1 Introduction

Organic acids, such as acetic, lactic propionic and butyric acid, can be particularly aggressive to cementitious materials. It is especially significant, as they can often come into contact with agricultural infrastructure and sewage systems [1, 2]. Despite organic acids often being described as weak acids compared with strong mineral acids (e.g. sulfuric and hydrochloric acids), the attack on cementitious materials is not necessarily less aggressive. This is due to buffer effects (i.e. slower increase in the pH of the acid solution for weak acids allowing increased degradation potential) and the high solubility of the organic salts produced following organic acid attack [3,4,5,6]. In agriculture, organic acids occur from a range of sources including animal feed [7,8,9], animal waste [10,11,12], anaerobic digestion [13, 14] and crop storage [15,16,17,18]. When grass is stored as winter feed for livestock, it undergoes a fermentation process converting sugar to acids thus producing silage effluent which contains acetic and lactic acids [17, 19,20,21]. Figure 1 shows typical damage observed on concrete walls in a silage effluent storage tank. At the average level of silage effluent in the tank, significant damage is visible (Fig. 1b). Large portions of cement paste and mortar have been removed and coarse aggregates have been exposed (Fig. 1c). These concrete walls have been in place for approximately 10 years and are only exposed to silage effluent for a few months per year. Despite this, significant damage has occurred and remedial works are necessary to avoid further breakdown and corrosion of steel reinforcement if the depth of cover for reinforcement has been reduced significantly. Silage effluent also poses a considerable environmental risk. If it leaks into watercourses it can have a detrimental effect on aquatic life due to its high biochemical oxygen demand [22]. Therefore, silage effluent storage facilities need to be watertight to ensure no environmental contamination occurs. Such pollution can incur significant financial penalties alongside the cost of repairing or reconstructing damaged systems which allowed the silage effluent to escape [22].

Fig. 1
figure 1

Photograph of a silage effluent storage tank, b concrete wall showing damage around average effluent level and c damaged concrete close up

In sewage systems, biogenic sulfuric acid is typically formed and known to be corrosive to concrete. However, the organic fraction of sewage also commonly contains volatile organic acids such as acetic, propionic and butyric acid [2, 23]. The wine, sugar and dairy industries also produce a wide range of organic acids which are corrosive to cementitious materials [24]. Therefore, the organic acid resistance of a relatively new class of fly ash geopolymer binders is of upmost importance in several industries.

Fly ash geopolymers are ceramic-like materials produced by the chemical activation of an aluminosilicate source such as fly ash with alkali to form a hardened binder [25,26,27,28,29]. The most commonly used chemical activators are alkali hydroxide/silicate solutions or a combination of both. The chemical structure of fly ash geopolymers is similar to that of the zeolite except they are amorphous [27]. Geopolymerisation models have been proposed by Fernandez-Jimenez et al. [30] and Duxson et al. [31]. Both models describe dissolution of the aluminosilicate source due to the high pH of the alkali solutions. This leads to the formation of Si-rich and Al-rich gels, followed by reorganising and polycondensation increasing network connectivity and resulting in the three-dimensional aluminosilicate network commonly attributed to geopolymers [30,31,32,33].

Fly ash is a residue obtained from coal combustion in coal-fired electricity power stations [34]. On the other hand, the production of traditional Portland cement is an energy intensive process involving the calcination of limestone at high temperatures emitting huge amounts of CO2 [35, 36]. In fact, the production of 1 tonne of Portland cement emits approximately 0.8 tonnes of CO2, which varies slightly depending on the efficiency of the production facility [37,38,39].

To date, the majority of research carried out on the acid resistance of fly ash geopolymers has focused on mineral acids such as hydrochloric, sulfuric and nitric acid [40,41,42,43,44]. A previous study by Koenig et al. [1] did study the resistance of a fly ash geopolymer mix to a solution containing various organic acids. The findings demonstrate that exposure to this acid solution resulted in an increased compressive strength and in general good resistance. This performance was attributed to the formation of anorthite in the near surface region of the fly ash geopolymer. Anorthite was formed due to the incorporation of calcium ions in the acid solution. Calcium ions appear to have been present in the acid solution because they leached from other calcium rich binders stored in the same acid solution. As Koenig et al. [1] suggest the incorporation of calcium could be a promising binder specific curing method for fly ash geopolymers. However, in service it is unlikely that organic acid solutions will contain surplus calcium ions to allow the formation of anorthite. Therefore in this study samples from each mix were stored in its own individual container to avoid other samples cross-contamination, i.e. leached ions interacting with other samples and affecting performance. This study focused on the acid resistance of two fly ash geopolymer mortars, with different alkaline activator dosages, when exposed to two organic acids, i.e. acetic and lactic acid. A range of acid concentrations have been considered to ascertain the effect of acid concentration. A comparison of performance has also been carried out with traditional Portland cement mortar. Furthermore, the organic acid resistance of equivalent paste mixes has been studied to gain an understanding of the mechanism of attack on each binder.

2 Experimental methods

2.1 Materials

Fly ash conforming to BS EN 450-1:2012 [45] was supplied by Power Minerals Ltd., Drax Power Station, North Yorkshire, UK. Portland cement, CEM I 42.5N was supplied by Quinn Cement in Northern Ireland and conformed to BS EN 197-1:2011 [46]. The oxide compositions and loss on ignition (LOI) for both fly ash and Portland cement were obtained by X-ray fluorescence and are shown in Table 1. Previous publications [47, 48] showed the main crystalline phases identified by X-ray diffraction (XRD) present in the fly ash and Portland cement. In the fly ash they are quartz, mullite and hematite, whereas in the Portland cement they are alite, belite, aluminate, brownmillerite and gypsum. The particle size distribution of fly ash, Portland cement and sand are given in Fig. 2.

Table 1 Oxide composition and LOI of fly ash and Portland cement
Fig. 2
figure 2

Particle size distribution of fly ash, Portland cement and sand

The activators used were solutions of sodium hydroxide and sodium silicate. The sodium hydroxide solution was prepared at 30% w/w by the dissolution of solid commercial grade (99% purity) sodium hydroxide which was allowed to cool to room temperature prior to sample preparation. Sodium silicate solution containing, 12.8% Na2O, 25.5% SiO2 and 61.7% H2O was supplied by Fisher Scientific.

Locally sourced sand, abundant in quartz and also containing albite, muscovite and clinochlore was used as aggregate [49]. The water absorption of the sand was 0.92 and 1.1% after 1 and 24 h, respectively. The oven dry particle density was 2695 kg/m3. Both water absorption and density were measured according to BS 812-2:1995 [50]. The sand was dried at 105 ± 5 °C for a minimum of 48 h and allowed to cool to room temperature before mixing. Laboratory grade acetic (99–100%) and lactic acid (≥ 85%) were used to prepare 0.10, 0.31 and 0.52 mol/L acid solutions for each acid type by mixing in the required proportions with distilled water. Bertron and Duchesne [21] have compiled tables showing the typical concentrations of acetic and lactic acid found in real world scenarios. These typically range between 0.02 and 0.2 mol/L. Acetic and lactic acids have dissociation constants pKa of 4.76 and 3.86, respectively at 25 °C [21].

2.2 Mix proportions

The mix proportions used are presented in Table 2. The fly ash geopolymer mixes were based on initial mix design optimisation carried out by Rafeet et al. [51,52,53,54] and Vinai et al. [55]. The Portland cement mix proportions were obtained from work carried out by Kwasny et al. [56,57,58]. The paste content of all mortar mixes was fixed at 50% and the equivalent pastes were identical, except without the presence of sand. The water/solid ratio was fixed at 0.37 for both fly ash mixes (FA1 and FA2) and the water cement ratio was 0.60 for the Portland cement mix (PC). The absorption water is the amount of water needed to bring the sand to saturated surface dry condition. The total added water is the total amount of water needed plus the absorption water, less the water contained within activating solutions. The 28 day compressive strength of FA1 was 21.5 MPa whereas the compressive strength of FA2 and PC were similar, 55.5 and 53.0 MPa, respectively. FA1 is suitable for low strength applications whereas FA2 and PC are suitable for high strength applications. Alkali dosage and alkali modulus were the parameters used to proportion the quantity of each activating solution used in the geopolymer mixes. The alkali dosage is defined as the percentage of Na2O in the binder and the alkali modulus is the ratio of Na2O and SiO2 (sometimes referred to as silica modulus). FA1 had an alkali dosage of 7.5% and an alkali modulus of 1.25. FA2 had an alkali dosage of 11.5% and an alkali modulus of 0.95. This resulted in an increased content of both activating solutions in FA2, particularly sodium silicate. These alkali dosages and alkali moduli were chosen based on mix optimisation carried out by Rafeet et al. [51,52,53,54] and Vinai et al. [55], aiming for 28-day compressive strength of approximately 20 MPa (FA1) and 50 MPa (FA2 and PC). FA1 had relatively low activator content and is more environmentally friendly than FA2 which had similar compressive strength as that of the PC mix.

Table 2 Mix proportions (kg/m3) for geopolymer and Portland cement mortars

2.3 Sample preparation

Both mortar and paste samples were prepared with a 10 l capacity planar-action high-shear mixer using a similar procedure as that of Kwasny et al. [58]. Firstly, the oven dried sand was placed in the mixing bowl along with half of the total added water and mixed together for 1 min. After 15 min the powder component (fly ash or Portland cement) of each mix was added. Finally, the remaining water (and activating solutions if appropriate) was added and mixing continued for 6 min before casting.

The samples were cast in two layers into 50 mm three-gang cubic moulds and each layer was compacted using a vibrating table. After casting the samples were wrapped in cling film to prevent moisture evaporation and placed in the appropriate curing conditions depending on sample type. FA1 and FA2 were cured in a laboratory oven at 70 °C for 7 days and then placed in the conditioning room at 20 ± 1 °C and 50 ± 5% relative humidity. PC was cured at 20 ± 1 °C and stored on 15 mm high spacers above 5 mm of water in sealed containers throughout where the relative humidity was > 90%. Samples were demoulded after 24 h and returned immediately to the appropriate curing conditions.

2.4 Testing procedures

Resistance to organic acid attack was determined using an accelerated method, based on the guidelines provided in ASTM C267 [59] and previous studies [47,48,49, 60]. The mass loss of 50 mm mortar cubes following immersion in acid solutions was investigated. After 21 days curing the cubes were placed into a water bath (20 ± 1 °C) until 28 days when the mass of each cube was recorded. Subsequently sets of four cubes from each were placed into plastic boxes containing acid solutions with concentrations of 0.10, 0.31 and 0.52 mol/L of acetic and lactic acid. The acid solution to sample volume ratio was maintained at approximately 0.9 throughout. Every 7 days, visual inspection was carried out, the mass of the mortar cubes was recorded and the acid solution replenished. Additionally the pH of the acid solution was recorded before replenishment. After 56 days (8 cycles), the average compressive strength was obtained by testing three cubes from each box with a constant loading rate of 50 kN/min. The loading zones were protected with softboard to reduce the effect of uneven surfaces. This method was used instead of capping or grinding to allow immediate testing following acid attack, avoiding testing delays which would have caused issues regarding intermediate sample storage conditions and drying during processing. Control samples which were not exposed to acid were also tested for comparison. The remaining fourth specimen was used to visually inspect the alkalinity loss. This was achieved by splitting the cubes and applying phenolphthalein solution on the split surface which highlights (deep pink/purple) the region where the pH is greater than approximately 9 [61,62,63].

Mercury intrusion porosimetry (MIP) was used to assess the pore structure of each mortar mix. At 28 days mortar fragments measuring approximately 8 × 8 × 20 mm were sectioned from the core of each cube using a diamond saw. Hydration/reaction was stopped by oven drying the samples for 24 h at 60 ± 1 °C, then immersing them in acetone for 4 h and subsequently drying them in a desiccator (20 ± 1 °C) for a further 24 h. The pore structure of the samples was determined using a Pascal 140/240 mercury intrusion porosimeter from ThermoFisher Scientific. The mercury contact angle was taken to be 140°.

Equivalent paste samples were exposed to the same cyclic exposure regime for 21 days (3 cycles) for the highest concentration (0.52 mol/L) of both acetic and lactic acid. Inductively coupled plasma mass spectroscopy (ICP) was used to analyse the acid solution at the end of each exposure cycle (every 7 days). At the end of 21 days exposure (3 cycles), the paste samples were used for microstructural analysis. They were compared with control pastes which were submerged in water instead of acid but otherwise processed in the same way. Powdered samples were obtained by crushing and grinding the outside layer of the paste samples in a pestle and mortar. The powders were dried in a desiccator at 35 °C for 24 h prior to analysis. X-ray diffraction (XRD) was carried out with a PANalytical X’Pert PRO diffractometer applying CuKα radiation of wavelength 1.54 Å. Diffraction patterns were collected between 5 and 65° 2θ with a step size of 0.017°. PANalytical X’Pert Highscore software with the powder diffraction file (PDF) database was used to analyse the diffraction patterns. Fourier transform infrared spectroscopy (FTIR) data was obtained using Jasco 4100 series FTIR Spectrometer with attenuated total reflectance attachment. The spectra were gathered between 650 and 2000 cm−1 wavenumber at 8 cm−1 resolution.

3 Results and discussion

The pore structure and porosity results obtained for unexposed mortar samples are discussed first followed by the findings on mass loss, compressive strength loss and alkalinity loss of mortar samples exposed to organic acids. Finally the tests carried out on paste samples are presented including assessment of leaching behaviour (pH change of acid solutions due to acid attack of mortars is also monitored) and microstructural changes due to organic acid attack.

3.1 Porosity and pore structure

Figure 3 shows the pore size distribution, while Table 3 summarises the pore structure properties obtained by MIP for each mix. It should be noted that Diamond [64] reported that MIP is not always a suitable method for the characterisation of pore size distributions in cementitious materials. This is due to the misallocation of pore sizes related to accessibility and connectivity of the pore network [64] and has been named as the ‘ink-bottle’ effect [65]. However, Diamond also acknowledged that MIP measurements are useful for comparative purposes of the pore systems in cementitious materials [64], which is the main focus of the MIP measurements reported in this study.

Fig. 3
figure 3

Differential volume of intruded mercury versus pore diameter for mortar mixes at 28 days

Table 3 Pore structure properties of mortar mixes at 28 days

FA1 had a porosity of 19.2% which was reduced to 16.9% for FA2 when the alkaline activator dosages were increased. Similarly the average pore diameter was much smaller for FA2 compared with FA1. This was likely to be due to a more complete activation of fly ash in FA2 resulting in a more dense microstructure [66, 67]. This can be explained by the nature of fly ash particles and the reaction process as discussed below. Fly ash consists of censospheres which are lightweight spherical particles that can either be hollow or contain smaller spheres called plerospheres [68,69,70,71]. The activation process begins with the dissolution of the outside layer of fly ash particles. This uncovers smaller embedded particles which then undergo consecutive dissolution. This results in the inside of larger particles being filled with reaction product, forming a dense matrix [30, 31]. This type of activation process is easily identified in FA2 as shown in Fig. 4. On the other hand, FA1 had a greater number of unreacted spherical fly ash particles (Fig. 4) compared with FA2 due to the lower activator dosages used.

Fig. 4
figure 4

SEM images of hardened paste samples of FA1, FA2 and PC (×1000)

The porosity of the PC mortar (12.0%) was lower than both FA1 and FA2 (19.2 and 16.9%) and the average pore diameter of PC (0.034 µm) was smaller than both FA1 and FA2 (0.111 and 0.043 µm). This is likely due to the more space filling calcium silicate hydrate (C–S–H) formed in Portland cement systems (Fig. 4) compared with the less dense and more porous sodium aluminium silicate hydrate (N–A–S–H) gel formed in fly ash geopolymers [54, 72,73,74,75].

3.2 Mass loss

Figure 5 shows the mass losses of FA1, FA2 and PC mortar mixes during 56 days exposure to 0.10, 0.31 and 0.52 mol/L solutions of acetic and lactic acids. Lactic acid caused increased mass losses compared with acetic acid and is likely due to the lower dissociation constant of lactic acid. Exposure to 0.10 mol/L resulted in small mass losses which were negligible for the fly ash geopolymer mixes after 56 days of testing. For PC they were 1.2 and 0.7% for lactic and acetic acid, respectively, while the mass losses for the both FA1 and FA2 mixes were less than 0.3% for both acids. Following 56 days exposure to 0.31 mol/L of each acid, slightly larger mass losses were observed, particularly for PC. They had mass losses of 5.5 and 2.8% for lactic and acetic acid, respectively. The mass losses for the FA1 and FA2 were between 0.5 and 1.2%. Exposure to 0.52 mol/L solutions of acetic and lactic acid caused larger mass losses for each mix. PC had a mass loss of 12.9% due to lactic acid and 5.0% due to acetic acid. The mass losses for FA1 and FA2 were between 0.8 and 1.8%. Furthermore, the rate of mass loss per cycle appears to be constant or increasing for PC whereas the opposite is true for the FA1 and FA2.

Fig. 5
figure 5

Mass loss of FA1, FA2 and PC mortar mixes during 56 days exposure to a 0.10, b 0.31 and c 0.52 mol/L solutions of acetic and lactic acids

The fly ash geopolymer mixes exhibited relatively similar performance, regardless of the alkaline activator dosages. However, at increased concentrations of lactic acid, FA1 had marginally larger mass losses than FA2. Additionally, the mass losses for FA1 and FA2 are much less than that of PC indicating they are less susceptible to organic acid attack.

Figure 6 shows the visual appearance of FA1, FA2 and PC mortar samples following 56 days exposure to three concentrations of acetic and lactic acids. The fly ash geopolymer mixes appear to become lighter in colour following attack by increased concentrations of both acetic and lactic acid. Apart from the colour change it is difficult to see any signs of surface deterioration. In the case of the PC, there is a visible loss of cement paste from the surface of the samples following exposure to 0.31 and 0.52 mol/L solutions. The loss of cement paste also results in the exposure of sand particles causing a rough surface to be observed. More significant cement paste loss is apparent for lactic acid exposure compared with that for acetic acid exposure. These findings are in agreement with the mass losses, i.e. lactic acid causes increased deterioration compared with similar concentrations of acetic acid, particularly for PC.

Fig. 6
figure 6

Visual appearance of FA1, FA2 and PC mortar samples following 56 days exposure to three concentrations of acetic and lactic acids

3.3 Compressive strength loss

Figure 7 shows the compressive strength of FA1, FA2 and PC mortar mixes after exposure to 0.10, 0.31 and 0.52 mol/L of acetic and lactic acids when tested at the end of the 56 day exposure regime. The compressive strength of samples kept in water (unexposed), tested at the same age as the acid attacked samples is also shown. Exposure to acid, regardless of type or concentration causes a reduction in compressive strength for each mix. Generally as the acid concentration increases the compressive strength loss also increases. Additionally, it appears that lactic acid causes a larger reduction in compressive strength compared with acetic acid. The percentage strength losses demonstrate relatively similar performance for each mix.

Fig. 7
figure 7

Compressive strength of FA1, FA2 and PC mortar mixes after 56 days of exposure to 0.10, 0.31 and 0.52 mol/L solutions of a acetic and b lactic acid. The compressive strength of unexposed samples is also shown. The values above the strength results of samples exposed to acid attack represent the percentage strength loss (i.e. their strength is compared with unexposed samples)

3.4 Alkalinity loss

Figure 8 shows photographs of the cross sections of FA1, FA2 and PC mortar samples sprayed with phenolphthalein solution. Samples were exposed for 56 days to 0.52 mol/L solutions of acetic and lactic acids. Photographs of samples kept in water (unexposed) are included for comparison. The unexposed samples appeared pink/purple across their entire cross-section which indicates that the pH was above 9.0. It is worth noting that although this shows that the pH was above 9.0 for each mix, the specific pH for each mix is not known. There may be some difference in the initial pH values due to the different composition of each mix. Previous publications from this group [48, 60] showed the evolution of the pH of water solutions during immersion in water of the equivalent pastes of these mortar mixes. Initially the pH of the water was 6.8 but increases over time during samples immersion. Eventually the pH of the water solutions became stable which may provide an indication of the pH of the pore solution of each mix. We reported that there was only a small difference between each mix, (values ranged between 11.5 and 12.5 following 7 days of immersion) [48, 60]. This suggests that the difference in the pH of the pore solution for each mix was small. However, it is expected that the pore solution of FA2 has a slightly higher pH than FA1 due to the increased alkaline activator dosages. The pH of the acetic and lactic acid solutions was relatively low (< 3.0). Therefore, the effect of the small difference in pH of each samples pore solution should be almost negligible.

Fig. 8
figure 8

Photographs of the cross sections of the FA1, FA2 and PC mortar samples sprayed with phenolphthalein solution after exposure to water (unexposed) and 0.52 mol/L solutions of acetic and lactic acids

Following 56 days exposure to acetic and lactic acid the pH of the entire cross-section of FA1 was reduced below 9.0 as no pink/purple region was observed following application of phenolphthalein solution. This suggests that the acid solution had either reached the centre of the sample or caused significant ion exchange throughout the entire sample. In the case of FA2, the central region of the sample appeared pink/purple meaning the pH remained above 9.0 in this region. This suggests the acid did not ingress or cause significant chemical alteration to the centre of FA2. The superior performance for FA2 was likely related to the reduced porosity of 16.9%, compared with 19.2% for FA1 (Table 3). The large pores observed in FA1 may also have allowed the acid to ingress rapidly (Fig. 3). This could prove an issue for the use of fly ash geopolymer concrete mixes to protect steel reinforcement from corrosion. The high pH of concrete is crucial for protecting steel reinforcement from corrosion as it provides a protective layer inhibiting the commencement of corrosion [76].

The performance of PC was vastly different. Almost the entire cross-section of the samples turned pink/purple following the application of phenolphthalein solution. Only the outside layer (< 2 mm) had a reduction in pH below 9.0. This suggests that the core of PC remained relatively unchanged by the acid. This may be related to the more dense microstructure found in PC (Sect. 3.1). It is worth noting that these results only provide an indication of the depth of acid penetration. However, they do help in understanding the nature of acid attack for each mix. PC suffered much larger mass losses (Fig. 5) and appeared more significantly damaged when samples were visually assessed (Fig. 6). However, the internal core of the samples remained largely unaffected. On the other hand, FA1 and FA2 exhibited smaller mass loss and a relatively undamaged outer surface but their internal core suffered from a reduction in pH suggesting greater acid ingress compared with PC.

3.5 Leaching behaviour

Figure 9 shows the pH of the acid solutions at the end of each exposure cycle during exposure of each mortar mix to 0.10, 0.31 and 0.52 mol/L solutions of acetic and lactic acids. The pH of each acid solution is also shown as a point of reference. At the end of each exposure cycle the pH of each acid solution has increased significantly due to the ion exchange between the sample and acid solutions. The pH increase is much higher for PC throughout which is likely to be due to the availability of calcium which is leached into the acid solution. For both fly ash geopolymer and Portland cement mixes the pH of the acid solutions used for storing the samples generally decreased with each exposure cycle suggesting fewer ions were available in the samples for exchange. This is likely to be due to depleted (buffer) layers remaining intact preventing heavy leaching to occur from internal layers. For each mix the pH of the acid solutions was greater for acetic acid compared with lactic acid, this is likely due to the increased initial pH of the acid solution (Fig. 9). For the PC mix it could also be due to the increased solubility of the calcium salt of acetic acid compared with that of the calcium salt of lactic acid [21], allowing additional OH anions to go into solution following dissolution of calcium rich phases. This shows the difference in performance of cementitious materials when exposed to different acid types and highlights the value in understanding the performance of materials when exposed to various types of acidic solutions.

Fig. 9
figure 9

pH of acid solutions at the end of each exposure cycle during exposure of FA1, FA2 and PC mortars to a 0.10, b 0.31 and c 0.52 mol/L of acetic and lactic acid solutions. pH of original acetic and lactic acid solutions shown by dashed lines

Figure 10 shows the cumulative concentration of (a) aluminium, (b) calcium, (c) sodium and (d) silicon in 0.52 mol/L acetic and lactic acid solutions during 21 days of paste samples immersion. The main leachate observed from FA1 and FA2 when exposed to both acid types was sodium. This is in agreement with Nguyen and Skvara [77] which found that sodium from fly ash geopolymers naturally diffused slowly into aqueous solutions. Smaller quantities of other elements were also observed including aluminium, calcium, silicon, potassium, magnesium and iron. Concentrations observed were relatively similar for both acid types. However, slightly more aluminium was observed due to lactic acid exposure when compared with acetic acid exposure. This is likely due to lower dissociation constant of lactic acid and the higher solubility of the aluminium salts of lactic acid compared with the aluminium salts of acetic acid [21]. Additionally, the complexation of cations and anions may influence these mechanisms. It has been reported that aluminium complexation by acetate may have an effect on the proportion of aluminium inserted into silica-rich gel formed after acid attack [21, 78, 79]. The increased aluminium found in solution would account for the larger strength losses for FA1 and FA2 due to lactic acid exposure (Fig. 7), and could be related to additional dealumination of N–A–S–H gel. The main leachate from PC was calcium, with slightly more leached due to acetic acid when compared with lactic acid. This is likely to be due to the high solubility of calcium acetate which is the calcium salt of acetic acid [78,79,80].

Fig. 10
figure 10

Cumulative concentration of a aluminium, b calcium, c sodium and d silicon in 0.52 mol/L acetic and lactic acid solutions following 21 days of FA1, FA2 and PC paste samples immersion

3.6 Microstructural changes

Figure 11 shows the XRD patterns of a) FA1, b) FA2 and c) PC pastes following 21 days of exposure to 0.52 mol/L acetic and lactic acid solutions. The fly ash geopolymer and Portland cement pastes which were not exposed to acid are also shown for comparison. The main crystalline phases present in unexposed FA1 and FA2 were quartz (SiO2), mullite (Al6Si2O13) and hematite (FeO2). Quartz was identified using PDF # 01-085-0504 and the main peaks were located at 20.8, 26.6, 50.2 and 60° 2θ. Mullite was identified using PDF # 01-083-1881 and the main peaks were located at 16.4, 26.0, 26.3, 33.2, 39.3, 40.9, 42.6, 60.7° 2θ. Hematite was identified using PDF # 01-073-0603 and the main peak was located at 35.6° 2θ. The broad hump in FA1 and FA2 between approximately 15 and 30° 2θ indicates the presence of amorphous silicate and aluminosilicate gel phases [75, 81], which in this case was most likely N–A–S–H gel. Following exposure to both acetic and lactic acids, the peaks due to quartz, mullite and hematite remained and appeared unaffected. The broad hump located between 15 and 30° 2θ was still present which suggests that some form of silicate or aluminosiliacte gel remained following acid exposure. The only change being that the broad hump appeared to shift to be centred at a lower angle. Centring of the peak in this region is typically observed for unreacted fly ash and may suggest that some of the reacted aluminosilicate phases have broken down leaving behind more unreacted fly ash particles [75, 81, 82].

Fig. 11
figure 11

XRD patterns of a FA1, b FA2 and c PC pastes stored for 21 days in water (unexposed) and 0.52 mol/L acetic and lactic acid solutions

The main crystalline phases identified in PC were calcium hydroxide and ettringite. Calcium hydroxide was identified using PDF # 01-075-0571 and the main peaks were located at 18.1, 34.1, 28.7, 47.1, 50.8, 54.4 and 62.6° 2θ. Ettringite was identified using PDF # 00-041-1451 and the main peaks were located at 9.1, 15.8, 18.9 and 22.9° 2θ. Following exposure to both acetic and lactic acids, substantial changes were observed. The peaks associated with calcium hydroxide and ettringite were no longer present indicating they have been removed due to acid attack. Instead calcium carbonate (calcite) was identified by PDF # 01-086-2334 and the main peaks were located at 23.1, 29.4, 36.0, 39.4, 43.2, 47.5, 48.5, 57.4 and 60.7° 2θ. Calcite was also identified by other authors [4, 20, 83] after Portland cement pastes were exposed to acid attack and may be linked to the precipitation of calcium and carbonate ions [10]. Calcium is available from the dissolution of phases with high calcium content such as calcium hydroxide, ettringite and C–S–H. Carbonate may be present from small amounts of carbon dioxide dissolved in solution [10]. In addition, calcium lactate hydrate was observed following exposure of PC to lactic acid. It was identified by PDF # 00-005-0101 and the main peaks were located at 7.5, 9.0, 15.0 22.1 and 27.4° 2θ. De Belie et al. [7] and Singh et al. [84] also reported the presence of a salt of calcium lactate due to the interaction between lactic acid and calcium hydroxide. This explains why less calcium was observed due to lactic acid exposure for PC (Fig. 10). The calcium salt of acetic acid was not stable enough to avoid dissolution allowing additional calcium to be observed in the acetic acid solution (Fig. 10).

Figure 12 shows the FTIR spectra of a) FA1, b) FA2 and c) PC paste samples following exposure to 0.52 mol/L acetic and lactic acid solutions. The fly ash geopolymer and Portland cement pastes which were not exposed to acid are also shown for comparison. For each sample the small band at approximately 1640 cm−1 was related to vibrations of OH and H–O–H groups indicting the presence of water molecules [85,86,87,88]. For mixes FA1 and FA2, the main peak which was observed at 997 and 991 cm−1, respectively, is assigned to the presence of asymmetrical T–O vibrations (T = Si or Al) indicating the presence of N–A–S–H gel [89]. Following acid attack this main peak shifted to higher wave numbers which indicates a higher Si/Al ratio and is attributed to dealumination of the binding gel [90]. The extent of the shift can also be related to the degree of damage caused by acid attack [83]. For FA1 the shift was from 991 to 1022 and 1051 cm−1 for acetic and lactic acid, respectively. For FA2 the shift was from 997 to 1018 and 1049 cm−1 for acetic and lactic acid, respectively. Therefore, the extent of the shift was similar for both FA1 and FA2 suggesting the additional activator dosage in FA2 had no impact on the resistance of reaction products to acid attack. It can also be noted that the shift was larger for lactic acid for both FA1 and FA2 suggesting lactic acid caused more dealumination. This is in agreement with the leaching behaviour which found increased concentrations of aluminium in the lactic acid solutions (Fig. 10a).

Fig. 12
figure 12

FTIR spectra of a FA1, b FA2 and c PC pastes stored for 21 days in water (unexposed) and 0.52 mol/L acetic and lactic acid solutions

For PC, the main peak was located at 960 cm−1 and shifted to 1018 and 1029 cm−1 for acetic and lactic acid, respectively. This is likely due to the decalcification of C–S–H gel [83], suggesting lactic acid caused further decalcification compared with acetic acid, which is in agreement with the mass losses observed (Fig. 5). PC had a small shoulder at 1105 cm−1 associated with the presence of ettringite [91]. Following acid exposure, this shoulder at 1105 cm−1 was no longer visible suggesting it has been removed due to acid attack. Additional peaks observed at approximately 875 and 1425 cm−1 were due to carbonate species and likely to indicate the presence of calcite [92,93,94]. At around 1580 cm−1, an additional peak was observed in the PC sample exposed to lactic acid. This peak has previously been related to carboxylic acid salts, in particular calcium lactate hydrate [95,96,97,98]. These observations are in agreement with findings from XRD analysis (Fig. 11c).

4 Conclusions

This paper investigated the potential of fly ash geopolymers to be used in certain applications where high resistance to organic acid is required. Compared with Portland cement mortar, fly ash geopolymer mortars appeared visibly less susceptible to organic acid attack, i.e. lower degree surface spalling and breakdown of paste was observed. These findings were confirmed by the mass losses, which were significantly larger for the Portland cement mortar. This was due to the enhanced resistance of the reaction products formed. The failure mechanism involved the dealumination of N–A–S–H gel leaving behind a highly siliceous product. On the other hand, the attack on the surface of Portland cement samples was more aggressive, mainly due to the availability of more phases which are susceptible to organic acid attack. Calcium hydroxide, C–S–H and ettringite were all found to be vulnerable to degradation, mainly due to ion exchange involving calcium. The formation of calcium salts was also a factor. In the case of acetic acid attack, calcium acetate was formed, which is highly soluble and resulted in a high level of calcium being drawn into solution. In the case of lactic acid attack, calcium lactate was formed due in part to the dissolution and decalcification of phases such as calcium hydroxide, C–S–H and ettringite. However, despite the reduced mass losses for fly ash geopolymers they have a considerable drawback. Their porosity was relatively higher compared with Portland cement mortars, making them susceptible to loss of alkalinity and ingress of acid, which could be detrimental if used in structures containing steel reinforcement. The percentage strength losses were similar for each mix investigated. Therefore, depending on the indicators considered and end use application, fly ash geopolymer binders may be considered to have better or worse resistance to organic acid than Portland cement binders.

Increasing the alkaline activator dosage had no influence on the resistance of the reaction products formed in fly ash geopolymers, hence similar mass losses were observed. However, a larger compressive strength was obtained and a less porous microstructure was formed, allowing a larger residual strength following acid attack. Additionally, the mix with higher activator dosages (FA2) was less susceptible to alkalinity loss and appeared to prevent to some degree the ingress of acid.

In applications where no structural reinforcement is necessary, fly ash geopolymers have the potential to improve service life due to the resistance of their reaction products. It may be worthwhile to consider fly ash geopolymers as a repair material for surfaces which are experiencing organic acid attack or as a layer of protective material for PC based systems. Although due to the high temperature curing required, attention should be given to develop further applications where some form of high temperature curing is possible, i.e. precast elements. Additionally, consideration should be given to improving the pore structure of fly ash geopolymers making them less susceptible to ingress of acidic solutions. If this can be achieved without affecting the susceptibility of their reaction products to organic acid attack, fly ash geopolymers have the potential to provide enhanced organic acid resistance compared with traditional Portland cement based materials.