Summary
The response of an evaporative light scattering detector for the analysis of lipids is enhanced by the addition of triethylamine and an equimolar amount of formic acid to the mobile phase. The generality of this phenomenon was demonstrated for different chromatographic techniques and various classes of lipids: for non-aqueous liquid chromatography with a porous graphitic carbon packing for wax esters, fatty acid methyl esters and ceramides; for normal phase liquid chromatography with a PVA-Sil® stationary phase for cerebrosides, digalactosyl-diacylglycerols and phospholipids; and for subcritical chromatography with an octadecyl grafted silica column for ceramides. The response enhancement was quantified with cholesterol in non-aqueous liquid chromatography with a porous graphitic carbon packing. This response modifier enhances the detection response of lipids and does not significantly alter retention excepts in case of zwitterionic phospholipids.
Similar content being viewed by others
References
Myher, J.J.; Kuksis, A.J. Liquid Chromatogr. B 1995,671, 3–33.
Christie, W.W.J. lipid Res. 1985,26, 507–512.
Stolyhwo, A.; Martin, M.; Guiochon, G.J. Liquid Chromatogr. 1987,10, 1237–1253.
Robinson, L.; Macrae, R.J. Chromatogr. 1984,303, 386–390.
Heron, S.; Tchapla, A.J. Chromatography A 1999,848, 95–104.
Gaudin, K.; Chaminade, P.; Ferrier, D.; Baillet, A.; Tchapla, A.Chromatographia 1999,49, 241–248.
Gaudin, K.; Chaminade, P.; Ferrier, D.; Baillet, A.Chromatographia 2000,50, 470–478.
Charlesworth, J.M.Anal. Chem. 1978,50, 1414–1420.
Stolyhwo, A.; Colin, H.; Guiochon, G.J. Chromatogr. 1983,265, 1–18.
Mourey, T.H.; Oppenheimer, L.E.Anal. Chem. 1984,56, 2427–2434.
Vervoort, R.J.; Maris, F.A.; Hindriks, H.J. Chromatogr. 1992,623, 207–220.
Gaudin, K.; Chaminade, P.; Ferrier, D.; Baillet, A.J. Liquid Chromatogr. & related technologies 2000,23, 387–397.
Christie, W.W.HPLC and Lipids: A Practical Guide, Pergamon Press, Oxford,1987.
Gaudin, K.; Lesellier, E.; Chaminade, P.; Ferrier, D.; Baillet, A.; Tchapla, A.J. Chromatography A 2000,883, 211–222.
Deschamps, F.S.; Chaminade, P.; Baillet, A.J. Chromatogr. A 2001,928, 127–137.
Knox, H.; Ross, P.Advances Chromatogr. 1997,37, 73.
Lesellier, E.; Tchapla, A. chap. 7 inPacked column supercritical fluid chromatography, Ed. Berger, C. and Anton, K. Publ. Stubenrauch, J.; Dekker, M. Inc., New York, volume 75,1997.
Lesellier, E.; Tchapla, A.Anal. Chem. 1999,71, 5372–5378.
Gurdale, K.; Lesellier, E.; Tchapla, A.Anal. Chem. 1999,71, 2164–2170.
Christie, W.W.; Gill, S.; Nordback, J.; Itabashi, Y.; Sanda, S.; Slabas, A.R.Phytochem. Anal. 1998,9, 53–57.
Oppenheimer, L.E.; Mourey, T.H.J. Chromatogr. 1985,323, 297–304.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Deschamps, F.S., Gaudin, K., Lesellier, E. et al. Response enhancement for the evaporative light scattering detection for the analysis of lipid classes and molecular species. Chromatographia 54, 607–611 (2001). https://doi.org/10.1007/BF02492186
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF02492186