Background

Malaria is a highly prevalent disease in tropical and subtropical regions, and nearly half of the world’s population is at risk of contracting it [1]. The rapidly shrinking malaria map takes us a step closer to worldwide malaria eradication. Yet, great challenges remain. To achieve elimination and prevent resurgence, surveillance systems must adapt to the changing malaria epidemiology and be able to detect all possible malaria infections in a timely manner. Thus, the accurate identification of all malaria infections, including symptomatic and asymptomatic, has become a vital component of the control and elimination programmes [2]. Asymptomatic malaria infection refers to malarial parasitaemia of any density in the absence of fever or other acute symptoms in individuals who have not received recent antimalarial treatments [3]. Some asymptomatic infections have parasitaemia levels that are detectable by microscopy, whereas others can only be detected by molecular methods and are termed submicroscopic infections. At any given time, the vast majority of individuals with detectable malaria parasitaemia can be categorized as asymptomatic [4], and they are regarded as important reservoirs sustaining malaria transmission [5]. Therefore, low-cost, highly sensitive and specific screening tools would be very useful in the malaria elimination phase [6].

Light microscopy (LM) is the cost-effective, gold standard for detecting symptomatic infections, but it has limitations for the diagnosis of malaria in asymptomatic individuals, especially in low-endemic settings [613]. It has been reported that both microscopy and rapid diagnostic tests miss infections when parasite densities are low (<10 parasites/µL) [14]. PCR is the most frequently used molecular method for detecting malaria. Several different target genes have been used, including the 18S ribosomal RNA gene (18S rRNA) [1519], tRNA [20], AMA1 [21], and cytochrome b [22, 23], among which the 18S rRNA gene is the most commonly used [11, 2426]. PCR-based methods include nested PCR with DNA (nD-PCR) [12, 24, 2731], nested reverse transcriptase PCR (nRT-PCR) [26, 30], quantitative RT-PCR [27, 3235], and more recently, capture and ligation probe-PCR (CLIP-PCR) [36]. PCR can typically detect 5–10 parasites/µL, while nRT-PCR can detect as few as 22 parasites/mL [26]. In addition, CLIP-PCR has been advocated for use in molecular epidemiological studies because of its higher throughput since samples can be pooled for analysis. It is necessary to compare the benefits of different methods, particularly for asymptomatic malaria.

Whereas most epidemiological surveillance has focused on the evaluation of parasite prevalence in representative populations, gametocyte carriage rarely has been assessed simultaneously. In this study, the prevalence of malaria infections was evaluated in 1005 healthy individuals in villages along the international border between China and Myanmar, where malaria elimination action plans are in place. The sensitivity and specificity of LM and three molecular diagnostic methods for detecting asymptomatic Plasmodium infections were compared. In addition, the relationship between parasite species detection using the Pv18s rRNA and gametocyte detection using the Pvs25 gene within individual samples was analysed.

Methods

Study area and sample collection

The study site is located in the northeastern Kachin State of Myanmar, along the China-Myanmar border (97.56°E and 24.75°N) [37]. One thousand and five healthy individuals (344 males and 661 females, ages 1–82 years) living in seven villages near the Laiza township were recruited in May (530), July (235) and November (240) of 2015. Finger-prick blood samples (~100 µL) were collected on Whatman 3 M filter paper, air-dried, individually sealed in plastic bags, and stored at −20 °C until use. In addition, 100 µL of finger-prick blood were collected in EDTA tubes, kept on ice, and transferred to a nearby field laboratory on the same day for processing. The study protocol was approved by institutional review boards of the Pennsylvania State University and the local Bureau of Health in Kachin. All participants or legal guardians gave written informed consent before entering the study.

Malaria diagnosis by LM

Thick and thin blood films stained with Giemsa were prepared and read according to the World Health Organization standard operating procedure in basic malaria microscopy with an oil immersion lens (100×) by two microscopists who had at least five years of experience. Each slide was examined for at least 100 good fields by each microscopist. For positive slides, parasite density was quantified in 500 white blood cells (WBCs) on thick blood films assuming that 1 µL of blood contains 8000 WBCs [38]. Thin films in the positive slides were further examined to identify the parasite species. For samples with discrepant results by the two microscopists, a third senior microscopist provided additional evaluation to reconcile the divergence.

Nucleic acid extraction and cDNA synthesis

Total RNA and genomic DNA were extracted from peripheral blood samples with Trizol (Invitrogen, Carlsbad, CA, USA) according to the manufacturer’s instructions. Briefly, 0.1 mL of blood sample in a 1.5 mL tube was mixed with 1 mL of Trizol and incubated at room temperature for 5 min. Two hundred µL of chloroform was added and mixed vigorously by hand for 15 s. Phase separation was done by centrifugation at 12,000×g for 15 min at 4 °C. The aqueous phase was transferred to a fresh 1.5 mL tube, where 10 µg of the carrier GlycoBlue Coprecipitant (Invitrogen) and 0.5 mL of 100% isopropanol were added to precipitate total RNA. The RNA pellet was washed with 1 mL of 75% ethanol twice, air-dried, dissolved in 30 µL RNase-free water, and stored at −70 °C. Genomic DNA was isolated from the interphase and phenol phase following the protocol for DNA isolation. Genomic DNA was dissolved in 30 µL of 8 mM HEPES buffer at pH 7.0–8.0 and stored at −20 °C. One microgram of each total RNA sample was directly used as the template for nested-PCR with primers for the Plasmodium 18S rRNA gene to verify that isolated total RNA had no genomic DNA contamination.

cDNA was synthesized from 1 µg of each RNA sample (~1/6 to 1/4 of total RNA) using the Takara RNA PCR kit (AMV) version 3.0 (Takara, Japan) in a total volume of 20 µL consisting of 1 µg RNA, 4 µL 5× reverse transcriptase buffer, 2 µL dNTP mix (10 mM each),1 µL primer of Random 9mer mixed with oligo dT-adaptor primer, 20 U (0.5 µL) RNase inhibitor, 10 U (2 µL) AMV reverse transcriptase, and RNase-free water to 20 µL.

PCR detection targeting the 18S rRNA

Nested PCR with genomic DNA (nD-PCR) or cDNA (nRT-PCR)

Modified nested PCR (nD-PCR) was performed as previously described based on the 18S rRNA gene [12, 15, 31, 3941]. Plasmodium genus- and species-specific primers for P. falciparum, P. vivax, Plasmodium malariae, and Plasmodium ovale, and expected sizes of PCR fragments and PCR reaction conditions are shown in Additional file 1. Primary PCR reactions were performed in 25 µL containing 14 µL distilled H2O, 1.0 µL each of rPLU5 and rPLU1 primers (10 µmol/L), 2.5 µL 10 × buffer, 2 µL dNTP mixture (2.5 mM), 0.5 µL rTaq (2.5 U), and 4 µL of genomic DNA. Nested PCR was performed used 2 µL of the primary PCR product as a template and species-specific primers for the four human malaria species in separate reaction tubes. PCR products were separated in 1.2% agarose gels. For PCR assessment, one positive control (from a symptomatic P. vivax case) and one negative control (sterile water) were used in a blind test for analysis. nRT-PCR was performed similarly as for nD-PCR using 1 µL cDNA template in the primary PCR. Three clinical P. vivax samples with an average density of 3000, 3800 and 4400 parasites/µL blood, respectively, were used to define the limits of detection (LOD) for nD-PCR and nRT-PCR. The average parasite density of each sample was determined by two microscopists, who counted parasites per 500 WBCs in thick smears assuming 8000 WBCs/µL blood. All three samples were first diluted to the same parasite density using the same whole blood from a healthy person, and then subjected to fourfold serial dilutions (2000–0.488 parasites/µL) and threefold serial dilutions (5.6–0.0026 parasites/µL) for nD-PCR and nRT-PCR, respectively. For each dilution and nucleic acid extraction, nD-PCR or nRT-PCR was performed in triplicates, and the lowest parasite density at which all three PCR replicates were positive was considered the LOD.

Capture and ligation probe-PCR (CLIP-PCR)

For CLIP-PCR, a 3-mm circle of dried blood spot on 3 M Whatman filter paper was punched out and lysed with 100 µL lysis mixture (Diacurate, Paris, France), 191 µL water, 3 µL mixed capture and detection probe for the Plasmodium genus, and 6 µL proteinase K (50 g/L) at 56 °C for 30 min with vigorous shaking. Pooled sample spots were lysed in the same manner. Lysates were then transferred at 100 µL per well to a 96-well capture plate (Diacurate). After incubation at 55 °C for 3 h, each well was washed three times with 150 µL wash buffer and incubated with 50 µL ligation mix at 37 °C for 30 min. The plate was then washed again and used for qPCR with 25 µL/well of PCR mixture containing 1× SYBR® Premix Ex (Takara) and 100 nmol/L primers. Amplification and detection were performed on an ABI 7500 apparatus (Applied Biosystems, Foster City, CA, USA) under the following conditions: 30 s at 95 °C, 45 cycles of 5 s at 95 °C, and 20 s at 60 °C. The melting curve was prepared from 65 °C to 90 °C using a default setting. The standard curve was made by threefold serial dilutions (8–0.004 parasites/µL) of a lysate of cultured P. falciparum 3D7 strain diluted with a parasite-negative whole blood lysate. For CLIP-PCR, the sample was considered positive if the fluorescent signal increased within 29 cycles and the melting curve was the same as that of the positive control [36].

RT-PCR detection targeting the Pvs25 gene

Two RT-PCR methods were used to detect P. vivax gametocytes in samples. For detection of P. vivax gametocytes in all 1005 samples, the 645 bp full-length Pvs25 gene was amplified using Pvs25-specific primers under specified reaction conditions (Additional file 1: Table S1) [42]. The PCR reaction contained 2 µL of 10× KOD-Plus-Neo buffer, 2 µL of 2 mM dNTPs, 0.8 µL of 25 mM MgSO4, 0.5 µL of 10 µM of pvs25_fw and pvs25_rev primers, 0.5 U of KOD Plus-Neo DNA polymerase (Toyobo, Osaka, Japan), and 1.0 µL cDNA in a final volume of 20 µL. PCR products were separated on 1.2% agarose gels. Three P. vivax gametocyte-positive samples with average gametocyte densities of 240, 208, and 320 gametocytes/µL blood, respectively, were used to define the LOD of the Pvs25 RT-PCR. Similarly, threefold serial dilutions of the three P. vivax gametocyte-positive samples (all diluted to 5.6–0.0026 gametocytes/µL) were used for RT-PCR, and the lowest gametocyte density at which all three PCR replicates were positive was considered the LOD.

The subset of samples that were positive for P. vivax parasites was further analysed by the TaqMan probe-based quantitative RT-PCR (qRT-PCR) targeting the Pvs25 transcript [43]. Sequences of primers as well as the FAM-BHQ1-labeled probes for Pvs25 (GenBank Accession No. XM_001608410), expected size of the PCR fragment and PCR conditions are shown in Additional file 1. The PCR reaction consisted of 10 µL of 10× primer Extaq buffer, 0.2 µL of 50× Rox Reference Dye II, 0.8 µL of pvs25_probe, 0.4 µL of 10 µM of pvs25_fw and pvs25_rev primers, 1.0 µL cDNA, and sterile water to 20 µL (Takara). A 115 bp fragment of Pvs25 was amplified with primers pvs25_fw and pvs25_rev from the cDNA of a symptomatic P. vivax gametocyte-positive case, cloned into the pMD-18T vector (Takara), sequenced, and used as the positive control plasmid. Tenfold dilutions of plasmid DNA (3 × 109 to 3 × 10−1 copies/µL) were made in triplicates to calculate a standard curve. The amplification efficiency (E) was calculated using the slopes of the standard curves (E = 10(−1/Slope) − 1). The LOD was measured using the threefold serial dilutions of the same three P. vivax gametocyte-positive samples (all diluted to 9–0.001 gametocytes/µL). qRT-PCR was carried out on an ABI 7500 apparatus (Applied Biosystems, Foster City, CA, USA) and analysed with 7500 Fast Software v2.3. To identify gametocyte-positive samples, the Ct values of standard curves obtained from assay-specific plasmids were routinely included in each 96-well plate.

Statistical analysis

Pair-wise comparison among the proportions of positive detections for the different methods was made by the McNemar’s exact test. Sensitivity and specificity were calculated from the numbers of true/false positives and negatives when each of the methods was considered to be the reference method by statistical analysis software SPSS and data combined using Microsoft Excel 2010 for Windows.

Results

Prevalence of Plasmodium infections detected by different methods

LM and three molecular detection methods targeting the asexual parasite 18S rRNA genes were compared side by side using 1005 blood samples collected from healthy residents in villages of a malaria-endemic area from northeastern Myanmar. LM only detected a total of 12 (1.19%) P. vivax infections. Both nD-PCR and nRT-PCR methods detected Plasmodium infections based on the expected sizes of the PCR fragments on agarose gels, while CLIP-PCR was based on the melting curves of the positive controls (Additional file 2). The method based on CLIP-PCR detected only a few additional infections compared to LM (19 infections, 1.89%) (Table 1). In comparison, nD-PCR detected 24 (2.39%) malaria infections, including 23 P. vivax and 1 mixed P. falciparum/P. vivax infections (Table 1). The RNA-based detection method nRT-PCR was the most sensitive, and detected 187 (18.61%) malaria infections, including 176 P. vivax, 5 P. falciparum, and 6 mixed P. falciparum/P. vivax infections (Table 1). No P. malariae or P. ovale infections were observed by any of the methods. Statistical analysis showed that all pair-wise comparisons of the detection rates of the four methods were significantly different (p < 0.05) (Table 1). Of the total 182 P. vivax and P. falciparum/P. vivax positive samples by nRT-PCR, 32 samples were P. vivax-positive by at least one of the other detection methods (LM, CLIP-PCR, or nD-PCR) (Fig. 1).

Table 1 Performance of different detection methods on asymptomatic malaria infections
Fig. 1
figure 1

Venn diagram showing the overlap in the number (percent) of individuals with asymptomatic Plasmodium infections in a population of 1005 as detected by light microscopy (LM) and one of the three molecular methods targeting parasite 18S rRNA genes (nD-PCR nested PCR using genomic DNA, nRT-PCR nested RT-PCR using parasite total RNA, CLIP-PCR capture and ligation probe-PCR)

Sensitivity and specificity of different methods of Plasmodium detection

Comparisons of sensitivity and specificity of the malaria detection methods are presented in Table 2. LM traditionally has been considered the ‘gold standard’, but its low sensitivity would lead to biased estimates for ‘false positives’ if it is used as the only reference method. Thus, comparisons were made with each method being considered as the reference. When the least sensitive LM method served as the reference, nD-PCR and nRT-PCR both showed high sensitivity (>90%), whereas CLIP-PCR only had ~50% sensitivity. When the commonly used nD-PCR was used as the reference, CLIP-PCR again showed modest sensitivity of ~50%, similar to that of LM. Compared to the most sensitive method of nRT-PCR, all other methods showed low sensitivity (6.4–10.2%). For all comparisons, the specificity was high (>95%) except for that of the nRT-PCR method (~83%), suggesting that nRT-PCR detected more infections than other methods, which can be expected given the large difference between the LOD of nRT-PCR and those of other methods, while the positives detected by the rest of the methods had significant overlaps. It is noteworthy that the CLIP-PCR method, despite increased throughput, had only modest sensitivity compared to LM and nD-PCR.

Table 2 Comparison of sensitivity and specificity of Plasmodium detection methods

The aforementioned sensitivity of different methods is consistent with their LODs. For nD-PCR, the LODs of all three samples were determined to be ~2 P. vivax parasites/µL. A 200-fold increase in sensitivity was observed for nRT-PCR, which had a LOD of 0.01 P. vivax parasites/µL for the three parasite samples. For CLIP-PCR using the 3D7 parasite lysate, the LOD was similarly low at 0.01 parasites/µL (Additional file 3). However, its LOD for P. vivax was not determined.

Prevalence of sexual stages of Plasmodium vivax

Given that the blood samples from the surveys contained mostly P. vivax infections, the presence of P. vivax gametocytes was further analysed. First, all 1005 blood samples were detected by RT-PCR targeting the Pvs25 gene, which detected a total of 61 P. vivax gametocyte-positive infections based on the 645 bp PCR product (Table 3). Of the 61 P. vivax gametocyte-positive infections, 33 were P. vivax 18S rRNA-positive cases and 28 were P. vivax-negative infections by all 18S rRNA gene-based molecular methods (Table 3). These latter samples may represent P. vivax infections with the presence of gametocytes but absence of asexual stages. When both 18S rRNA-based nRT-PCR and Pvs25-based RT-PCR were considered, the number of P. vivax-positive samples increased to 210, which also included six P. falciparum/P. vivax mixed infections.

Table 3 P. vivax gametocyte detection Pvs25 RT-PCR and parasite detection by other methods

The presence of gametocytes in the 210 P. vivax-positive blood samples was further evaluated using a more sensitive qRT-PCR based on Pvs25 mRNA. Based on the standard curve from the serially diluted Pvs25 plasmid (Additional file 4), the Ct value of <33 was used as the threshold for P. vivax gametocyte positivity. Of the 210 P. vivax samples, 115 were determined to be gametocyte-positive by qRT-PCR, and this confirmed the 61 Pvs25-positive samples by RT-PCR as gametocyte-positive (Table 4). Among them, 7/12 (58%) LM-positive, 11/19 (58%) CLIP-PCR-positive, 11/24 (46%) nD-PCR-positive, and 87/182 (47%) nRT-PCR-positive P. vivax infections harboured gametocytes detected by the Pvs25-based qRT-PCR. Whereas all gametocyte-positive samples detected by LM contained asexual-stage parasites, 28 gametocyte-positive samples detected by RT-PCR and qRT-PCR were not positive by the 18S rRNA-based methods. For the qRT-PCR, the LOD was estimated to be 3 copies/µL of plasmid (Additional file 4), while the estimate of LOD from three P. vivax gametocyte-positive samples was ~0.004 gametocyte/µL. The LOD for RT-PCR was 0.02 parasites/µL.

Table 4 Gametocyte detection by Pvs25 mRNA based detection (RT-PCR and qRT-PCR) in 210 P. vivax-positive samples and their overlaps with parasite detection by other methods

Discussion

Asymptomatic infections of malaria play an important role in sustaining transmission and present an obstacle to malaria elimination in low-endemicity regions [5]. Accurate knowledge of malaria epidemiology and transmission dynamics of the parasites in pre-elimination regions is critical for implementing effective and targeted control measures such as detect-and-treat and mass drug administration strategies. Low-cost, highly sensitive and specific screening tools for malaria are required for this purpose [44]. Molecular detection methods, though not suitable for field operations on a large scale, are normally applied in order to obtain representative assessment of the malaria situation in a subpopulation of an area. With the ease and speed of detection, PCR is a commonly used molecular tool and the detection limit is generally 50–100 times lower than those of LM and RDT [24, 4547]. CLIP-PCR recently has been developed with a claimed level of sensitivity as low as 0.01 parasites/µL and a much increased throughput that might be suitable for active screening of malaria parasites in low-transmission settings [36]. This study compared the sensitivity and specificity of both DNA- and RNA-based methods for detecting Plasmodium infections during cross-sectional surveys in an area of the Greater Mekong Subregion, which aims to eliminate malaria by 2030. This study identified that the two RNA-based detection methods, one for detecting Plasmodium 18S rRNA in asexual stages and the other for detecting the Pvs25 in gametocytes, were the most sensitive and detected a major proportion of the infections as submicroscopic.

WHO recommend LM as the ‘gold standard’ for symptomatic malaria, but its performance for detecting asymptomatic infections, especially under low endemic settings, is generally poor. In this survey, LM only detected 1.19% of the study population carrying asymptomatic P. vivax infections, which is consistent with prior reports of a threshold for LM of around 10 parasites/µL for a research setting [48] and 50–100 parasites/µL for outside a research setting [49]. Because of low parasite densities with the asymptomatic infections, LM is time-consuming and has much lower sensitivity than molecular methods. Thus, it is not favored for screening for asymptomatic infections in low-endemic settings like the present one.

Species-specific nD-PCR is a frequently used method in molecular epidemiological studies since parasite DNA can easily be preserved on filter papers, and cheap DNA-binding agents such as Chelex can be used for DNA extraction [50]. This method, in our hands, had a parasite detection limit of less than 2 parasites/µL, similar to an earlier report [6], and the number of infections detected was more than double that detected using LM. In comparison, nRT-PCR, based on the detection of asexual stage rRNA with a LOD of 0.01 parasites/µL blood, detected 18.61% of the study population as Plasmodium carriers. The presence of ~3500 18S rRNA transcripts in a single asexual parasite circulating in peripheral blood largely explains the superior sensitivity of nRT-PCR [26, 51]. Furthermore, this study extracted RNA directly from freshly collected blood samples, which may have improved the efficiency of RNA extraction.

This study specifically assessed the detection efficiency of the recently developed CLIP-PCR. Though this method had a LOD of as low as 0.01 parasites/µL of P. falciparum, it performed only slightly better than LM and detected 1.89% of the population carrying Plasmodium infections. First, the increased throughput means that significant pooling of the samples was used. With 500 tests in a 96-well plate, CLIP-PCR incurs significant pooling of the samples and dilution of the targets [36]. Second, this method used parasite RNA preserved on filter papers without the addition of any stabilizers, thus target degradation may also have accounted for the lower detection sensitivity. Third, the LOD was determined for P. falciparum, which might be different for P. vivax. Furthermore, the inferior performance of CLIP-PCR may be due to lower number of parasites used. For nD-PCR, RT-PCR, and nRT-PCR, the nucleic acids were extracted from 100 µL of whole blood. For nD-PCR, the amount of DNA used per reaction (4/30 µL of total DNA) corresponded to ~13 µL of whole blood, while the amount of RNA used for RT-PCR and nRT-PCR corresponded to ~1 µL of whole blood. In comparison, the CLIP-PCR used a 3-mm punch of dried filter paper, which is likely equivalent to <10 µL of whole blood. Nevertheless, CLIP-PCR demands further testing and improvement if future uses in molecular epidemiological studies in low endemic settings are considered. However, the lack of transparency on the design, and unavailable information about the sequences of the capture or detection probes and the kit components (of the assay lysis mixture, wash buffers, or ligation mix), hinder wide applications of this method [52].

With the predominant status of P. vivax infections in the study area, the presence of gametocytes also was evaluated with two RT-PCR methods targeting the Pvs25 transcripts. RT-PCR for Pvs25 detected gametocyte carriage in 6% (61/1005) of the study population, further increasing the P. vivax infection rate from 18% to 20%. Analysis of the P. vivax-positive samples from other methods by qRT-PCR targeting Pvs25 transcripts revealed 115 of them as gametocyte-positive. Interestingly, 101 of the 182 P. vivax-positive samples detected by nRT-PCR targeting the 18S rRNA were gametocyte-positive, whereas 28 samples were only Pvs25 positive. Negativity by nRT-PCR in a gametocyte-positive sample could be explained by the presence of significantly higher numbers of gametocytes (Pvs25 transcripts) than the asexual forms [43], which may have attributed to host conditions (including pH, drug, immunity, anaemia) that stimulate gametocyte formation and decrease asexual parasites [10, 53]. Nevertheless, the relatively high rates of gametocyte carriage suggest that a large proportion of the asymptomatic and submicroscopic infections may serve as important reservoirs of continued malaria transmission in this area of low endemicity.

This study identified the nRT-PCR method targeting the 18S rRNA as an extremely sensitive, robust, and scalable procedure for molecular surveillance. A considerable overlap of detected infections with Pvs25-based method further indicates the validity of this method. The sensitivity (LOD of 10 parasites/mL) is similar to the high-volume qPCR method (>20 parasites/mL) that uses venous blood [25], which is logistically difficult to conduct in large epidemiological studies. The availability of improved methods for conserving nucleic acids before processing will guarantee detection of malaria prevalence even in remote regions [19, 25, 26].

Conclusions

A survey method capable of identifying virtually every individual infected with Plasmodium parasites will be crucial in the malaria elimination phase. Comparison of LM with three molecular detection methods for parasite 18S rRNA genes and RT-PCR for the Pvs25 gene was conducted with samples from cross-sectional surveys in a malaria-hypoendemic area, which demonstrated the superior efficiency of nRT-PCR and qRT-PCR as surveillance tools to detect asexual parasite (18S rRNA) and gametocyte (Pvs25) infections, respectively. CLIP-PCR, though with the highest throughput among the molecular detection methods used, had a much lower sensitivity, which might be due to differences in the amount of the starting clinical samples used. This study showed a large proportion of Plasmodium-positive individuals as gametocyte carriers, highlighting the importance of transmission-interruption strategies for malaria elimination.