Abstract
Objectives
To establish normative data of plethysmograph variability index (PVI), a simple non-invasive tool to measure fluid responsiveness, in neonates.
Methods
All healthy term and late preterm neonates were enrolled. PVI was recorded by pulse-oximeter on first three days of life along with other vital parameters. Data was analysed using SPSS software.
Results
The median PVI value was noted to be 21 with a wide range. The distribution of PVI did not differ according to day of life/ gestational age/ gender/ weight for gestational age. It did not significantly correlate with heart rate, gestational age or birth weight. A weak positive correlation was noted between PVI and PI (Rho = 0.157, p <0.001).
Conclusions
PVI normative data in neonates has been presented. Serial trend of PVI values is more useful than a single value in making clinical decisions.
Similar content being viewed by others
References
Ueyama H, Kiyonaka S. Predicting the need for fluid therapy—does fluid responsiveness work? J Intensive Care. 2017;5:34.
Cannesson M, Aboy M, Hofer CK, Rehman M. Pulse pressure variation: where are we today? J Clin Monit Comput. 2011;25:45–56.
Lee JH, Kim EH, Jang YE, Kim HS, Kim JT. Fluid responsiveness in the paediatric population. Korean J Anesthesiol. 2019;72:429–40.
Pişkin Ö, Öz İİ. Accuracy of pleth variability index compared with inferior vena cava diameter to predict fluid responsiveness in mechanically ventilated patients. Medicine. 2017;96:e8889.
Bedi PS, Pahwa B, Hooda B, Dwivedi D. Plethysmographic variability index as a tool to assess fluid responsiveness in critically ill patients: a correlation study with inferior vena cava distensibility index. Int J Res Med Sci. 2019;7:4663–72.
Yin JY, Ho KM. Use of plethysmographic variability index derived from the Masimo pulse oximeter to predict fluid or preload responsiveness: a systematic review and meta-analysis. Anaesthesia. 2012;67:777–83.
Renner J, Broch O, Gruenewald M, Scheewe J, Franckson H, Jung O. Non-invasive prediction of fluid responsiveness in infants using pleth variability index. Anaesthesia. 2011;66:582–9.
Byon HJ, Lim CW, Lee JH, et al. Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery. Br J Anaesth. 2013;110:586–91.
Bagci S, Muller N, Muller A, Hyedweiller A, Bartmann P, Franz AR. A pilot study of the pleth variability index as an indicator of volume responsive hypotension in newborn infants during surgery. J Anesth. 2013;27:192–8.
Latini G, Dipaola L, De Felice C. First day of life reference values for pleth variability index in spontaneously breathing term newborns. Neonatology. 2012;101:179–82.
Raja A, Balashankar S, Mathiarasan K. Perfusion index and plethysmographic variability index values in spontaneously breathing clinically stable term neonates in room air in the first 10 days of life. Pediatr Rev. 2017;4:531–6.
Author information
Authors and Affiliations
Contributions
VN collected the data, analysed the results and wrote the initial draft; KNN designed the study, analysed the results and revised the manuscript; VHA and RSS helped to design the study and revise the manuscript. KNN will act as guarantor for this manuscript.
Corresponding author
Ethics declarations
Conflict of Interest
None.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Narayanaswamy, V., Swamy, R.S., Harohalli A, V. et al. Plethysmograph Variability Index Values in Healthy Neonates – An Observational Pilot Study. Indian J Pediatr (2023). https://doi.org/10.1007/s12098-023-04897-y
Received:
Accepted:
Published: