Determination of electroinactive organic acids in red wine by ion-exclusion chromatography using a poly-o-phenylenediamine film modified electrode

  • Originals
  • Column Liquid Chromatography
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

In this article, an ion-exclusion chromatography method combined with amperometric detection at a poly-o-phenylenediamine (POPD) film modified gold electrode provided a convenient analytical method for the determination of some electroinactive organic acids. The electrochemical behaviors of some aliphatic acids at POPD chemically modified electrode (CME) have been investigated by Differential Pulse Voltammetry (DPV). Under the optimum ion chromatographic conditions tartaric acid, citric acid, malic acid, formic acid, acetic acid and succinic acid could be separated in 15 min. The detection limits of these organic acids were 3.28×106 mol L−1 for tatartic acid, 3.62×106 mol L−1 forcitric acid, 3.84×106 mol L−1 for malic acid, 3.26×106 mol L1 for formic acid, 4.42×106 mol L1 for acetic acid and 3.66×106 mol L1 for succinic acid (S/N=3), respectively. The proposed method had been applied to the measurement the organic acids in red wine with satisfactory results. The electrode was very stable and there was no evidence of chemical and mechanical deterioration about 10 days.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Yang, M.H.; Choong, Y.M.Food Chem. 2001,204, 101–108.

    Article  Google Scholar 

  2. Jayaprakasha, G.K.; Sakariah, K.K.J. Pharm. Biomed. Anal 2002,28, 379–384.

    Article  CAS  Google Scholar 

  3. Patrick, A.W.V.H.; Johan, D.; Ulla, S.L.; Hans, B.; Bert, A.Talanta,1999,48, 173–179.

    Article  Google Scholar 

  4. Wu, C.H.; Lo, Y.S.; Lee, Y.H.; Lin, T.I.J. Chromatogr. A 1995,716, 291–301.

    Article  CAS  Google Scholar 

  5. Qiu, J.S.; Jin, X.H.J. Chromatogr. A,2002,950, 81–88.

    Article  CAS  Google Scholar 

  6. Sharma, A.K.; Clauss, S.A.; Mong, G.M.; Wahl, K.L.; Campbell, J.A.J. Chromatogr. A 1998,805, 101–107.

    Article  CAS  Google Scholar 

  7. Haginaka, J.; Waka, I.J.; Yasuda, H.J. Chromatogr. A 1988,447, 373–382.

    Article  CAS  Google Scholar 

  8. Lourdes, M.M.; Gustavo, G.A.; Troncoso, A.M.J Chromatogr. A 1998,882, 45–51.

    Google Scholar 

  9. Chen, Z.L.; Hibbert, D.B.J. Chromatogr. A,1997,766, 27–33.

    Article  CAS  Google Scholar 

  10. Zhou, J.X.; Wang, E.K.Talanta 1991,38, 547–555.

    Article  CAS  Google Scholar 

  11. Innocenzo, G.C.; Maria, G.J. Chromatogr. A 2001,912, 223–233.

    Article  Google Scholar 

  12. Martinusz, K.; Czirok, E.; Inzelt, G.J. Electroanal. Chem. 1994,379, 437–444.

    Article  Google Scholar 

  13. Martinusz, K.; Inzelt, G.; Horianyi, G.J. Electroanal. Chem. 1996,404, 143–148.

    Article  CAS  Google Scholar 

  14. Ogura, K.; Kokura, M.; Yano, J.; Shiigi, H.Electrochim. Acta 1995,40, 2707–2714.

    Article  CAS  Google Scholar 

  15. Palmisano, F.; Zambonin, P.G.Anal. Chem. 1993,65, 2690–2692.

    Article  CAS  Google Scholar 

  16. Malitesta, C.; Palmisano, F.; Torsi, L.; Zambonin, P.G.Anal. Chem. 1990,62, 2735–2740.

    Article  CAS  Google Scholar 

  17. Vidal, J.C.; Mendez, S.; Castillo, J.R.Anal. Chim. Acta 1999,385, 203–211.

    Article  CAS  Google Scholar 

  18. Martinusz, K.; Inzelt, G.; Horanyi, G.J. Electroanal. Chem. 1996,404, 143–148.

    Article  CAS  Google Scholar 

  19. Wu, L.L.; Luo, J.; Lin, Z.H.J. Electroanal. Chem. 1996,417, 53–58.

    Article  CAS  Google Scholar 

  20. Ikariyama, Y.; Heineman, W.R.Anal. Chem. 1986,58, 1803–1806.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Xu, J., Wang, Y., Xian, Y. et al. Determination of electroinactive organic acids in red wine by ion-exclusion chromatography using a poly-o-phenylenediamine film modified electrode. Chromatographia 57, 751–756 (2003). https://doi.org/10.1007/BF02491761

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02491761

Key Words

Navigation