Abstract
Monitoring of cardiac output (CO) in the perioperative period and in seriously ill pediatric patients is of major importance for medical management. Hemodynamic monitoring, using transpulmonary thermodilution (TPTD) via a single thermal indicator injection, allows for measurements of CO, volumetric variables and extravascular lung water (EVLW). We describe and explain the influence of a left-to-right shunt on TPTD curve characteristics and EVLW measurements in a young child undergoing a surgical atrial septal defect repair. We suggest that these specific changes in the TPTD curve and the overestimation of EVLW detected by current device, in absence of gas exchange abnormalities, could be indicators of existing circulatory shunts in pediatric patients.
Similar content being viewed by others
References
Fakler U, Pauli C, Balling G, Lorenz HP, Eicken A, Hennig M, Hess J. Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery. J Thorac Cardiovasc Surg. 2007;133:224–8.
Proulx F, Lemson J, Choker G, Tibby SM. Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children. Pediatr Crit Care Med 2011 [Epub ahead of print].
Lemson J, Backx AP, van Oort AM, Bouw TP, van der Hoeven JG. Extravascular lung water measurement using transpulmonary thermodilution in children. Pediatr Crit Care Med. 2009;10:227–33.
Giraud R, Siegenthaler N, Park C, Beutler S, Bendjelid K. Transpulmonary thermodilution curves for detection of shunt. Intensive Care Med. 2010;36:1083–6.
Isakow W, Schuster DP. Extravascular lung water measurements and hemodynamic monitoring in the critically ill: bedside alternatives to the pulmonary artery catheter. Am J Physiol Lung Cell Mol Physiol. 2006;291:1118–31.
Pauli C, Fakler U, Genz T, Hennig M, Lorenz HP, Hess J. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle. Intensive Care Med. 2002;28:947–52.
Katzenelson R, Perel A, Berkenstadt H, Preisman S, Kogan S, Sternik L, Segal E. Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water. Crit Care Med. 2004;32(7):1550–4.
Newman EV, Merrell M, Genecin A, Monge C, Milnor WR, Mc KW. The dye dilution method for describing the central circulation. An analysis of factors shaping the time-concentration curves. Circulation. 1951;4:735–46.
Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg. 2010;110:799–811.
Nusmeier A, van der Hoeven JG, Lemson J. Interpretation of the transpulmonary thermodilution curve in the presence of a left-to-right shunt. Intensive Care Med. 2010;37:550–1.
Author information
Authors and Affiliations
Corresponding author
Additional information
Keller G, Desebbe O, Henaine R, Lehot J-J. Transpulmonary thermodilution in a pediatric patient with an intracardiac left-to-right shunt.
Rights and permissions
About this article
Cite this article
Keller, G., Desebbe, O., Henaine, R. et al. Transpulmonary thermodilution in a pediatric patient with an intracardiac left-to-right shunt. J Clin Monit Comput 25, 105–108 (2011). https://doi.org/10.1007/s10877-011-9281-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10877-011-9281-5