The Pt/Pd thermocouple has demonstrated superior thermoelectric drift and homogeneity performance over conventional Pt–Rh/Pt thermocouples. Here, we present a systematic comparison of the drift and homogeneity performance of Pt/Pd and Type R thermocouples by ageing the thermocouples at 1350 °C for a total of 500 h and measuring the performance at regular intervals during this time. The thermocouples studied were one Pt/Pd thermocouple, one Type R thermocouple and one ‘special’ Type R thermocouple which was given the same preparatory annealing treatment as the Pt/Pd thermocouple prior to use. The thermoelectric stability of each thermocouple was measured at the freezing point of Ag (961.78 °C) and the melting point of Co–C eutectic (1324.29 °C). The thermoelectric homogeneity of the thermocouples was also measured. Two difference methods were used by withdrawing the thermocouple from the Ag cell and by moving a localized heat source along the thermocouple. The long-term drift of the Pt/Pd thermocouple was around 50 mK (Ag) and 65 mK (Co–C) after the first 100 h ageing at 1350 °C, followed by a further 25 mK (Ag) and 35 mK (Co–C) over the subsequent 400 h ageing. This drift performance and inhomogeneity were an order of magnitude lower than for the two Type R thermocouples. The Type R thermocouple which was given the ‘special’ preparatory treatment was about 50 % more stable than the conventional Type R thermocouple.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G.W. Burns, D.C. Ripple, in Proceedings of TEMPMEKO 2001, 8th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by B. Fellmuth, J. Seidel, G. Scholz (VDE Verlag, Berlin, 2002), pp. 61–66

  2. Edler F., Morice R., Pearce J.: Int. J. Thermophys. 29, 199 (2008)

    Article  Google Scholar 

  3. Morice R., Edler F., Pearce J., Machin G., Fischer J., Filtz J.R.: Int. J. Thermophys. 29, 231 (2008)

    Article  Google Scholar 

  4. Ahmed M.G., Ali K.: Acta Metrol. Sin. 29, 179 (2008)

    Google Scholar 

  5. Jahan F., Ballico M.J.: Int. J. Thermophys. 28, 1822 (2007)

    Article  Google Scholar 

  6. Pearce J.V., Ogura H., Izuchi M., Machin G.: Metrologia 46, 473 (2009)

    Article  ADS  Google Scholar 

  7. Pearce J.V.: Acta Metrol. Sin. 29, 1 (2008)

    Google Scholar 

  8. Pearce J.V.: Meas. Sci. Technol. 18, 3489 (2007)

    Article  ADS  Google Scholar 

  9. Bentley R.E.: Thermocouples in Temperature Measurement. CSIRO, Sydney (2003)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to O. Ongrai.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ongrai, O., Pearce, J.V., Machin, G. et al. Comparative Study of Pt/Pd and Pt–Rh/Pt Thermocouples. Int J Thermophys 31, 1506–1516 (2010). https://doi.org/10.1007/s10765-010-0782-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-010-0782-0

Keywords

Navigation