Skip to main content
Log in

Automatic calibration of the inlet pressure sensor for the implantable continuous-flow ventricular assist device

  • Original Article
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

Significant progress in the development of implantable ventricular assist devices using continuous-flow blood pumps has been made recently. However, a control method has not been established. The blood pressure in the inflow cannula (inlet pressure) is one of the candidates for performing an adequate control. This could also provide important information about ventricle sucking. However, no calibration method for an inlet pressure sensor exists. In this study, an automatic calibration algorithm of the inlet pressure sensor from the pressure waveform at the condition of ventricle sucking was proposed. The calibration algorithm was constructed based on the consideration that intrathoracic pressure could be substituted for atmospheric pressure because the lung is open to air. We assumed that the inlet pressure at the releasing point of the sucking would represent the intrathoracic pressure, because the atrial pressure would be low owing to the sucking condition. A special mock circulation system that can reproduce ventricle sucking was developed to validate the calibration algorithm. The calibration algorithm worked well with a maximum SD of 2.1 mmHg for 3-min measurement in the mock circulation system. While the deviation was slightly large for an elaborate calibration, it would still be useful as a primitive calibration. The influence of the respiratory change and other factors as well as the reliability of the calibration value should be investigated with an animal experiment as a next step.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  1. Takatani S, Matsuda H, Hanatani A, Nojiri C, Yamazaki K, Motomura T, Ohuchi K, Sakamoto T, Yamane T. Mechanical circulatory support devices (MCSD) in Japan: current status and future directions. J Artif Organs. 2005;8:13–27.

    Article  PubMed  Google Scholar 

  2. Koul B, Solem JO, Steen S, Casimir-Ahn H, Granfeldt H, Lonn UJ. HeartMate left ventricular assist device as bridge to heart transplantation. Ann Thorac Surg. 1998;65:1625–30.

    Article  PubMed  CAS  Google Scholar 

  3. Portner PM, Jansen PG, Oyer PE, Wheeldon DR, Ramasamy N. Improved outcomes with an implantable left ventricular assist system: a multicenter study. Ann Thorac Surg. 2001;71:205–9.

    Article  PubMed  CAS  Google Scholar 

  4. Mehta SM, Pae WE Jr, Rosenberg G, Snyder AJ, Weiss WJ, Lewis JP, Frank DJ, Thompson JJ, Pierce WS. The LionHeart LVD-2000: a completely implanted left ventricular assist device for chronic circulatory support. Ann Thorac Surg. 2001;71:S156–61. (discussion S183–184).

    Article  PubMed  CAS  Google Scholar 

  5. Nojiri C, Kijima T, Maekawa J, Horiuchi K, Kido T, Sugiyama T, Mori T, Sugiura N, Asada T, Umemura W, Ozaki T, Suzuki M, Akamatsu T, Westaby S, Katsumata T, Saito S. Development status of Terumo implantable left ventricular assist system. Artif Organs. 2001;25:411–3.

    Article  PubMed  CAS  Google Scholar 

  6. Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, Kurosawa H. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;50:461–5.

    Article  PubMed  Google Scholar 

  7. Frazier OH, Shah NA, Myers TJ, Robertson KD, Gregoric ID, Delgado R. Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation. Cardiology. 2004;101:111–6.

    Article  PubMed  CAS  Google Scholar 

  8. Chung MK, Zhang N, Tansley GD, Qian Y. Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump. Artif Organs. 2004;28:1089–94.

    Article  PubMed  Google Scholar 

  9. Nitta S, Katahira Y, Yambe T, Sonobe T, Hayashi H, Tanaka M, Sato N, Miura M, Mohri H, Esashi M. Micro-pressure sensor for continuous monitoring of a ventricular assist device. Int J Artif Organs. 1990;13:823–9.

    PubMed  CAS  Google Scholar 

  10. Bullister E, Reich S, d’Entremont P, Silverman N, Sluetz J. A blood pressure sensor for long-term implantation. Artif Organs. 2001;25:376–9.

    Article  PubMed  CAS  Google Scholar 

  11. Yamagishi H, Sankai Y, Yamane T, Jikuya T, Tsutsui T. Development of built-in type and noninvasive sensor systems for smart artificial heart. ASAIO J. 2003;49:265–70.

    Article  PubMed  Google Scholar 

  12. Saito I, Chinzei T, Isoyama T, Miura H, Kouno A, Ono T, Nakagawa H, Yamaguchi-Sekino S, Shi W, Inoue Y, Kishi A, Abe Y. Implementation of the natural heartbeat synchronize control for the undulation pump ventricular assist device using the inflow pressure. IFMBE Proceedings. 2008;19:62–5.

    Article  Google Scholar 

  13. Abe Y, Isoyama T, Saito I, Mochizuki S, Ono M, Nakagawa H, Taniguchi N, Mitsumune N, Sugino A, Mitsui M, Takiura K, Ono T, Kouno A, Chinzei T, Takamoto S, Imachi K. Development of mechanical circulatory support device at the University of Tokyo. J Artif Organs. 2007;10:60–70.

    Article  PubMed  Google Scholar 

  14. Imachi K, Mabuchi K, Chinzei T, Abe Y, Imanishi K, Yonezawa T, Nozawa H, Isoyama T, Kouno A, Ono T, Atsumi K, Iwao F. The jellyfish valve: a polymer membrane valve for the artificial heart. In: Akutsu T, Koyanagi H, editors. Heart replacement—artificial heart 4. Tokyo: Springer; 1993. p. 41–4.

    Google Scholar 

Download references

Acknowledgments

The study was supported in part by the Ishidsu Shun Memorial Scholarship and the JSPS KAKENHI (17209046 and 18200029).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yusuke Abe.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Shi, W., Saito, I., Isoyama, T. et al. Automatic calibration of the inlet pressure sensor for the implantable continuous-flow ventricular assist device. J Artif Organs 14, 81–88 (2011). https://doi.org/10.1007/s10047-011-0556-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-011-0556-x

Keywords

Navigation