Abstract

The current status and future directions of mechanical circulatory support devices (MCSDs) in Japan are reviewed. Currently used clinical MCSDs, both domestic and imported systems and continuous flow devices that are coming into the clinical arena are emphasized. Clinical MCSDs include the extracorporeal pulsatile Toyobo and Zeon systems and the implantable Novacor and HeartMate I VE. A thorough review is presented of single-ventricle continuous flow MCSDs such as the Terumo DuraHeart and the SunMedical EVAHEART and the biventricular Miwatec/Baylor systems that are on the horizon. The future directions in management of end-stage cardiac patients with MCSDs are discussed, focusing on (1) device selection – pulsatile versus continuous flow devices; (2) single-ventricle support, biventricular support, or replacement; (3) bridge to transplantation, destination therapy, or bridge to recovery; and (4) government regulatory processes and the medical industry. We hope to promote the quality of life (QOL) of end-stage cardiac patients as well as the medical industry in Japan.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. H Matsuda N Fukushima Y Sawa M Nishimura G Matsumiya R Shirakura (1999) ArticleTitleFirst brain dead donor heart transplantation under new legislation in Japan Jpn J Thorac Cardiovasc Surg 47 499–505 Occurrence Handle1:STN:280:DC%2BD3c%2Fit1Sksw%3D%3D Occurrence Handle10554420

    CAS  PubMed  Google Scholar 

  2. Japan Organ Transplant Network. Newsletter 7, 2003 (in Japanese)

  3. Omoto R, Kyo S, Nishimura M, Matsuda H, Matsumiya G, Kitamura S, Nakatani T, Takamoto S, Ono M, Tabayashi K, Yozu R. Japanese multicenter clinical evaluation of the HeartMateR VE left ventricular assist system. J Artif Organs 2005 (in press)

  4. EA Rose CG Annetine AJ Moskowitz DF Heitjan LW Stevenson W Dembitsky JW Long DD Ascheim AR Tierney RG Levitan JT Watson P Meier (2001) ArticleTitleLong-term use of a left ventricular assist device for end-stage heart failure New Eng J Med 345 IssueID20 1435–1443 Occurrence Handle10.1056/NEJMoa012175 Occurrence Handle1:STN:280:DC%2BD38%2FmsFGnsQ%3D%3D Occurrence Handle11794191

    Article  CAS  PubMed  Google Scholar 

  5. K Atsumi Y Sakurai E Atsumi S Narusawa S Kunisawa M Okikura S Kimoto (1963) ArticleTitleApplication of specially cross-linked natural rubber for artificial internal organs Trans ASAIO 9 324–331

    Google Scholar 

  6. H Takano Y Taenaka T Nakatani T Akutsu H Manabe (1985) ArticleTitleSuccessful treatment of profound left ventricular failure by automatic left ventricular assist system World J Surg 9 78–88 Occurrence Handle10.1007/BF01656259 Occurrence Handle1:STN:280:BiqC2s%2FhvFY%3D Occurrence Handle3984374

    Article  CAS  PubMed  Google Scholar 

  7. N Sato H Mohri Y Sezai H Koyanagi I Fujimasa K Imachi K Atsumi S Nitta M Miura (1990) ArticleTitleMulti-institutional evaluation of the Tokyo University ventricular assist system Trans ASAIO 36 M708–711 Occurrence Handle1:STN:280:By6D28bnvFE%3D

    CAS  Google Scholar 

  8. Patient implanted with a ventricular assist pump discharged home for the first time in Japan. Asahi Evening Newspaper Report, Sept 7, 1996

  9. C Nojiri T Kijima J Maekawa K Horiuchi T Kido T Sugiyama T Mori N Sugiura T Asada W Uemura T Ozaki M Suzuki T Akamatsu S Westaby T Katsumata S Saito (2001) ArticleTitleDevelopment status of Terumo implantable left ventricular assist system (T-ILVAS) J Artif Organs 25 411–413 Occurrence Handle10.1046/j.1525-1594.2001.025005411.x Occurrence Handle1:STN:280:DC%2BD3MzjsF2msQ%3D%3D

    Article  CAS  Google Scholar 

  10. T Motomura K Watanabe T Asai S Ito H Sumikura F Ichihashi T Shinohara D Taylor T Yamane T Kodama J Glueck Y Nose (2003) ArticleTitleHydraulic suspension gyro pump: A new generation gyro pump ASAIO J 49 IssueID2 177

    Google Scholar 

  11. E Tatsumi Y Taenaka A Homma T Nishinaka Y Takewa T Tsukiya H Ohnishi M Oshikawa Y Shirakawa Y Kakuta K Shioya N Katagiri T Mizuno T Kamimura H Takano K Tsukahara K Tsuchimoto H Wakui H Yamaguchi (2003) ArticleTitleThe National Cardiovascular Center electrohydraulic total artificial heart and ventricular assist device systems: current status of development ASAIO J 49 IssueID3 243–249 Occurrence Handle10.1097/01.MAT.0000065374.83106.FE Occurrence Handle12790371

    Article  PubMed  Google Scholar 

  12. K Yamazaki S Kihara T Akimoto O Tagusari A Kawai M Umezu J Tomioka RL Kormos BP Griffith H Kurosawa (2002) ArticleTitleEVAHEART: an implantable centrifugal blood pump for long-term circulatory support Jpn J Thorac Cardiovasc Surg 50 IssueID11 461–465 Occurrence Handle12478865

    PubMed  Google Scholar 

  13. T Yambe Y Abe K Imachi Y Shiraishi M Shibata T Yamaguchi Q Wang X Duan H Liu M Yoshizawa A Tanaka H Matsuki F Sato Y Haga M Esashi K Tabayashi Y Mitamura H Sasada M Umezu T Matsuda S Nitta (2004) ArticleTitleDevelopment of an implantable undulation type ventricular assist device for control of organ circulation Artif Organs 28 IssueID10 940–944 Occurrence Handle10.1111/j.1525-1594.2004.07382.x Occurrence Handle15385002

    Article  PubMed  Google Scholar 

  14. A Baba J Vasku P Dobsak I Saito M Ishimaru T Isoyama K Takiura T Ozeki Y Abe T Chinzei K Imachi (2003) ArticleTitlePathophysiologic study of goats with undulation pump total artificial heart: those that survived for more than 1 month ASAIO J 49 IssueID4 463–468 Occurrence Handle12918592

    PubMed  Google Scholar 

  15. S Takatani T Sakamoto K Ohuchi M Nakamura T Mizuno H Arai (2002) ArticleTitleOne-piece ultracompact total artificial heart for permanent use ASAIO J 48 538–545 Occurrence Handle10.1097/00002480-200209000-00017 Occurrence Handle12296576

    Article  PubMed  Google Scholar 

  16. S Takatani T Sakamoto (2000) ArticleTitleMechanical circulatory support devices for bridge to heart transplantation, bridge to recovery, or destination therapy J Artif Organs 3 75

    Google Scholar 

  17. T Nakatani H Takano (2003) ArticleTitleProgress in ventricular assist systems (VAS) and treatment of pump failure Nippon Rinsho 61 Suppl 5 472–477

    Google Scholar 

  18. T Matsuda H Takano K Hayashi Y Taenaka S Takaichi M Umezu T Nakamura H Iwata T Nakatani T Tanaka S Takatani T Akutsu (1984) ArticleTitleThe blood interface with segmented polyurethane: “multilayered protein passivation mechanism.” Trans ASAIO 30 353–357 Occurrence Handle1:CAS:528:DyaL2MXksF2ht7c%3D

    CAS  Google Scholar 

  19. H Takano T Nakatani (1996) ArticleTitleVentricular assist systems: experience in Japan with Toyobo pump and Zeon pump Ann Thorac Surg 61 IssueID1 317–322 Occurrence Handle10.1016/0003-4975(95)01007-6 Occurrence Handle1:STN:280:BymC2cnjs1U%3D Occurrence Handle8561597

    Article  CAS  PubMed  Google Scholar 

  20. EL Banayosy L Arusoglu L Kizner G Tenderich K Minami K Inoue R Korfer (2000) ArticleTitleNovacor left ventricular assist system versus HeartMate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients: a prospective study J Thorac Cardiovasc Surg 119 581–587 Occurrence Handle10694620

    PubMed  Google Scholar 

  21. K Minami EL Banayosy A Sezai L Anusoglu P Sarnowsky O Fey R Koerfer (2000) ArticleTitleMorbidity and outcome after mechanical ventricular support using Thoratec, Novacor and HeartMate, for bridging to heart transplantation Artif Organs 24 421–426 Occurrence Handle10.1046/j.1525-1594.2000.06621.x Occurrence Handle1:STN:280:DC%2BD3cvhslSgtg%3D%3D Occurrence Handle10886058

    Article  CAS  PubMed  Google Scholar 

  22. OH Frazier EA Rose MC Oz W Dembitsky P McCarthy B Radovancevic VL Poirier KA Dasse (2001) ArticleTitleHeartMate LVAS Investigators. Left ventricular assist system. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation J Thorac Cardiovasc Surg 122 1186–1195 Occurrence Handle10.1067/mtc.2001.118274 Occurrence Handle1:STN:280:DC%2BD3MjgtVCitg%3D%3D Occurrence Handle11726895

    Article  CAS  PubMed  Google Scholar 

  23. PM Portner PG Jansen PE Oyer DR Wheeldon N Ramasamy (2001) ArticleTitleImproved outcomes with an implantable left ventricular assist system: a multicenter study Ann Thorac Surg 71 205–209 Occurrence Handle10.1016/S0003-4975(00)02514-5 Occurrence Handle1:STN:280:DC%2BD3M7kvFOqtQ%3D%3D Occurrence Handle11216747

    Article  CAS  PubMed  Google Scholar 

  24. Y Okada T Masuzawa K Matsuda K Ohmori T Yamane Y Konishi S Fukahori S Ueno SJ Kim (2003) ArticleTitleAxial type self-bearing motor for axial flow blood pump Artif Organs 27 IssueID10 887–891 Occurrence Handle10.1046/j.1525-1594.2003.00030.x Occurrence Handle14616531

    Article  PubMed  Google Scholar 

  25. A Mitoh T Yano K Sekine Y Mitamura E Okamoto DW Kim R Yozu S Kawada (2003) ArticleTitleComputational fluid dynamics analysis of an intra-cardiac axial flow pump Artif Organs 27 IssueID1 34–40 Occurrence Handle10.1046/j.1525-1594.2003.07190.x Occurrence Handle12534711

    Article  PubMed  Google Scholar 

  26. C Nojiri T Kijima J Maekawa K Horiuchi T Kido T Sugiyama T Mori N Sugiura T Asada H Shimane K Nishimura T Ban T Akamatsu T Akutsu (1997) ArticleTitleMore than one year continuous operation of a centrifugal pump with a magnetically suspended impeller ASAIO J 43 M548–M552 Occurrence Handle1:STN:280:DyaK1c%2FisVChsg%3D%3D Occurrence Handle9360103

    CAS  PubMed  Google Scholar 

  27. C Nojiri T Kijima J Maekawa K Horiuchi T Kido T Sugiyama T Mori N Sugiura T Asada T Tanaka T Akamatsu (1999) ArticleTitleRecent progress in the development of Terumo implantable LVAS (T-ILVAS) ASAIO J 45 199–203 Occurrence Handle1:STN:280:DyaK1M3oslClug%3D%3D Occurrence Handle10360723

    CAS  PubMed  Google Scholar 

  28. K Nishimura S Kono S Nishina T Akamatsu T Tsukiya C Nojiri T Ozaki M Komeda (1998) ArticleTitleResutls of animal experiments with a new version of a magnetically suspended centrifugal pump ASAIO J 44 M725–M727 Occurrence Handle1:STN:280:DyaK1M%2FhvFKktA%3D%3D Occurrence Handle9804531

    CAS  PubMed  Google Scholar 

  29. C Nojiri T Kijima J Maekawa K Horiuchi T Kido T Sugiyama T Mori N Sugiura T Asada T Tanaka T Akamatsu (1999) ArticleTitleRecent progress in the development of Terumo implantable LVAS (T-ILVAS) ASAIO J 45 199–203 Occurrence Handle1:STN:280:DyaK1M3oslClug%3D%3D Occurrence Handle10360723

    CAS  PubMed  Google Scholar 

  30. C Nojiri T Kijima J Maekawa K Horiuchi T Kido T Sugiyama T Mori N Sugiura T Asada T Ozaki M Suzuki T Akamatsu T Akutsu (2000) ArticleTitleTerumo implantable left ventricular assist system (T-ILVAS): results of long-term animal study ASAIO J 46 117–122 Occurrence Handle10.1097/00002480-200001000-00027 Occurrence Handle10667729

    Article  PubMed  Google Scholar 

  31. S Saito S Westaby D Piggot T Katsumata S Dudnikov D Robson P Catarino C Nojiri (2001) ArticleTitleReliable long-term non-pulsatile circulatory support without anticoagulation Euro J Cardiothorac Surg 19 678–683 Occurrence Handle10.1016/S1010-7940(01)00640-6 Occurrence Handle1:STN:280:DC%2BD3M3ktF2ntQ%3D%3D

    Article  CAS  Google Scholar 

  32. S Saito S Westaby D Piggot S Dudnikov D Robson PA Catarino C Clelland C Nojiri (2002) ArticleTitleEnd-organ function during chronic nonpulsatile circulation Ann Thorac Surg 74 1080–1085 Occurrence Handle10.1016/S0003-4975(02)03846-8 Occurrence Handle12400749

    Article  PubMed  Google Scholar 

  33. K Yamazaki P Litwak O Tagusari K Kono M Kameneva M Watach L Gordon M Miyagishima J Tomioka M Umezu E Outa JF Antaki RL Kormos H Koyanagi BP Griffith (1998) ArticleTitleAn implantable centrifugal blood pump with a recirculating purge system (cool seal system) Artif Organs 22 466–474 Occurrence Handle10.1046/j.1525-1594.1998.06156.x Occurrence Handle1:STN:280:DyaK1czht1KrtQ%3D%3D Occurrence Handle9650667

    Article  CAS  PubMed  Google Scholar 

  34. S Kihara K Yamazaki KN Litwak P Litwak MV Kameneva H Ushiyama T Tokuno DC Borzelleca M Umezu J Tomioka O Tagusari T Akimoto H Koyanagi H Kurosawa RL Kormos BP Griffith (2003) ArticleTitleIn vivo evaluation of a MPC polymer-coated continuous flow left ventricular assist system Artif Organs 27 IssueID2 188–192 Occurrence Handle10.1046/j.1525-1594.2003.t01-2-06993.x Occurrence Handle12580778

    Article  PubMed  Google Scholar 

  35. T Akimoto KN Litwak K Yamazaki P Litwak S Kihara O Tagusari S Yamazaki MV Kameneva MJ Watach M Umezu J Tomioka RL Kormos H Koyanagi BP Griffith (2001) ArticleTitleThe role of diastolic pump flow in centrifugal blood pump hemodynamics Artif Organs 25 IssueID9 724–727 Occurrence Handle10.1046/j.1525-1594.2001.06864.x Occurrence Handle1:STN:280:DC%2BD3Mnotlahsw%3D%3D Occurrence Handle11722350

    Article  CAS  PubMed  Google Scholar 

  36. T Akimoto K Yamazaki P Litwak KN Litwak O Tagusari T Mori JF Antaki MV Kameneva MJ Watach M Umezu J Tomioka RL Kormos H Koyanagi BP Griffith (1999) ArticleTitleRotary blood pump flow spontaneously increases during exercise under constant pump speed: Results of a chronic study Artif Organs 23 IssueID8 797–801 Occurrence Handle10.1046/j.1525-1594.1999.06426.x Occurrence Handle1:STN:280:DyaK1MzptFWmsw%3D%3D Occurrence Handle10463510

    Article  CAS  PubMed  Google Scholar 

  37. Y Takami T Nakazawa K Makinouchi R Benkowski J Glueck Y Nose (1997) ArticleTitleMaterial of the double pivot bearing system in the Gyro C1E3 centrifugal pump Artif Organs 21 IssueID2 143–147 Occurrence Handle1:STN:280:ByiC1c%2Fjt1U%3D Occurrence Handle9028497

    CAS  PubMed  Google Scholar 

  38. G Ohtsuka K Nakata M Yoshikawa J Mueller T Takano S Yamane N Gronau J Glueck Y Takami A Sueoka G Letsou H Schima H Schmallegger E Wolner H Koyanagi A Fujisawa J Baldwin Y Nose (1998) ArticleTitleLong-term in vivo left ventricular assist device study with a titanium centrifugal pump ASAIO J 44 M619–M623 Occurrence Handle1:STN:280:DyaK1M%2FhvFKmtg%3D%3D Occurrence Handle9804509

    CAS  PubMed  Google Scholar 

  39. Y Nose K Nakata M Yoshikawa G Letsou A Fujisawa E Wolner H Schima (1999) ArticleTitleDevelopment of a totally implantable biventricular bypass centrifugal blood pump system Ann Thorac Surg 68 775–779 Occurrence Handle10.1016/S0003-4975(99)00528-7 Occurrence Handle1:STN:280:DyaK1Mvgt1CksA%3D%3D Occurrence Handle10475487

    Article  CAS  PubMed  Google Scholar 

  40. M Yoshikawa K Nonaka J Linneweber S Kawahito G Ohtsuka K Nakata T Takano S Schulte-Eistrup J Glueck H Schima E Wolner Y Nose (2000) ArticleTitleDevelopment of the NEDO implantable ventricular assist device with Gyro centrifugal pump Artif Organs 24 459–467 Occurrence Handle10.1046/j.1525-1594.2000.06595.x Occurrence Handle1:STN:280:DC%2BD3cvhslSnsA%3D%3D Occurrence Handle10886066

    Article  CAS  PubMed  Google Scholar 

  41. K Nonaka J Linneweber S Ichikawa T Motomura H Ishitoya I Nishimura D Oestmann J Glueck H Schima E Wolner T Shinohara Y Nose (2001) ArticleTitleDevelopment of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device Artif Organs 25 IssueID9 675–682 Occurrence Handle10.1046/j.1525-1594.2001.06855.x Occurrence Handle1:STN:280:DC%2BD3MnnsFOquw%3D%3D Occurrence Handle11722341

    Article  CAS  PubMed  Google Scholar 

  42. S Ichikawa K Watanabe Y Nose (2002) ArticleTitleThe fourth-generation centrifugal blood pump J Artif Organs 5 208–210 Occurrence Handle10.1007/s100470200039

    Article  Google Scholar 

  43. T Motomura K Watanabe T Asai S Ito T Shinohara A Hata K Yuri S Tsujimura J Glueck Y Nose (2003) ArticleTitleThe fully wearable paracorporeal LVAS: Total cost reduction of VAD patients ASAIO J 49 IssueID2 174

    Google Scholar 

  44. T Motomura K Watanabe T Asai S Ito H Sumikura F Ichihashi T Shinohara Y Nose (2003) ArticleTitleHydraulic suspension Gyro pump: A new generation Gyro pump ASAIO J 49 IssueID2 177

    Google Scholar 

  45. T Yamane T Kodama Y Yamamoto T Shinohara Nose (2004) ArticleTitleFlow visualization in a centrifugal blood pump with an eccentric inlet port Artif Organs 28 IssueID6 564–570 Occurrence Handle10.1111/j.1525-1594.2004.07290.x Occurrence Handle15153149

    Article  PubMed  Google Scholar 

  46. LR Golding G Jacobs T Murakami S Takatani F Valdes H Harasaki Y Nose (1980) ArticleTitleChronic nonpulsatile blood flow in an alive, awake animal with 34-day survival Trans ASAIO 26 251–254 Occurrence Handle1:STN:280:Bi6B38jksVM%3D

    CAS  Google Scholar 

  47. S Takatani K Ozawa LR Golding G Jacobs T Murakami F Valdes H Harasaki R Kiraly Y Nose (1980) ArticleTitleComparative evaluation of pulsatile and nonpulsatile cardiac prostheses Trans ASAIO 26 438–443 Occurrence Handle1:STN:280:Bi6B38jkvFQ%3D

    CAS  Google Scholar 

  48. I Yada LR Golding H Harasaki G Jacobs S Koike R Yozu N Sato LK Fujimoto J Snow E Olsen S Murabayashi VS Venkatesen R Kiraly Y Nose (1983) ArticleTitlePhysiopathological studies of nonpulsatile blood flow in chronic models Trans ASAIO 29 520–525 Occurrence Handle1:STN:280:BiuC2sznslQ%3D

    CAS  Google Scholar 

  49. R Tominaga WA Smith A Massiello H Harasaki LA Golding (1994) ArticleTitleChronic nonpulsatile blood flow: I. Cerebral autoregulation in chronic nonpulsatile biventricular bypass: carotid blood flow response to hypercapnia J Thorac Cardiovasc Surg 108 907–912 Occurrence Handle1:STN:280:ByqD2Mjit1E%3D Occurrence Handle7967674

    CAS  PubMed  Google Scholar 

  50. R Tominaga WA Smith A Massiello H Harasaki LA Golding (1996) ArticleTitleChronic nonpulsatile blood flow: II. Hemodynamic responses to progressive exercise in calves with chronic nonpulsatile biventricular bypass J Thorac Cardiovasc Surg 111 857–862 Occurrence Handle1:STN:280:BymC1cvjs1Q%3D Occurrence Handle8614147

    CAS  PubMed  Google Scholar 

  51. R Tominaga WA Smith A Massiello H Harasaki LA Golding (1996) ArticleTitleChronic nonpulsatile blood flow: III. Effects of pump flow rate on oxygen transport and utilization in chronic nonpulsatile biventricular bypass J Thorac Cardiovasc Surg 111 863–872 Occurrence Handle1:STN:280:BymC1cvjs1U%3D Occurrence Handle8614148

    CAS  PubMed  Google Scholar 

  52. A Undar (2004) ArticleTitleMyths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support Artif Organs 28 IssueID5 439–443 Occurrence Handle10.1111/j.1525-1594.2004.00086.x Occurrence Handle15113337

    Article  PubMed  Google Scholar 

  53. A Undar (2003) ArticleTitleEnergy equivalent pressure formula is for precise quantification of different perfusion models (Letter) Ann Thorac Surg 76 1777–1778 Occurrence Handle10.1016/S0003-4975(03)00668-4

    Article  Google Scholar 

  54. OH Frazier NA Shah TJ Myers KD Robertson ID Gregoric R Delgado (2004) ArticleTitleUse of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation Cardiology 101 IssueID1–3 111–116 Occurrence Handle10.1159/000075991 Occurrence Handle1:STN:280:DC%2BD2c%2FpslGgsA%3D%3D Occurrence Handle14988632

    Article  CAS  PubMed  Google Scholar 

  55. HH Weitkemper A El-Banayosy L Arusoglu P Sarnowski R Korfer (2004) ArticleTitleMechanical circulatory support: reality and dreams experience of a single center J Extracorpor Technol 36 IssueID2 169–173 Occurrence Handle1:STN:280:DC%2BD2cvivFChtw%3D%3D

    CAS  Google Scholar 

  56. DJ Goldstein (2003) ArticleTitleWorldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation Circulation 108 II–272 Occurrence Handle10.1161/01.cir.0000087387.02218.7e

    Article  Google Scholar 

  57. R Hetzer Y Weng EV Potapov M Pasic T Drews M Jurmann E Hennig J Muller (2004) ArticleTitleFirst experiences with a novel magnetically suspended axial flow left ventricular assist device Eur J Cardiothorac Surg 25 IssueID6 964–970 Occurrence Handle10.1016/j.ejcts.2004.02.038 Occurrence Handle15144996

    Article  PubMed  Google Scholar 

  58. K Doi LA Golding AL Massiello MW Kopcak SuffixJr RL Gerhart S Schenk M Inoue Y Ootaki K Fukamachi (2004) ArticleTitlePreclinical readiness testing of the Arrow International CorAide left ventricular assist system Ann Thorac Surg 77 IssueID6 2103–2110 Occurrence Handle10.1016/j.athoracsur.2003.07.048 Occurrence Handle15172276

    Article  PubMed  Google Scholar 

  59. NL James AL van der Meer GA Edwards SR Snelling JD Begg DS Esmore JC Woodard (2003) ArticleTitleImplantation of the VentrAssist implantable rotary blood pump in sheep ASAIO J 49 IssueID4 454–458 Occurrence Handle12918590

    PubMed  Google Scholar 

  60. The RELIANT (R_andomized E_valuation of the Novacor L_VAS I_n A_ N_on-T_ransplant Population) Clinical Trial compares leading LVAS devices. (www.worldheart.com/clinical_information/clinical_trials.cfm)

  61. Boehmer JP. Destination therapy with a totally implantable left ventricular assist device system: Results of the LionHeart CUBS trial. (www.hmc.psu.edu/lionheart/downloads/newsBoehmer1203)

  62. RD Dowling AS Ghaly LA Gray SuffixJr (2004) ArticleTitleCreation of a diaphragm patch to facilitate placement of the AbioCor implantable replacement heart Ann Thorac Surg 77 IssueID5 1849–1850 Occurrence Handle10.1016/j.athoracsur.2003.07.026 Occurrence Handle15111212

    Article  PubMed  Google Scholar 

  63. RD Dowling LA Gray SuffixJr SW Etoch H Laks D Marelli L Samuels J Entwistle G Couper GJ Vlahakes OH Frazier (2004) ArticleTitleInitial experience with the AbioCor implantable replacement heart system J Thorac Cardiovasc Surg 127 IssueID1 131–141 Occurrence Handle10.1016/j.jtcvs.2003.07.023 Occurrence Handle14752423

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Setsuo Takatani PhD, DMed.

Additional information

This article is a summary review of the Rotary Blood Pump Symposium held on August 27, 2004, Tokyo, Japan

Rights and permissions

Reprints and permissions

About this article

Cite this article

Takatani, S., Matsuda, H., Hanatani, A. et al. Mechanical circulatory support devices (MCSD) in Japan: current status and future directions. J Artif Organs 8, 13–27 (2005). https://doi.org/10.1007/s10047-004-0284-6

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-004-0284-6

Key words

Navigation