Capacitive transducer for continuous measurement of vertical foot force

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A capacitive transducer is developed which continuously measures the vertical component of foot forces during walking. The transducer is shaped like an insole and consists of two subtransducer units, the front and rear. The outputs of the two units are summed to give the total force exerted by the foot. Each unit has a multilayered structure. The basic layer is a 2 mm Neoprene sponge sheet sandwiched by two 50 μm copper foils. They as a whole form a capacitor. The other two layers are a driving shield and static shield, which minimise the effect of stray capacitance and power-line noise, respectively. The transducer is thin (3·8 mm), light (90 g) and flexible and so does not hinder the natural gait pattern. It can be attached to the sale of the shoe easily by elastic bands and Velcro straps. The accuracy of the transducer is well within ±10 per cent of the full scale. An error analysis is made to clarify the change in sensitivity owing to a localised foad. The results are used to compensate for the inherent nonlinearity of the transducer units.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Craik, R. andWannstedt, G. (1975) The limb load monitor: an augmented sensory feedback. Proc. 2nd Conf. Devices & Systems for the Disabled, 19–24.

  • Durie, N. D. andShearman, L. (1979) A simplified limb load monitor.Physiotherapy Canada,31, 28–31.

    Google Scholar 

  • Hargreaves, P. andScales, T. (1975) Clinical assessment of gait using load measuring footwear.Acta Orthop. Scand.,46, 877–895.

    Article  Google Scholar 

  • Lord, M. (1981) Foot pressure measurement: a review of methodology.J. Biomed. Eng.,3, 91–99.

    Google Scholar 

  • Miyazaki, S. (1977) A four-channel PDM/FM telemetry system for continuous measurement of foot-forces during walking.Reports Inst. Med. Dent. Eng.,11, 77–87.

    MathSciNet  Google Scholar 

  • Miyazaki, S. andIwakura, H. (1978a) Foot-force measuring device for clinical assessment of pathological gait.Med. & Biol. Eng. & Comput.,16, 429–436.

    Google Scholar 

  • Miyazaki, S. andIwakura, H. (1978b) Limb-load alarm device for partial-weight-bearing walking exercise. —Ibid.,16, 500–506.

    Google Scholar 

  • Miyazaki, S., Takeuchi, T., Iwakura, H andKubota, T. (1983) Data processing of vertical foot forces for the clinical assessment of pathological gait. —Ibid.,21, 664–673.

    Google Scholar 

  • Miyazaki, S. andKubota, T. (1984) Quantification of gait abnormalities on the basis of continuous foot-force measurement: correlation between quantitative indices and visual rating. —Ibid.,22, 70–76.

    Google Scholar 

  • Nicol, K. andHenning, E. M. (1978) Measurement of pressure distribution by means of a flexible, large-surface mat. InBiomechanics VI-A, University Park Press, Baltimore, 374–380.

    Google Scholar 

  • Taylor, D., Wannstedt, G. andHerman, R. (1974) Biological feedback therapy for control of posture and gait.Progress Report Moss Rehabilitation Engineering Centre,3, 97–112.

    Google Scholar 

  • Winter, D. A. (1976) The locomotion laboratory as a clinical assessment system.Med. Progr. Technol.,4, 95–106.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Miyazaki, S., Ishida, A. Capacitive transducer for continuous measurement of vertical foot force. Med. Biol. Eng. Comput. 22, 309–316 (1984). https://doi.org/10.1007/BF02442098

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442098

Keywords

Navigation