Introduction

For high melting point metals containing reactive elements, the possibilities to measure surface tension are very limited. The most commonly used methods are the support-assisted or container-assisted ones, namely the sessile drop (SD) method and a variant of it, the large drop (LD) method (Ref 1) (Fig. 1a and b, respectively). However, the high melting temperature and the chemical reactivity, featured by the majority of metal systems for high-tech applications, increase the experimental difficulties of these ground-based techniques, thus lowering the measurements’ accuracy. The inaccuracy can be caused by numerous sources of errors such as those due to the determination of the liquid metal density and the presence of impurities coming from the container or from the environment. To overcome these problems, the proper selection of the container material is a critical stage, often performed after a preliminary study of its wetting and reactivity in contact with high melting point metals (Ref 2-4). Therefore, only a few methods are really suitable for accurate measurements of the thermophysical properties at high temperatures using non-contact techniques. One of them is certainly the containerless electromagnetic levitation-oscillating drop (EML-OD) method (Ref 5).

Fig. 1
figure 1

Schematic presentation of methods for surface tension measurements: (a) conventional SD method; (b) LD; (c, d) conventional PD using a capillary; (d) improved design of internal shape of a capillary to remove native oxide film from a metal liquid (Ref 19); (e) PD accompanied with melting of the metal rod end with ion beam

Recently, a new quasi-containerless procedure has been proposed to measure the surface tension of very high melting metallic systems (Ref 6, 7). The procedure combines in one test two methods: the pendant drop (PD) and the SD. The combined procedure allows the performance of both PD and SD measurements under the same conditions and in the same advanced experimental complex that has been designed for investigations of capillarity phenomena at very high temperature (up to 2400 K) (Ref 8). Using a contact heating procedure in the conventional SD method (Fig. 1a), the metallic sample and the substrate (support) are in contact when heated from room temperature to the experimental one as well as during testing at that temperature. In the PD method (Fig. 1c), a metal, placed in a refractory capillary (container), is fast heated to the required temperature and immediately squeezed through a hole in the capillary to form a liquid metal drop. In contrast to the SD techniques (i.e., the conventional one and its LD modification shown in Fig. 1a and b, respectively), during surface tension measurements, the PD contacts the capillary at its tip only (Fig. 1c, d).

The PD is a well-known classical method used for surface tension measurements since the early works by Bashforth and Adams (Ref 9) and Adreas et al. (Ref 10). Particularly, it is widely used in ambient temperature liquid state materials science for non-metallic systems such as water or organic liquids. However, following the review by Keene (Ref 11), only a few reports are available on the conventional (using a capillary) PD measurements of surface tension of metals and they are limited to low melting temperature metals such as mercury (234 K) (Ref 12), gallium (303 K) (Ref 13), and selenium (494 K) (Ref 14). At the same time, it is often accepted that the PD method is one of the most convenient, versatile, and accurate solutions to measure the surface tension of refractory metals (Ref 15). To do this, the surface tension is determined from the weight of the detached drops produced in the PD tests. This method is known as the drop weight (DW) method or more precisely as the PD/DW method. From Keene’s review (Ref 11), surface tension data are available for a large family of pure metals, including Cu, Co, Cr, Fe, Gd, Ge, Hf, Ir, Mo, Mn, Nb, Ni, Os, Pd, Pt, Pl, Re, Rh, Ro, Si, Ta, Ti, U, W, V, and Zr. For a few of them, characterized by extremely high melting temperature, it is the only method that makes possible the surface tension measurements, i.e., Hf (2500 K), Ir (2716 K), Nb (2740 K), Os (3300 K), Re (3453 K), Ru (2523 K), Ta (3287 K), U (1405 K), V (2175 K), W (3653 K), and Zr (2125 K). However, for refractory metals, the PD/DW procedure forming the PD differs substantially from the conventional PD method (Ref 16) because instead of a capillary tube with a liquid, it involves melting the end of a metal rod with an electron beam (Fig. 1e) to form a PD under the ultrahigh vacuum (UHV) conditions (Ref 17): The surface tension is determined from the weight of the detached drops. On the one hand, the PD/DW method enables reaching extremely high temperatures with an electron beam when molten metal is in contact only with its own solid (no contamination from a container). However, the PD/DW can be applied only at temperatures just near the melting point of the metal rod. Thus, it is not suitable for investigation of composition and/or temperature dependences of the surface tension of most metallic systems. It should be stressed that the PD/DW data on the surface tension at melting temperatures are available for a number of pure refractory metals as well as for a few pure metals of much lower melting points (Bi, Zn, Cd) (Ref 11), but there are no data for the conventional PD method, besides Hg, Ga, and Se.

For extremely high temperature applications, supplementary improvement of the PD method was proposed by Thiessen and Man (Ref 18). They applied a containerless melting of the end of a high purity metal rod (Zr) by bombardment with an electron beam to form a PD under UHV conditions together with the digitization of the PD profile, captured by a CCD, to compute the surface tension. However, similar to the PD/DW method, application of this improved PD procedure is limited to near melting temperature only and it is rather suitable for pure metals, but not for alloys, as suggested by Thiessen and Man (Ref 18).

The PD/SD combined method discussed in this study is providing further development of testing procedures for high temperature surface tension measurements. For the first time, this procedure was successfully applied for the determination of the surface tension of a class of reactive metal systems, the liquid γ-TiAl-based alloys, the high melting temperature of which is responsible for serious methodological problems, as reported in Ref 6. The idea of the proposed testing procedure was based on the assumption that, even for very reactive systems, there are certain conditions and a period of time when reactivity is negligible and, therefore, a significant improvement in accuracy and reliability of measurements can be obtained. In order to reach such conditions, both the area of contact and the time of contact between the metal and the container should be considerably decreased. Such conditions can be achieved by applying a capillary (a very small area of contact of the drop with the container at the tip of a capillary only), together with fast manipulating of liquid metal (drop squeezing, movement, and deposition) at high temperature under vacuum or protective atmosphere, accompanied by fast recording of the drop images with a high-speed CCD camera.

Additional improvement in testing conditions can be attained by suppression of the interaction between the melt and the capillary. For example, even a very thin, nanoscale-sized native oxide film on a metal sample that usually creates many problems in the investigation of capillary properties at high temperature (Ref 19), in this particular case, may be very helpful as a natural barrier to chemical reactions between the metal and the internal wall of the container. This approach was successfully applied in Ref 6 for surface tension measurements of highly reactive TiAlNb and TiAlTa alloys, taking advantage of the fact that the surface of these samples is covered with a native alumina layer which slows down chemical reaction of the alloy with the alumina capillary used. Additionally, in order to produce oxide-free droplets, necessary for reliable measurements of surface tension, the metal drop was in situ cleaned directly in the vacuum chamber (Ref 20) by squeezing the metal through the alumina capillary of a special design, allowing mechanical removal of an oxide film at the sharp internal edges of the capillary (Ref 19) (Fig. 1d).

Despite the fact that in the proposed procedure the contact of the liquid metal with a capillary is unavoidable, the time of the drop/capillary contact at the capillary tip can be limited to a few seconds needed for drop stabilization. As demonstrated in our previous work (Ref 6) using a high-resolution and high-speed camera (up to 2000 frames/s), a large number of high quality drop images, indispensable for reliable surface tension calculations, are recorded.

Seeking a practical embodiment of the above ideas, an advanced experimental complex has been designed which enables studying the capillary phenomena in liquid metals at high temperature and under high vacuum or protective atmosphere using different testing methods and procedures, as described in detail in Ref 19 and 20.

In this work, attention has been focused particularly on methodological aspects of the proposed combined PD/SD method due to the novelty of its application to very high temperature metallic systems. In fact, on the basis of promising results obtained for the liquid γ-TiAl-based alloys (Ref 6), the verification of certain aspects of the new methodology for its optimization seemed to be necessary. For this reason, it was decided to measure the surface tension of a few pure metals taken as reference materials due to availability of extensive experimental results reported in the literature.

Measurements of surface tension of pure Cu, Ni, Al, and Fe obtained using the same experimental facility and by the combined PD/SD testing procedure are presented. To confirm the validity of the new quasi-containerless method, the results are discussed in the framework of the available literature data obtained by different methods, particularly by the containerless ones such as the EML-OD method.

Thus, the revision of literature data as well as new reference data for the metals selected is beyond the scope of this work.

Materials and Methods

Experimental complex, described in detail in Ref 8, equipped with several manipulators, allowing application of different testing procedures as reported in Ref 6, 7, 19, and 20, was used in this study. Special mention must be made of the fact that the design of the experimental complex, built from a few independent and directly interconnected vacuum chambers, allows loading and removing of the metal samples, the substrates, and the capillaries without the necessity to open the working (high temperature) vacuum chamber.

Surface tension measurements have been performed in a resistance furnace with a Ta heating element surrounded with Ta and Mo isolation screens. All elements of manipulators as well as the experimental table (as a support for a substrate, Fig. 1a, b), introduced inside the Ta heater during the tests, were also made from Ta. The capillary (container), with a hole diameter of 1.1 mm, was produced from alumina powder of 99.995% purity without any sintering aids.

High purity (99.999%) Cu, Ni, Al, and Fe metals were used to prepare the samples. Directly before loading into the vacuum chamber of the furnace, the metal samples of desired volume (about 0.5 cm3) were mechanically cleaned by scratching and then chemically rinsed with pure ethanol in an ultrasonic bath. Next, the selected sample was placed in the Al2O3 polycrystalline capillary and introduced into a vacuum chamber. After melting and reaching the required temperature, the metal was squeezed through the capillary to produce a PD. The surface tension was measured as a function of temperature in steps of 50 K. For each temperature step, the drop’s images were recorded for about 10 min by a high-speed digital camera, equipped with high quality photographic lens allowing a high resolution at optical wavelength. Since the main sources of error are the intrinsic TV-camera distortion, the discretization process, and the evaluation of the system magnification factor, all the optical devices were mounted on an optical bench. The digital images were analyzed to obtain numerical data points of the contour of the drop. Dedicated software packages have been developed (Ref 21) capable of obtaining surface tension data in real time together with other experimental parameters (i.e., drop shape and size, surface area, contact angle). In order to get better repeatability of the measurements, the focusing, the focal length, and the diaphragm of the optical system were kept fixed. Considering that the knowledge of the magnification factor is essential for deriving the real drop profile coordinates from the acquired ones, the magnification factor was calculated individually for each image. The surface tension was calculated using an improved version of the Maze and Burnet algorithm (Ref 22).

In this study, the measurements by the PD method were carried out in a few steps. First, the apparatus was heated up to the measurement temperature keeping the capillary in the low temperature zone of the UHV chamber. Next, using a special manipulator, the capillary was introduced into the high temperature zone, where liquid metal was squeezed through the capillary to form a drop with appropriate dimensions allowing the correct profile acquisition.

A similar procedure was applied when the liquid metal was dispensed by the capillary on a flat substrate, forming a SD (Fig. 1a), or into a crucible (Fig. 1b) for the measurements by the LD method (Ref 1-3). In particular, in this study, sapphire plates and crucibles cut from a (0001) single-crystal α-Al2O3 rod, pretreated for 2 h at 1300 K in vacuum, have been used.

It should be underlined that at very high temperatures, manipulating a capillary located inside an UHV chamber using outside control may create several technical problems. Particularly tricky is placing the capillary in perfect vertical position and obtaining drops of suitable dimensions that will remain fixed at the capillary orifice. Moreover, the control of the size and stability of a drop formed at a capillary tip is particularly difficult because it depends not only on the metal properties (density, surface tension, viscosity) but also on the size of the capillary hole.

However, the capillary size does not influence the surface tension values (Ref 23). The size of the capillary used in this work (i.e., 1.1 mm diameter hole) was satisfactory in obtaining stable drops of Al, Ni, and Fe, but it was not sufficient to get Cu drops of appropriate dimensions due to an unfavorable ratio between surface tension and density.

Furthermore, the high temperature emissivity is another factor affecting the drop image quality, thus making the measurements difficult. Therefore, IR cut-off filters were used for this purpose.

For the measurements by both PD and SD (or LD) performed in this work, the final values of the surface tension were calculated as an average of all the data measured at each temperature. The calculated experimental error of the surface tension measurements was less than 1%.

Results and Discussion

A large number of experimental data are available in the literature for pure Cu, Ni, Al, and Fe that have been chosen as reference materials to check the applicability of the new procedure for high temperature measurements of metallic systems (Ref 11, 24-51). The surface tension values obtained in this work were preferably compared with the most recent data, in particular with those reported in the recent review of Mills and Su (Ref 24). Special attention has been paid to the comparison with the literature data obtained by the containerless EML-OD method.

Copper

The first attempt to form a PD was done with Cu. Measurements were carried out under an atmosphere of flowing high purity N5.2 argon (99.9992%) from Air Products Co (P tot = 8.5 × 104 Pa). The presence of a Ta heater, acting as an oxygen getter, assured an oxygen partial pressure inside the test chamber equal to \( P_{{{\text{O}}_{ 2} }} \) = 10−8 Pa at the testing temperature T = 1500 K.

However, only at T = 1500 K, a metal drop stable in dimensions was formed allowing a reliable acquisition of its profile coordinates. The resulting value of surface tension is shown in Fig. 2.

Fig. 2
figure 2

Surface tension of liquid Cu measured by PD method in this work (○). For comparison, the literature data on the surface tension of Cu obtained by other techniques are also plotted: 1—“suggested” data (Ref 11); 2—LD method (Ref 32); 3-4—EML-OD method (Ref 33) and “mean values” as reported in Ref 11; 5—“adopted data” (Ref 24); 6—SD method (Ref 36); 7—SD (Ref 35); 8—EML-OD (Ref 37); (∇) PD/DW method (Ref 34)

At higher temperatures, several technical problems, mainly related to the high temperature of the experiment and initially non-optimized setup of the PD system, occurred during the experiment on liquid Cu. Due to these problems, it was difficult to get Cu drops of appropriate dimensions and to keep them pendant for the time necessary to complete the acquisition procedure. Indeed, due to an unfavorable ratio between surface tension and density, increasing the drop size made the Cu-PD fall down after only a few seconds before reaching the appropriate dimensions. These difficulties made impossible also the measurements by the LD method due to the inability to dispense sufficient amount of material into the crucible, since at that time the size of both the capillary and the crucible was not optimized, but this task is beyond the scope of the present research work.

Nevertheless, the value obtained at T = 1500 K agrees well with the corresponding linear fit of the surface tension values of Cu measured by the LD method in the temperature range of 1423-1523 K (Ref 32). These last values are included among the suggested values of Keene’s review (Ref 11) and those defined as “adopted” in the recent review of Mills and Su (Ref 24). Furthermore, our data are also in conformity with the recent results obtained with the containerless EML-OD method (Ref 33). In particular, it should be noted that the latter overlaps the linear fit of the mean values of Cu surface tension as reported in Ref 11. In Fig. 2, the surface tension value of Cu, measured at the melting point by the PD/DW method (Ref 34), is also shown for comparison.

Nickel

In the case of liquid nickel, the measurements were performed at T = 1773 K under vacuum (P tot ≤ 10−4 Pa) with a corresponding value of oxygen partial pressure \( P_{{{\text{O}}_{ 2} }} \) < 10−7 Pa (and \( P_{{{\text{H}}_{ 2} {\text{O}}}} \) < 10−6-10−5 Pa), estimated by mass spectrometry using real time measurements by means of a quadrupole residual gas analyzer (Ref 8, 20). Contrary to Cu, the experiments on Ni have faced fewer difficulties in forming stable PD. However, the very high emissivity both of the furnace elements and the Ni sample above its melting point (1726 K) caused new problems in getting sharp drop images. In this case, application of a special filter was helpful for the extremely difficult setting up of the optical line.

Figure 3 shows the surface tension values of Ni measured in the temperature range of 1773-1923 K in comparison with the literature data obtained using different techniques (Ref 24, 38, 39). The linear fitting of surface tension values of pure Ni obtained in this work is in agreement with the literature data. The surface tension temperature coefficient is very close to that of the linear relationships suggested by Keene (Ref 11) and defined as “adopted” by Mills and Su in Ref 24. In particular, a good agreement was found with the results obtained by the containerless EML-OD method reported by Brillo and Egry in Ref 38, even if the absolute values obtained here by PD measurements are higher.

Fig. 3
figure 3

Surface tension of liquid Ni measured by PD method in this work (●). For comparison, the literature data on the surface tension of Ni obtained by other techniques are also plotted: 1—linear fit of the PD data; 2—SD method (Ref 35); 3—“adopted data” (Ref 24) and “mean values” (Ref 11); 4—EML-OD method (Ref 38); (▲) PD/DW method (Ref 39)

As in the case of Cu, a value of the Ni surface tension measured by the PD/DW method was found in the literature (Ref 39). For comparison, this value is shown in Fig. 3.

Aluminum

The favorable combination of the ratio between surface tension and density of liquid Al, together with a capillary suitably sized, allowed getting stable drops with appropriate dimensions. Thus, reliable data on the aluminum surface tension were obtained by application of the combined PD/LD method, taking measurements in the temperature range of 973-1273 K under a vacuum. The measurements were performed under a total pressure of P tot = 10−4 Pa with a corresponding value of oxygen partial pressure \( P_{{{\text{O}}_{ 2} }} \) = 1.3 × 10−7 Pa (\( P_{{{\text{H}}_{ 2} {\text{O}}}} \) = 10−6-10−5 Pa), estimated by the mass spectrometry during Al surface tension measurements. Figure 4 shows the surface tension values of Al measured in this work, simultaneously by PD and LD (in a sapphire crucible). Each value represents the average of a large number of measurements performed under isothermal conditions, maintained for at least 10 min, so as to meet the equilibrium conditions. In spite of the experimental difficulties caused by the high temperature and the IR emission, the obtained results for Al can be considered as successful for the purpose of this study. The values were compared with the literature data obtained by other techniques (Ref 24, 47-52).

Fig. 4
figure 4

Surface tension of liquid Al measured in this work by the combined method: PD method (○) and LD method (■). For comparison, the literature data on the surface tension of Al obtained by other techniques are also plotted: 1—oxygen-free values suggested by Ref 24; 2—LD/AD method (Ref 51); 3—linear fit of PD data obtained in this work; 4—linear fit of LD data obtained in this work; 5—LD (Ref 50); 6—EML-OD method (Ref 42); 7—oxygen saturated values suggested in Ref 24; 8—literature “mean values” (Ref 11); (∇) the highest value from Ref 49

The surface tension data obtained by PD and LD are in good agreement with most of the literature data, in particular with those obtained by containerless methods (Ref 42). The values achieved by PD are the highest and show the temperature coefficient to be in good agreement with the literature data.

For comparison, two other relationships are shown in Fig. 4 (marked with 1 and 2). Relationship 1 corresponds to the average of the few highest values reported in the literature and assumed as the oxygen-free values (Ref 24). The second one is the “low temperature” extrapolation of the values reported by Sarou-Kanian et al. (Ref 51), who measured the surface tension of Al in a temperature range of 1700-2100 K using the levitated drop/aerodynamic levitation (LD/AL) method. The highest value of the Al surface tension measured by Goumiri and Joud (Ref 49) is also shown.

Iron

Considering the favorable density/surface tension ratio, the combined procedure PD/SD was also used to measure the surface tension of liquid iron at T = 1973 K. In order to suppress liquid metal evaporation at high temperature, surface tension measurements were performed under static inert atmosphere P tot = 105 Pa of N5.2 argon (99.9992%) from Air Products Co. As a first step, a SD was produced by squeezing the liquid metal through polycrystalline alumina capillary onto a single-crystal α-Al2O3 (0001) plate. The next drop squeezed was kept pendant and both droplets were maintained at a constant temperature of 1973 K (Fig. 5) for 10 minutes to measure surface tension.

Fig. 5
figure 5

Image of an Fe-PD in the presence of a SD formed in the experimental complex apparatus at T = 1973 K

It should be highlighted that the contact angle value θ = 108° was assumed by the freshly deposited SD of liquid iron on the sapphire plate. Interaction phenomena occurring at the Fe/Al2O3 interface are well known (Ref 53): The reaction between the substrate and the droplet is the driving energy at the triple line, thereby affecting the surface tension reliability.

On the contrary, taking advantage of the lack of contact between the metal and the internal wall of the capillary, the surface tension data obtained by processing the droplet profiles of liquid iron in the pendant shape can be suitably compared with the literature. In particular, the surface tension value measured at T = 1973 K (Fig. 6) is very consistent both with the suggested values of Keene’s review (Ref 11) and those recommended in the recent review of Mills and Su (Ref 24). Moreover, the surface tension value of liquid iron obtained by the PD method in this study is in reasonable agreement with the one measured by Brillo and Egry (Ref 38) using the EML-OD method.

Fig. 6
figure 6

Surface tension of liquid Fe measured in this work by PD method (○). For comparison, the literature data on the surface tension of Fe obtained by other techniques are also plotted: 1—EML-OD method (Ref 38); 2—recommended data (Ref 24); 3—adopted data (Ref 11)

The results obtained in the present study and the most recent and representative literature data are summarized in Table 1. The experimental conditions and the methods applied for the measurements of surface tension (γ) are collected together with the experimental values and, when available, the surface tension-temperature dependence (linear fitting) is also given.

Table 1 Surface tension of the selected liquid metals measured in this work (indicated by *). For comparison, the literature data on the surface tension obtained by containerless EML-OD method are also reported

Summary

In order to test the applicability of a new procedure aimed to measure the surface tension of very high melting, high reactive metal systems, the surface tension of pure Cu, Ni, Al, and Fe was measured. The proposed combined procedure consists of using two techniques (the PD and the SD/LD) in one test in the same advanced experimental complex that has been designed for investigations of high temperature capillarity phenomena.

The analysis of the results obtained highlights a good agreement of the surface tension measurements, in particular with those obtained by the containerless EML-OD method. The difference in results is less than 1.5%, except for Ni, for which PD values are by about 5% higher. Following the aim of this work, it may be concluded that the results obtained confirm the feasibility of the new testing procedure recently proposed by the authors and for the first time applied for surface tension measurements of TiAlTa and TiAlNb alloys. This procedure, named the PD/SD combined method, shows several advantages and some drawbacks. The advantages are mainly due to the way of forming the liquid metal drop, because due to the formation of a PD by squeezing the liquid metal from a capillary and subsequent fast deposition of the drop on a substrate (SD), there are the following benefits:

  • the droplet squeezed through a capillary is free of primary native oxide film, affecting the reliability of surface tension measurements; this film is difficult to remove by any other way, particularly for oxidizable alloys;

  • the same oxide film plays the role of a barrier that might reduce or even prevent the interaction of the metal with the capillary during heating;

  • the contact of freshly squeezed liquid metal with either the capillary or a substrate is very short (a few seconds), compared to the conventional SD procedure;

  • similar to the LD method, the dispensed droplet deposited on a substrate has a high symmetry, thus improving reliability of surface tension measurements by the conventional SD procedure;

  • the PD procedure can be combined with the LD method by squeezing several small droplets into a crucible in order to get the total liquid volume required for LD measurements.

The comparison between the surface tension values of the few pure metals investigated in this work and the corresponding literature data is encouraging due to the satisfactory agreement. In addition, considering the good results previously obtained for the γ-TiAl-based alloys, a very high temperature and highly reactive technologically relevant class of structural materials, further applications of this experimental approach to study high melting point metal systems can be envisaged.

Nevertheless, in view of the application of this new experimental approach to study metal systems that are both highly reactive and oxidizable, further developments in the setup of the PD apparatus used in the proposed procedure are required. In this way, it is expected to get additional improvements in the accuracy and reliability of surface tension measurements. In fact, the performance of the experiments carried out in this work showed some drawbacks:

  • The use of alumina as a material for the capillary, due to the complexity of the design of its inner part and the manufacturing techniques currently available, is limitative. Therefore, in order to obtain better performances and accuracy of high temperature measurements, there is a justified need to have the possibility of different refractory materials available, depending on the metal system to be measured and limiting the mutual reactivity between the metal and the container (support).

  • Controlling the size of the PD is critical. The only way to obtain a real reproducibility of the measurements is by preventing the drops from falling during the experiments and by insuring a sufficient and stable drop volume to enable the drop profile acquisition to be effective. This problem is complex because it depends not just on physical variables and their temperature dependence but is also linked to technical factors such as the dimensions of the capillary. From this point of view, both the capillary internal volume and its hole size should be optimized individually for each metal system. Although some tricks have been adopted (such as the special design of the interior of the capillary, the controlled atmosphere, the presence of a getter), the quantitative determination of the oxygen present in the test chamber, particularly under flowing gas conditions, would allow an assessment of the actual oxidation conditions of the test system.

To overcome these drawbacks, needed for further development of testing methods and procedures for high temperature surface tension measurements, the additional improvements in the design of the experimental devices involve the following:

  1. (i)

    the use of new advanced refractory materials with both high chemical and high dimensional stability suitable for ultrahigh temperature measurements of liquid metallic systems;

  2. (ii)

    the development of new testing procedures allowing a better control of PD size;

  3. (iii)

    the control and real time monitoring of the oxygen content in the vicinity of the testing sample (drop).