The Dreissena-Monitor is a biological early warning system for the aquatic environment. It is based on the valve movements of up to 2 × 42 specimens of the zebra mussel Dreissena polymorpha, exposed in a flow-through system of 2 experimental channels connected to the water to be tested. A computer records whether a mussel is open or closed. After an analysis period of 5 min, the percentage of open mussels and the number of valve movements are computed as running averages for each experimental channel. With consideration being given to the normal behaviour of the mussels and the response of the system during several toxicity tests, reliable alarm-thresholds were established which are based on dynamic limits. In addition to these alarm functions (including the automatically safekeeping of a water sample) and the primary measurements, the computer fulfils every function necessary for an early warning system, e.g., complete storage and documentation of all data, validity-check of the primary measurements, and graphical presentation of all results. Together with more than 20 biological early warning systems, the Dreissena-Monitor was tested and evaluated by a joint federal government/federal states project group in Germany. As one of three systems, the Dreissena-Monitor is now recommended for implementation at the measuring stations of the ‘German Commission for the Protection of the Rhine Against Pollution.’ Starting in 1992, the Dreissena-Monitor is now applied at 13 water control stations in Germany (Rhine, Elbe, Danube, several tributaries). The experience of the users at the different stations have revealed that the Dreissena-Monitor complies quite well with the main functional requirements of an early warning system: (1) reliable, unattended operation for at least 1 week, (2) ease of handling, (3) an average of less than 3 h of maintenance per week, and (4) automatic detection of alarm situations within 30 min. In particular, the Dreissena-Monitor detected some water alarms at different rivers that give first clues on the sources of emission.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • D. M. M. Adema G. J. Vink (1981) ArticleTitleA comparitive study of the toxicity of 1,1,2−trichlorethane, dieldrin, pentachlorophenol and 3,4-dichloraniline for marine and fresh water organisms Chemosphere 10 533–554 Occurrence Handle1:CAS:528:DyaL3MXkvFWqsL4%3D

    CAS  Google Scholar 

  • H. J. Allen W. T. Waller M. F. Acevedo E. L. Morgan K. L. Dickson J. H. Kennedy (1996) ArticleTitleA minimally invasive technique to monitor valve-movement behavior in bivalves Environmental Technology 17 501–507 Occurrence Handle1:CAS:528:DyaK28XjtVOhtbc%3D Occurrence Handle10.1080/09593331708616411

    Article  CAS  Google Scholar 

  • J. Borcherding (1992a) Another early warning system for the detection of toxic discharges in the aquatic environment based on valve movements of the freshwater mussel Dreissena polymorpha D. Neumann H. A. Jenner (Eds) The Zebra Mussel Dreissena polymorpha – Ecology, Biological Monitoring and First Applications in the Water Quality Management Gustav Fischer Verlag, Stuttgart Jena, New York 127–146

    Google Scholar 

  • J. Borcherding (1992b) Die Schalenbewegungen der Muschel Dreissena polymorpha als Monitorsystem zur Gewässerüberwachung P. D. Hansen K. G. Steinhäuser (Eds) Biologische Testverfahren – Beiträge zu den Biotest-Statusseminaren 1989 und 1992, Nr. 89 Gustav Fischer Verlag Stuttgart 361–373

    Google Scholar 

  • J. Borcherding (1994) The “Dreissena-Monitor” – Improved evaluation of dynamic limits for the establishment of alarm-thresholds during toxicity tests and for continuous water control I. A. Hill F. Heimbach P. Leeuwangh P. Matthiesen (Eds) Freshwater Field Tests for Hazard Assessment of Chemicals Lewis Publishers Boca Raton 477–484

    Google Scholar 

  • Borcherding, J., 1996. Möglichkeiten und Grenzen biologischer Frühwarnsysteme in der ökotoxikologischen Forschung und der kontinuierlichen Gewässerüberwachung dargestellt am Beispiel des Dreissena-Monitors. In Deutsche Gesellschaft für Limnologie (ed.), Tagungsbericht 1995 (Berlin) H. Kaltenmeier Söhne, Krefeld: 843–846.

  • J. Borcherding B. Jantz (1997) ArticleTitleValve movement response of the mussel Dreissena polymorpha – the influence of pH and turbidity on the acute toxicity of pentachlorophenol under laboratory and field conditions Ecotoxicology 6 153–165 Occurrence Handle10.1023/A:1018666525205 Occurrence Handle1:CAS:528:DyaK2sXks1Sqtr8%3D

    Article  CAS  Google Scholar 

  • J. Borcherding M. Volpers (1994a) Der “Dreissena- Monitor” – Erfahrungen mit dem neuen biologischen Frühwarnsystem H. J. Pluta J. Knie R. Leschber (Eds) Biomonitore in der Gewässerüberwachung Gustav Fischer Verlag, Stuttgart Jena New York 119–123

    Google Scholar 

  • J. Borcherding M. Volpers (1994b) ArticleTitleDer Dreissena-Monitor – Untersuchungen zum Verhalten der Zebramuscheln im Rhein – Störfallbewertung in der kontinuierlichen Gewässerüberwachung Wasser & Boden 8/1994 25–30

    Google Scholar 

  • J. Borcherding M. Volpers (1994c) ArticleTitleThe Dreissena-monitor – 1st results on the application of this biological early warning system in the continuous monitoring of water quality Water Science and Technology 29 199–201

    Google Scholar 

  • J. Borcherding J. Wolf (2001) ArticleTitleThe influence of suspended particles on the acute toxicity of 2-chloro−4-Nitro-Aniline, cadmium, and pentachlorophenol on the valve movement response of the zebra mussel (Dreissena polymorpha) Archives of Environmental Contamination and Toxicology 40 497–504 Occurrence Handle11525492 Occurrence Handle1:CAS:528:DC%2BD3MXivVGhtL0%3D

    PubMed  CAS  Google Scholar 

  • InstitutionalAuthorNameBund/Länder-Projektgruppe ‘Wirkungstests Rhein’ (1994) Continuous Biotests for Water Monitoring of the River Rhine – Summary, Recommendations, Description of Tests Methods Umweltbundesamt Berlin 27

    Google Scholar 

  • InstitutionalAuthorNameBund/Länder-Projektgruppe ‘Wirkungstests Rhein’ (1995) Kontinuierliche Biotestverfahren zur Überwachung des Rheins Erich Schmidt Verlag Berlin 289

    Google Scholar 

  • N. Caspers (1988) ArticleTitleKritische Betrachtung des “Dynamischen Daphnientests” Zeitschrift für Wasser- und Abwasser-Forschung 21 152–154 Occurrence Handle1:CAS:528:DyaL1cXltlCmsb8%3D

    CAS  Google Scholar 

  • V. P. M. Englund M. P. Heino (1994) ArticleTitleValve movement of Anodonta anatina and Unio tumidus (Bivalvia, Unionidae) in a eutrophic lake Annales Zoologici Fennici 31 257–262

    Google Scholar 

  • Faust, J., 1995. Ökotoxikologische Untersuchungen mit dem Dreissena-Monitor unter besonderer Berücksichtigung des Einflusses von Schwebstoffen auf die Toxizität von 2-Chlor−4-Nitro-Anilin, Cadmium und Pentachlorphenol. Diploma Thesis Universität zu Köln.

  • V. Gerhardt J. Putzger (1992) Ein Biotest zur Gewässerüberwachung auf der Grundlage der verzögerten Fluoreszenz von Algen P. D. Hansen K. G. Steinhäuser (Eds) Biologische Testverfahren – Beiträge zu den Biotest-Statusseminaren 1989 und 1992, Nr. 89 Gustav Fischer Verlag Stuttgart 277–292

    Google Scholar 

  • D. Gruber C. H. Frago W. J. Rasnake (1994) ArticleTitleAutomated biomonitors – first line of defense Journal of Aquatic Ecosystem Health 3 87–92

    Google Scholar 

  • G. Gunkel (1994) Grundlagen der Bioindikation in aquatischen Systemen G. Gunkel (Eds) Biondikation in aquatischen Ökosystemen Gustav Fischer Verlag Jena, Stuttgart 15–83

    Google Scholar 

  • K. D. Ham M. J. Peterson (1994) ArticleTitleEffect of fluctuating low-level chlorine concentrations on valve-movement behavior of the asiatic clam (Corbicula fluminea) Environmental Toxicology and Chemistry 13 493–498 Occurrence Handle1:CAS:528:DyaK2cXit1Kht7g%3D

    CAS  Google Scholar 

  • Hantge, E., 1993. Wie sauber ist der Rhein? Bericht über die Wasserbeschaffenheit des Rheins in Rheinland-Pfalz. In Ministerium für Umwelt Rheinland-Pfalz (ed.), Die Biozönose des Rheins im Wandel – Lachs 2000? Advanced Biology Verlagsgesellschaft, Petersberg: 11–23.

  • H. A. Jenner F. Noppert T. Sikking (1989) ArticleTitleA new system for the detection of valve-movement response of bivalves Kema Scientific and Technical Reports 7 91–98 Occurrence Handle1:CAS:528:DyaL1MXlvVSgsrY%3D

    CAS  Google Scholar 

  • J. Knie (1978) ArticleTitleDer Dynamische Daphnientest – ein automatischer Biomonitor zur Überwachung von Gewässern Wasser and Boden 12 310–312

    Google Scholar 

  • K. J. M. Kramer J. Botterweg (1991) Aquatic biological early warning systems: an overview D. W. Jeffrey B. Madden (Eds) Bioindicators and Environmental Management Academic Press London 95–126

    Google Scholar 

  • K. J. M. Kramer E. M. Foekema (2001) The ‘Musselmonitor®’ as biological early warning system: the first decade F. M. Butterworth A. Gunatilaka M. E. Gonsebatt (Eds) Biomonitors and Biomarkers as Indicators of Environmental Change NumberInSeriesVol. 2 Kluwer Academic Publishers New York 59–87

    Google Scholar 

  • K. J. M. Kramer H. A. Jenner D. d. Zwart (1989) ArticleTitleThe valve movement response of mussels: a tool in biological monitoring Hydrobiologia 188 433–443

    Google Scholar 

  • Mader, E., 1993. Verhaltensregistrierungen bei der Zebramuschel Dreissena polymorpha mit Hilfe eines “Muschelmonitors”. Diploma Thesis Universität zu Köln.

  • Marten, M., 1997. Erfahrungen mit dem Routinebetrieb kontinuierlicher Biotest-Verfahren in der Gütemeßstation Karlsruhe am Rhein. In Deutsche Gesellschaft für Limnologie (ed.), Tagungsbericht 1996 (Schwedt) H. Kaltenmeier Söhne, Krefeld: 660–664.

  • U. Matthias S. Römpp (1994) ArticleTitleErprobung des Dreissena-Monitors, eines neuen Biotestsystems mit der Zebramuschel (Dreissena polymorpha), in der Rhein-Gütemeßstation Karlsruhe Acta Hydrochimica et Hydrobiologica 22 161–165 Occurrence Handle1:CAS:528:DyaK2cXms1aqtb8%3D

    CAS  Google Scholar 

  • J. Putzger V. Gerhardt (1994) Regensburger Leuchtbakterientest – Erweiterung des DF-Algentests zum on-line monitor mit Bacterium phosphoreum H. J. Pluta J. Knie R. Leschber (Eds) Biomonitore in der Gewässerüberwachung Gustav Fischer Verlag, Stuttgart Jena, New York 119–123

    Google Scholar 

  • Schmoeckel, A., 1995. Arbeits- und Qualitätssicherung für den␣Dreissena-Monitor in der Gewässergütemeßstation Schmilka (Elbe). Unpublished Station Report.

  • W. Slooff (1979) ArticleTitleDetection limits of a biological monitoring system based on fish respiration Bulletin of Environmental Contamination and Toxicology 23 517–523 Occurrence Handle497459 Occurrence Handle10.1007/BF01769997 Occurrence Handle1:CAS:528:DyaL3cXht1Kq

    Article  PubMed  CAS  Google Scholar 

  • R. L. Spehar H. P. Nelson M. J. Swanson J. W. Renoos (1985) ArticleTitlePentachlorophenol toxicity to amphipods and fathead minnows at different test pH values Environmental Toxicology and Chemistry 4 389–397 Occurrence Handle1:CAS:528:DyaL2MXksV2nsLo%3D

    CAS  Google Scholar 

  • W. J. Sydor W. R. Miller Iii J. Cairns SuffixJr D. Gruber (1982) ArticleTitleUse of box and line plots to assess fish ventilatory behaviour in biological monitoring systems Canadian Journal of Fisheries and Aquatic Sciences 39 1719–1722 Occurrence Handle10.1139/f82-227

    Article  Google Scholar 

  • J. Wolf L. Küchler J. Borcherding (2000) Der Dreissena-Monitor – ein Instrument zur kontinuierlichen Überwachung der Elbe an der Gewässergütemeßstation Schmilka A. Fomin U. Arndt D. Elsner A. Klumpp (Eds) 2. Hohenheimer Workshop zur Bioindikation “Biologische Testverfahren”, Altbach-Deizisau, Deutschland, 6–8.4.1998 Verlag Günter Heimbach Stuttgart 293–296

    Google Scholar 

  • D.d. Zwart K. J. M. Kramer H. A. Jenner (1995) ArticleTitlePractical experiences with the biological early warning system mosselmonitor Environmental Toxicology & Water Quality 10 237–247

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jost Borcherding.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Borcherding, J. Ten Years of Practical Experience with the Dreissena-Monitor, a Biological Early Warning System for Continuous Water Quality Monitoring. Hydrobiologia 556, 417–426 (2006). https://doi.org/10.1007/s10750-005-1203-4

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10750-005-1203-4

Keywords

Navigation