an objective lens and a camera (CoolSnap K4 CCD or PCO Dimax CMOS camera) to obtain images. 2D projections were acquired at angular increments of 0.12° over a range of 180°. The tomography at one time step can be completed in about 15–20 minutes when a monochromatic beam is used. These 2D projections were then input into a filtered back-projection reconstruction algorithm (Shepp-Logan filter) to obtain 3D information.

Tensile and fatigue behavior

Our initial in situ loading stage used to perform tensile tests is shown in Figure 1. The stage was designed to be less than 2 kg due to the weight limit of the motion stages at the 2-BM beamline. The vertical range where the region of interest on the sample must intersect the X-ray beam is often restrictive and was between 15 mm to 40 mm. Thus, the distance from the bottom of our fixtures to the center of the sample was chosen to be 30 mm — a distance that included the base plate, sub-miniature load cell, bottom sample clamp and half the sample. In the loading stage, the specimen was clamped between the actuator and the load cell. The load cell at the bottom of the loading stage was attached to a fixed lower grip. The upper grip was attached to the stepper motor with linear actuator, which imposes a displacement on the sample to achieve the desire load. A stepper motor was chosen because it could be easily integrated with motor drives already present at the beamline. The stepper motor had a captive linear actuator capable of 8 μm per step and a total stroke of 12 mm. The load cell had a capacity of 500 N.

Figure 1
figure 1

Initialin situmechanical testing stage with no provision for alignment.

The load was transmitted from the top of the stage to the bottom through a polymer sleeve (Poly methyl methacrylate or PMMA). The PMMA material was chosen due to its transparency to X-rays. Two holes were incorporated in the PMMA sleeve to facilitate the loading of the sample. A simple linear elastic finite element analysis (Cosmos Xpress, Solidworks 2008, Concord, MA) was conducted to determine the stresses and displacements in the sleeve, as shown in Figure 2(a). The modulus of the PMMA was taken as 2.4 GPa and the Poisson’s ratio as 0.35. The displacement of the bottom face was constrained and a compressive load of 200 N was applied to the top face. The calculated stress in the region between the holes was only about 0.1 MPa. The displacement in the sleeve was also quite small, on the order of a few micrometers. In addition, experiments at the load of 200 N were conducted to determine the creep rate of the sleeve, if any, during the tomography operation of about 20 minutes (Figure 2b). A negligible displacement rate of 2.5 nm/min was obtained, showing that the displacement in the PMMA did not affect the results significantly.

Figure 2
figure 2

Finite element modeling of in situ mechanical testing system. (a) Modeling of displacement and stress in PMMA sleeve. (b) Experimental measurements of displacement in sleeve, at maximum load, for time required for tomography. Both stresses and measured displacements are negligible.

It is well known that axial alignment is critical during mechanical testing. This is particularly important due to the somewhat smaller sizes of specimens used in in situ X-ray tomography, because the bending moments can be exacerbated. Grips can have both concentric and angular (axial) misalignments. Concentric misalignment shifts the vertical axes of the grips laterally away from each other whereas angular misalignment occurs when upper grip’s loading axis is at an angle with the lower grip’s loading axis. Figure 3 shows a design that incorporates specimen alignment capability. It was designed such that concentric clamp misalignment could be minimized by translating the top clamp in two orthogonal directions with respect to the bottom clamp using the four set screws. Axial misalignment could be minimized by tilting the top clamp about two orthogonal axes with respect to the bottom clamp using the four tilt screws. The top clamp was also allowed to freely rotate about its mounting screw to self-align in the third rotational direction. In addition, a bushing was provided to reduce the lateral deflection of the actuator. The amount of stress in the specimen prior to the self-alignment was small and therefore it did not affect the crack growth behavior.

Figure 3
figure 3

In situmechanical testing stage with precision alignment fixture.

A straight and parallel alignment specimen was used for initial alignment. It was machined such that it would only fit in the upper and lower grips if they were closely aligned. The benefit of X-ray tomography is the fact that 3D data sets are available, so we used actual images from X-ray tomography for finer alignment, without having to resort to strain gauges. By applying increasing loads to the pre-cracked specimen and measuring crack opening displacements, concentric alignments could be made to reduce the contributions from cracking in modes II and III. After alignment, the x-axis misalignment was about 1.8 μm, close to zero in the y-axis, and the tilt misalignment about 0.21°, as shown in Figure 4. A symmetric crack growth front was observed when alignment was performed compared to misaligned condition, as shown in Figure 5. It can be seen that with misalignment, the crack grows much further on the right side of the specimen whereas the crack is quite symmetric after alignment.

Figure 4
figure 4

Two dimensional (2D) X-ray tomography slices showing types of misalignment (a) crack growing into the plane, (b) side surface of the specimen and (c) 3D rendering showing axial and angular misalignment.

Figure 5
figure 5

Comparison of crack profile (through thickness) before and after alignment. Note that the crack front is relatively symmetrical after alignment.

A few limitations of the loading stage include the maximum cyclic frequency of 2 Hz and the maximum load of only 500 N. Also, given that the fixture must rotate 180 degrees, and that it has a load bearing sleeve, 50 mm was the closest distance our samples could safely be from the scintillator without hitting it - a distance that yields significant phase contrast when using 24 keV X-rays (produced by a bending magnet).

Using the second loading stage shown in Figure 3, in situ fatigue crack growth tomography was performed on AA7075-T651 samples [12, 13]. The fatigue crack growth rates obtained from these experiments [12, 15] were comparable to published data by others [21]. The errors in the ∆K (stress intensity factor range) measurements were up to a maximum of only 7% due to error in measurement of force. The crack lengths can be measured accurately with an error of 1–2 pixels, the effect of which was very small in the crack growth rates (da/dN) and ∆K measurements. To achieve higher resolutions in tomographic reconstructions, the width of our samples was chosen to be about 2.8 mm to achieve a desired resolution of 2 μm. A single edge-notched (SEN) geometry was chosen for these experiments because a CT specimen would be too wide to fit into a 3 mm field of view (necessary to achieve a 2 μm resolution), and a 3 mm wide MT specimen could not be machined precise enough to achieve symmetric crack nucleation on each side of the central hole. The experiments were performed in the Paris law regime because of the limited amount of time available at the beamline (typically three days), and because the highest cycling frequency achieved by our linear actuator was only 2 Hz.

The third generation in situ mechanical testing stage also incorporated load-control capability. Previously, the amount of displacement was manually monitored and was adjusted throughout the crack growth tests to maintain a pseudo-constant load amplitude, ΔP. The design of the third stage (Figure 6) included the ability to automatically control the actuator using feedback from the load cell. Additionally, the sample was inserted from the top of the stage rather than from the cut outs in the sleeve. The reason for this was that small cracks were observed over time near cut outs due to the combination of the applied load and the use of pink beam (used in corrosion-fatigue). Thus, a wider, shorter sleeve was used to facilitate sample loading and to increase load frame stiffness to perform fatigue tests at high R-ratios. The actuator’s stroke length was also increased to 25 mm to provide more clearance during sample loading.

Figure 6
figure 6

Third generationin situloading stage to perform mechanical testing with load-control capability and additional stiffness for higher R-ratio fatigue crack growth experiments.

We present some preliminary results on the fatigue tests at high R-ratio (R = 0.6) in Al-SiC metal matrix composites (MMCs) using the third loading stage. The effect of high R-ratio on the crack propagation in MMCs has not been well understood. A 2080 aluminum alloy (3.6% Cu, 1.9% Mg, 0.25% Zr) reinforced with 20 volume percent SiC particles (average particle size of 25 μm) was used. The composite was processed by blending SiC and Al powders, compacting the powder mixture, hot pressing, and hot extrusion (Alcoa Inc., Alcoa, PA). Details of the powder metallurgy process for fabrication of these composite materials can be found elsewhere [22]. SEN specimens were machined by EDM for the fatigue tests.

2D X-ray synchrotron tomography images showing the progression of fatigue cracking have been shown in Figure 7. The fracture of a particle ahead of the crack tip during high load ratio fatigue can be clearly seen. Figure 7a shows that the particle (circled) was not fractured when the experiment was paused for tomography after 7,000 fatigue cycles. However the particle fractured at 8000 cycles (Figure 7b) and then the crack passed through the same fractured particle as shown in Figure 7c. This provides insight into the fundamental understanding on how the fatigue crack interacts with SiC particles, and the role of particle fracture, both ahead and right at the crack tip, in controlling fatigue crack propagation at high R-ratios.

Figure 7
figure 7

SiC particle (circled) at (a) 7000 cycles, just before it fractured, (b) 8000 cycles, just after it fractured, and (c) 21000 cycles, just after main fatigue crack passes through the particle.

Corrosion-fatigue and stress corrosion cracking (SCC)

In order to study the effects of corrosion-fatigue as well as stress corrosion cracking, new designs were developed. Corrosion-fatigue experiments were performed in a liquid environment, as shown in Figure 8. The PMMA sleeve has not been shown here in order to clearly show the arrangements inside the stage. Corrosion-fatigue experiments were performed on AA7075-T651 in EXCO solution (4 M NaCl, 0.5 M KNO3 and 0.1 M HNO3). EXCO was chosen to ensure a significant amount of corrosion in the limited time available at the synchrotron beamline. SEN specimens were machined along LT orientation by EDM for the corrosion-fatigue tests. The biggest challenge in the experiment was to avoid the reaction of corrosive fluid with any part of the loading stage, especially the grips. Therefore, the material used for the bottom grip must be chemically inert to the solution while also sustaining the applied load. A polymeric PEEK (Polyether ether ketone) cylindrical grip was chosen to replace the bottom steel grip since it is chemically resistant to the solution and has good mechanical strength [23]. The bottom grip was fitted with the load cell. A rectangular hole was made at the top part of the PEEK grip to accommodate the sample. A hole was made on the side wall of the cylindrical grip to accommodate the stainless steel pin which passes through the hole made in the sample. Epoxy was added to make this a permanent and strong connection. The top part of the sample was clamped as previously described. Kapton tubing, which is also chemically inert to EXCO solution, was attached to the PEEK cylinder with wax to hold the solution around the sample during the test. The height of the Kapton tube was chosen such that the notch of the specimen was immersed in the corrosive fluid.

Figure 8
figure 8

Schematic of in situ state to perform corrosion fatigue experiments in corrosive solution. The PMMA sleeve is not shown to show the arrangements clearly.

“Pink beam”, which is a polychromatic beam with low and high energies removed from the white beam spectrum, was used during corrosion experiments, because the higher photon flux compared to a monochromatic beam allowed for significantly faster data acquisition. Thus the progression of corrosion could be documented with a higher frequency. While a typical scan with a double-multi-layer monochromatic (DMM) beam takes twenty minutes to complete, a pink beam scan can take only 0.5–1 second. Although much faster scans are technically possible using a pink beam, significant X-ray attenuation by the corrosive fluid required higher exposure times (2–3 minutes) to achieve a suitable signal-to-noise ratio.

Using the above design, we showed that the fatigue crack growth rate of AA7075-T651 was much higher in EXCO solution than in ambient air [15]. Figure 9(a) shows a 2D X-ray tomography image of the fatigue crack along with corrosion product and the hydrogen bubbles inside the crack formed due to reaction between AA7075 and the EXCO solution. As shown in Figure 9(b), the 3D reconstruction of the crack, bubbles, corrosive fluid and corrosion products was performed using commercially available software (MIMICS, Ann Arbor, MI). Corrosion products were segmented on a few slices (from the part of crack), as shown in Figure 9(b). Figure 10 shows the changes in the shape of the bubbles and the formation of a new bubble in a fatigue cycle. Formation of a new hydrogen bubble can be clearly seen at position 3 which was not present in position 2. All bubbles were squeezed as the crack closes during unloading (position 4). These results provided insights to the fundamentals of evolution of hydrogen bubbles inside a growing fatigue crack. In particular, local variations in pH cause inhomogeneous formation of reaction products and will affect crack growth.

Figure 9
figure 9

In situX-ray tomography of corrosion in aluminum alloy (a) 2D X-ray tomography slice showing hydrogen bubbles, corrosive fluid, and corrosion products, (b) 3D reconstruction of the fatigue crack (bubble + fluid) and corrosion products from selected area of the segmented crack.

Figure 10
figure 10

Loading-unloading sequence during in situ corrosion-fatigue. (a) 2D X-ray tomography images showing the formation of hydrogen bubble and the changes in morphology of bubbles in a fatigue cycle (b) corresponding fatigue cycle.

The presence of moisture in the environment is known to deteriorate the mechanical properties of high strength alloys. In order to understand the effect of moisture, in situ stress corrosion cracking (SCC) experiments were conducted in moisture, as shown in Figure 11(a). The PMMA sleeve has not been shown here for clear visualization of the arrangements inside the stage. The sample was loaded on both sides using steel grips attached to the actuator on one side and the load cell on other. To introduce moisture in the cell, an annular (ring shape) wet sponge was placed around the load cell at the base of the loading stage (a gap was provided between load cell and the sponge). Since stress corrosion cracking experiments require long time exposure of moisture, maintaining the constant humidity inside the chamber is a big challenge and is also critical to minimize the variability in results. In order to minimize the loss of moisture and to maintain constant relative humidity, the top part of the loading stage was covered with a plastic wrap as shown in Figure 11a. A humidity sensor was placed in front of the notch to measure the relative humidity throughout the test. These arrangements led to the constant humidity of 95–96% inside the system throughout the test, as shown in Figure 11b.

Figure 11
figure 11

3D in situ stress corrosion cracking experiments in moisture. (a) Schematic of in situ stage for experiments in moisture. The PMMA sleeve is not shown to show the arrangements clearly and (b) relative humidity as a function of time. The relative humidity remains constant throughout the test.

The in situ stress corrosion cracking experiment was performed on AA7075 in under-aged (UA) condition under constant load. The under-aged AA7075 was used due to the limited time available at the synchrotron beamline as it has already been established that the under-aged alloy is most susceptible to stress corrosion cracking in moisture [24]. Small SEN specimens were machined along the ST orientation by EDM for the SCC tests. Preliminary results obtained from these arrangements are shown in Figure 12, which contains 2-D X-ray tomography images of a SCC crack over time at constant load at the center of the specimen. These results show that the SCC tests in moisture can be performed by these arrangements. It should be noted that the same arrangements can be used to perform fatigue test in moisture by changing the constant load to cyclic load.

Figure 12
figure 12

X-ray synchrotron tomography images of the center of the specimen with time. The crack is growing at constant load (SCC).

Summary

In situ techniques using X-ray synchrotron tomography to understand the mechanical behavior of materials under variety of conditions have been explored. We have described several in situ loading methodologies, challenges, and solutions. The provisions for alignment led to symmetrical crack front in the second generation in situ mechanical testing stage. The third generation in situ loading stage provided load-control capability and additional stiffness to perform high R-ratio fatigue crack growth experiments. These loading stages were used for mechanical testing (monotonic and cyclic loading) in ambient air as well as in corrosive environments such as EXCO solution or moisture.