Leg exerciser for training of paralysed muscle by closed-loop control J. S. PetrofskyH. H. Heaton IIIC. A. Phillips OriginalPaper Pages: 298 - 303
Computer-controlled manipulator/display system for human-movement studies J. C. RuitenbeakR. J. Janssen OriginalPaper Pages: 304 - 308
Capacitive transducer for continuous measurement of vertical foot force S. MiyazakiA. Ishida OriginalPaper Pages: 309 - 316
Analysis of posturographic measurements on children H. PeetersE. BreslauH. Caberg OriginalPaper Pages: 317 - 321
Automatic method to detect and determine the preferential frequency of EMG signals from patients with pathological tremours H. L. JournéeJ. van Manen OriginalPaper Pages: 322 - 325
Interpretation of circulatory shunt-dilution curves as bimodal distribution functions J. L. M. MarinusC. H. MassenA. Versprille OriginalPaper Pages: 326 - 332
Analysis of gaseous exchange in open-circuit indirect calorimetry D. BrownT. J. ColeP. R. Murgatroyd OriginalPaper Pages: 333 - 338
Extraction of the constituent components of brain stem auditory evoked responses by a filtering and optimisation procedure J. G. Thomas OriginalPaper Pages: 339 - 342
Digital myoelectric signal processor with adaptive decision boundaries J. L. BérubéP. A. ParkerV. A. Dunfield OriginalPaper Pages: 349 - 352
Analysis of eye fixations during the diagnostic interpretation of chest radiographs J. P. J. de ValkE. G. J. Eijkman OriginalPaper Pages: 353 - 360
Electronic rotameter for quantitative evaluation of rotational behaviour in rats after unilateral lesions of the nigrostriatal dopamine system L. O. KehindeL. A. Buraimoh-IghoR. O. Makanjuola Technical Note Pages: 361 - 366
Conductimetric experiment to assay the haemoglobin content of blood P. S. NeelakantaswamyK. F. AsparN. P. Das Technical Note Pages: 367 - 370
Subtraction of 50 Hz interference from the electrocardiogram C. LevkovG. MichovI. K. Daskalov Technical Note Pages: 371 - 373
Coefficients of variation of two random variables,y andx, which are linked by a functional relationshipy=g(x) J. C. SpinelliG. V. SavinoM. E. Valentinuzzi Technical Note Pages: 374 - 376
Simulation of voltage clamp experiments with FET analogue circuits G. Roy Technical Note Pages: 377 - 378
Further precautions in the use of timedomain dielectric spectroscopy with biological and other lossy dielectrics F. X. Hart Technical Note Pages: 379 - 381
Dispositif simple utilisant un microprocesseur pour le relevé de l'activité locomotrice circadienne d'animaux M. BennetonR. RougnyB. Buisson Technical Note Pages: 382 - 384