Skip to main content
Log in

Web-based spectrum analysis software for photon activation analysis

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Photon activation analysis (PAA) includes extensive data evaluation that is sensitive to error. In order to save time and minimize human error, a new computer program—photon activation analysis system (PAAS)—was designed, built and implemented using the SQL language and Asp.net technology to analyze PAA data. Given peak information from PAA spectra and aided by a photonuclear data library, the program identifies the product isotopes, recognizes the possible nuclear reactions, and evaluates the concentration of target elements. Uncertainties of concentrations are estimated using standard error propagation techniques. The program can be accessed conveniently anywhere the internet is available and gives a fast and reliable determination of the trace elemental content of samples. Furthermore, this program also allow one to search its database for the information of general photonuclear reactions (e.g. energy lines, line intensities, target and product nuclides, photonuclear reactions, cross sections, natural abundance, etc.) and estimating the activity even before the activation begins. By switching the nuclide libraries, the program could also be expanded to neutron activation analysis and charged particle activation analysis (CPAA) without any difficulty. This program can be a versatile tool for the daily use of the nuclear and radiochemistry laboratories that conduct activation analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Notes

  1. One can note that there is no error propagation of mass in Eq. 3, because the mass information is cancelled out when one combines Eqs. 1 and 2 for the internal monitor method. However, for other methods in PAA, the error propagation on mass must be considered.

References

  1. Kenneth K (1988) Introductory nuclear physics. Wiley Inc., New York, pp 462–465, 789–794

  2. Segebade C, Weise H-P, Lutz GJ (1988) Photon activation analysis. Walter de Gruyter, Berlin, pp 13–17, 416–419

  3. Sun ZJ, Wells D, Segebade C, Green J (2010) Standardizing activation analysis: new software for photon activation analysis. AIP conference proceedings, May 2011, vol 1336

  4. Ni J, Block RC, Xu XG (2000) Photon activation analysis: a proof of principle using a NIST sediment standard and an electron accelerator at Rensselaer Polytechnic Institute. Appl Radiat Isot 53:535–540

    Article  CAS  Google Scholar 

  5. Yagi M, Masumoto K (1984) J Radioanal Nucl Chem 84:369–380

    Article  CAS  Google Scholar 

  6. The Lund/LBNL Nuclear Data Search, Version 2.0 (Feb 1999) http://nucleardata.nuclear.lu.se/NuclearData/toi/. Accessed 15 Sep 2010

Download references

Acknowledgments

This work was funded by the U.S. Department of Defense under grant No. DF-FC07-06 ID14780.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Z. J. Sun.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sun, Z.J., Segebade, C., Wells, D. et al. Web-based spectrum analysis software for photon activation analysis. J Radioanal Nucl Chem 291, 287–292 (2012). https://doi.org/10.1007/s10967-011-1209-5

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-011-1209-5

Keywords

Navigation