Abstract
Introduction
A growing number of industrially manufactured implants have been developed in the last years for vertebral replacement in anterior cervical corpectomy and fusion (ACCF). Polyetheretherketone (PEEK)-cages are used in many centers, but outcome reports are scarce. This study assesses the clinical and radiological outcome after one- or two-level ACCF by the use of a PEEK-cage augmented by a plate–screw osteosynthesis.
Methods
A total of 21 patients received one-level (18 patients) or two-level (3 patients) ACCF by a PEEK-cage and plate–screw osteosynthesis for multilevel degenerative stenosis. The Visual Analogue Scale, Nurick Score, Neck Disability Index and European Myelopathy Score were used for clinical assessment. Radiological outcome—osseous fusion and loss of height—was evaluated by CT.
Results
The mean follow-up was 28 ± 12 months. In 19 patients, bony fusion was achieved after the primary operation. Graft failure that required surgical revision occurred in two patients. In these patients, osseous fusion was achieved after the second operation. Myelopathy improved significantly. The loss of height was 2.2 ± 2.3 and 5.3 ± 2.1 mm after one- and two-level ACCF, respectively.
Conclusion
Anterior corpectomy and fusion by a PEEK-cage and plate–screw osteosynthesis resulted in clinical improvement in all patients. Bony fusion was achieved in all patients in the long run. PEEK cages are allegedly less rigid than other xenografts. Similar to those, however, their use bears the risk of early cage-dislocation and subsidence. A comparison of industrial xenografts and autologous bone implants is required to challenge the different fusion techniques.
Similar content being viewed by others
References
Smith GW, Robinson RA (1958) The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am 40-A(3):607–624
Zdeblick TA, Bohlman HH (1989) Cervical kyphosis and myelopathy. Treatment by anterior corpectomy and strut-grafting. J Bone Joint Surg Am 71(2):170–182
Swank ML, Lowery GL, Bhat AL, McDonough RF (1997) Anterior cervical allograft arthrodesis and instrumentation: multilevel interbody grafting or strut graft reconstruction. Eur Spine J 6(2):138–143
Brown JA, Havel P, Ebraheim N, Greenblatt SH, Jackson WT (1988) Cervical stabilization by plate and bone fusion. Spine (Phila Pa1976) 13(3):236–240
Banwart JC, Asher MA, Hassanein RS (1995) Iliac crest bone graft harvest donor site morbidity. A statistical evaluation. Spine (Phila Pa1976) 20(9):1055–1060
Sawin PD, Traynelis VC, Menezes AH (1998) A comparative analysis of fusion rates and donor-site morbidity for autogeneic rib and iliac crest bone grafts in posterior cervical fusions. J Neurosurg 88(2):255–265
Gao R, Yang L, Chen H, Liu Y, Liang L, Yuan W (2012) Long term results of anterior corpectomy and fusion for cervical spondylotic myelopathy. PLoS 7(4):e34811
Uribe JS, Sangala JR, Duckworth EA, Vale FL (2009) Comparison between anterior cervical discectomy fusion and cervical corpectomy fusion using titanium cages for reconstruction: analysis of outcome and long-term follow-up. Eur Spine J 18(5):654–662
Edwards CC, Heller JG, Murakami H (2002) Corpectomy versus laminoplasty for multilevel cervical myelopathy: an independent matched-cohort analysis. Spine 27(11):1168–1175
Jiang SD, Jiang LS, Dai LY (2012) Anterior cervical discectomy and fusion versus anterior cervical corpectomy and fusion for multilevel cervical spondylosis: a systematic review. Arch Orthop Trauma Surg 132(2):155–161
Silber JS, Anderson DG, Daffner SD et al (2003) Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion. Spine (Phila Pa 1976) 28(2):134–139
Zairi F, Aboukais R, Thines L, Allaoui M, Assaker R (2012) Relevance of expandable titanium cage for the treatment of cervical spondylotic myelopathy. Eur Spine J 21(8):1545–1550
Woiciechowsky C (2005) Distractable vertebral cages for reconstruction after cervical corpectomy. Spine (Phila Pa 1976) 30(15):1736–1741
Waschke A, Kaczor S, Walter J, Duenisch P, Kalff R, Ewald C (2013) Expandable titanium cages for anterior column cervical reconstruction and their effect on sagittal profile: a review of 48 cases. Acta Neurochir (Wien) 155(5):801–807
Burkett CJ, Baaj AA, Dakwar E, Uribe JS (2012) Use of titanium expandable vertebral cages in cervical corpectomy. J Clin Neurosci 19(3):402–405
Castellvi AE, Castellvi A, Clabeaux DH (2012) Corpectomy with titanium cage reconstruction in the cervical spine. J Clin Neurosci 19(4):517–521
Chen Y, Chen D, Guo Y et al (2008) Subsidence of titanium mesh cage: a study based on 300 cases. J Spinal Disord Tech 21(7):489–492
Daubs MD (2005) Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating. Spine (Phila Pa 1976) 30(12):1402–1406
Kabir SM, Alabi J, Rezajooi K, Casey AT (2010) Anterior cervical corpectomy: review and comparison of results using titanium mesh cages and carbon fibre reinforced polymer cages. Br J Neurosurg 24(5):542–546
Chen JF, Lee ST, Wu CT (2010) A hollow cylindrical PMMA strut for cervical spine reconstruction after cervical multilevel corpectomy. J Spinal Disord Tech 23(5):321–327
Chen JF, Wu CT, Lee SC, Lee ST (2006) Hollow cylindrical polymethylmethacrylate strut for spinal reconstruction after single-level cervical corpectomy. J Neurosurg Spine 5(4):287–293
Andaluz N, Zuccarello M, Kuntz C (2012) Long-term follow-up of cervical radiographic sagittal spinal alignment after 1- and 2-level cervical corpectomy for the treatment of spondylosis of the subaxial cervical spine causing radiculomyelopathy or myelopathy: a retrospective study. J Neurosurg Spine 16(1):2–7
Toth JM, Wang M, Estes BT, Scifert JL, Seim HB, Turner AS (2006) Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 27(3):324–334
Katzer A, Marquardt H, Westendorf J, Wening JV, von Foerster G (2002) Polyetheretherketone—cytotoxicity and mutagenicity in vitro. Biomaterials 23(8):1749–1759
Niu CC, Liao JC, Chen WJ, Chen LH (2010) Outcomes of interbody fusion cages used in 1 and 2-levels anterior cervical discectomy and fusion: titanium cages versus polyetheretherketone (PEEK) cages. J Spinal Disord Tech 23(5):310–316
Cheung KM, Zhang YG, Lu DS, Luk KD, Leong JC (2003) Reduction of disc space distraction after anterior lumbar interbody fusion with autologous iliac crest graft. Spine (Phila Pa) 28(13):1385–1389
Kim MK, Kim SM, Jeon KM, Kim TS (2012) Radiographic comparison of four anterior fusion methods in two level cervical disc diseases: autograft plate fixation versus cage plate fixation versus stand-alone cage fusion versus corpectomy and plate fixation. J Korean Neurosurg Soc 51(3):135–140
Payer M (2006) Implantation of a distractible titanium cage after cervical corpectomy: technical experience in 20 consecutive cases. Acta Neurochir (Wien) 148(11):1173–1180
Rieger A, Holz C, Marx T, Sanchin L, Menzel M (2003) Vertebral autograft used as bone transplant for anterior cervical corpectomy: technical note. Neurosurgery 52(2):449–453
Dorai Z, Morgan H, Coimbra C (2003) Titanium cage reconstruction after cervical corpectomy. J Neurosurg Spine 99(1 Suppl):3–7
Acknowledgments
This work was not sponsored by private, industrial or governmental funding.
Conflict of interest
Dr. Westermaier received payments from Johnson & Johnson for teaching activities in spinal neurosurgery. None of the other authors has a conflict of interest to declare.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Raslan, F., Koehler, S., Berg, F. et al. Vertebral body replacement with PEEK-cages after anterior corpectomy in multilevel cervical spinal stenosis: a clinical and radiological evaluation. Arch Orthop Trauma Surg 134, 611–618 (2014). https://doi.org/10.1007/s00402-014-1972-1
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-014-1972-1