Abstract
The authors describe a fluorescence polarization (FP) based strategy for HIV detection. The assay is based on T7 exonuclease assisted quadratic recycling amplification using graphene oxide (GO) as an amplifier of FP. The effect is caused by the finding that the binding forces between GO and ssDNA are much stronger than those between GO and dsDNA. The two probes, P1 and dye labeled P2, resist digestion by T7 exonuclease (T7exo) due to the 5′-termini protrusion. The hairpin probes are absorbed on the surface of GO without the target DNA. While the presence of the target DNA leads to two independent and simultaneous recycling processes with the assistance of T7exo. Due to this quadratic amplification, a large quantity of ssDNA will be absorbed onto the surface of GO, and this will cause a strong enhancement of FP. This polarization assay was applied to design a method for the determination of HIV DNA which displays a detection limit of 9.12 pmol·L−1. It is highly selective and can be performed in homogeneous solutions. The cascade amplification strategy is not limited to this particular DNA but is perceived to provide a universal platform for sensitive determination of a wide spectrum of DNA target analytes.
Similar content being viewed by others
References
Fatin MF, Ruslinda AR, MdArshad MK, Tee KK, Ayub RM, Hashim U, Kamarulzaman A, Gopinath SCB (2016) HIV-1 Tat biosensor: current development and trends for early detection strategies. Biosen Bioelectron 78:358–366
Guo Y, Chen JH, Chen GN (2013) A label-free electrochemical biosensor for detection of HIV related gene based on interaction between DNA and protein. Sensor Actuat B-Chem 184:113–117
Gong QJ, Yang HY, Dong YY, Zhang WC (2015) A sensitive impedimetric DNA biosensor for the determination of the HIV gene based on electrochemically reduced graphene oxide. Anal Method 7:2554–2562
Wu JB, Kodzius R, Cao WB, Wen WJ (2014) Extraction, amplification and detection of DNA in microfluidic chip-based assays. Microchim Acta 181:1611–1631
Khodakov DA, Ellis AV (2014) Recent developments in nucleic acid identification using solid-phase enzymatic assays. Microchim Acta 181:1633–1646
Huang JH, Gao X, Jia JJ, Kim JK, Li ZG (2014) Graphene Oxide-Based amplified fluorescent biosensor for Hg2+ detection through hybridization chain reactions. Anal Chem 86:3209–3215
Ding CF, Wang NN, Zhang J, Wang ZF (2013) Rolling circle amplification combined with nanoparticle aggregates for highly sensitive identification of DNA and cancer cells. Biosens Bioelectron 42:486–491
Gao ZF, Ling Y, Lu L, Chen NY, Luo HQ, Li NB (2014) Detection of single -nucleotide polymorphisms using an on-off switching of regenerated biosensor based on a locked nucleic acid-integrated and toehold-mediated strand displacement reaction. Anal Chem 86:2543–2548
Zhao HZ, Dong JJ, Zhou FL, Li BX (2015) G-quadruplex − based homogenous fluorescence platform for ultrasensitive DNA detection through isothermal cycling and cascade signal amplification. Microchim Acta 182:2495–2502
Cai ZM, Chen YY, Lin CS, Wu YF, Yang CYJ, Wang YR, Chen X (2014) A dual-signal amplification method for the DNA detection based on exonuclease III. Biosens Bioelectron 61:370–373
Liu SF, Cheng CB, Liu T, Wang L, Gong HW, Li F (2015) Highly sensitive fluorescence detection of target DNA by coupling exonuclease-assisted cascade target recycling and DNAzyme amplification. Biosens Bioelectron 63:99–104
Zhang YL, Tang LN, Yang F, Sun ZY, Zhang GJ (2015) Highly sensitive DNA-based fluorometric mercury(II) bioassay based on graphene oxide and exonuclease III-assisted signal amplification. Microchim Acta 182:1535–1541
Yang ZQ, Xie LY, Yin HS, Zhou YL, Ai SY (2015) Methyltransferase activity assay based on the use of exonuclease III, the hemin/G-quadruplex system and reduced graphene oxide on a gold electrode, and a study on enzyme inhibition. Microchim Acta 182:2607–2613
Huang Y, Chen J, Zhao SL, Shi M, Chen ZF, Liang H (2013) Label-free colorimetric aptasensor based on nicking enzyme assisted signal amplification and DNAzyme amplification for highly sensitive detection of protein. Anal Chem 85:4423–4430
Zhang H, Li MX, Li CH, Guo ZH, Dong HL, Wu P, Cai CX (2015) G-quadruplex DNAzyme-based electrochemiluminescence biosensing strategy for VEGF165 detection: Combination of aptamer–target recognition and T7exonuclease-assisted cycling signal amplification. Biosens Bioelectron 74:98–103
Zhang P, Zhuo Y, Chang YY, Yuan R, Chai YQ (2015) Electrochemiluminescent graphene quantum dots as a sensing platform: a dual amplification for microRNA assay. Anal Chem 87:10385–10391
Cui L, Zhu Z, Lin NH, Zhang HM, Guan ZC, Yang CYJ (2014) A T7 exonuclease-assisted cyclic enzymatic amplification method coupled with rolling circle amplification: a dual-amplification strategy for sensitive and selective microRNA detection. Chem Commun 50:1576–1578
McCarroll ME, Billiot FH, Warner IM (2001) Fluorescence anisotropy as a measure of chiral recognition. J Am Chem Soc 123:3173–3174
Huang Y, Shi M, Zhao LM, Zhao SL, Hu K, Chen ZF (2014) Carbon nanotube signal amplification for ultrasensitive fluorescence polarization detection of DNA methyltransferase activity and inhibition. Biosens Bioelectron 54:285–291
Zhang M, Guan YM, Ye BC (2011) Ultrasensitive fluorescence polarization DNA detection by target assisted exonuclease III-catalyzed signal amplification. Chem Commun 47:3478–3480
He YC, Yin BC, Jiang LH, Ye BC (2014) The rapid detection of microRNA based on p19-enhanced fluorescence polarization. Chem Commun 50:6236–6239
Zhang JN, Tian JN, He YL, Chen S, Jiang YX, Zhao YC (2013) Protein-binding aptamer assisted signal amplification for the detection of influenza A (H1N1) DNA sequences based on quantum dot fluorescence polarization analysis. Analyst 138:4722–4727
Zhu ZY, Ravelet C, Perrier S, Guieu V, Fiore E, Peyrin E (2012) Single-stranded DNA binding protein-assisted fluorescence polarization aptamer assay for detection of small molecules. Anal Chem 84:7203–7211
Ye BC, Yin BC (2008) Highly sensitive detection of mercury (II) ions by fluorescence polarization enhanced by gold nanoparticles. Angew Chem Int Ed 47:8386–8389
Yue QL, Shen TF, Wang L, Xu SL, Li HB, Xue QW (2014) A convenient sandwich assay of thrombin in biological media using nanoparticle enhanced fluorescence polarization. Biosens Bioelectron 56:231–236
Huang Y, Liu XQ, Zhang LL, Hu K, Zhao SL, Fang BZ, Chen ZF, Liang H (2015) Nicking enzyme and grapheme oxide-based dual signal amplification for ultrasensitive aptamer-based fluorescence polarization assays. Biosens Bioelectron 63:178–184
Liu JH, Wang CY, Jiang Y, Hu YP, Li JS, Yang S, Li YH, Yang RH, Tan WH, Huang CZ (2013) Graphene signal amplification for sensitive and real-time fluorescence anisotropy detection of small molecules. Anal Chem 85:1424–1430
Zhen SJ, Yu Y, Li CM, Huang CZ (2015) Graphene oxide amplified fluorescence anisotropy for label-free detection of potassium ion. Analyst 140:353–357
Lu YX, Kong H, Wen F, Zhang SC, Zhang XR (2013) Lab-on-graphene: graphene oxide as a triple-channel sensing device for protein discrimination. Chem Commun 49:81–83
Liu BW, Sun ZY, Zhang X, Liu JW (2013) Mechanisms of DNA sensing on graphene oxide. Anal Chem 85:7987–7993
Lu CH, Yang HH, Zhu CL, Chen X, Chen GN (2009) A graphene platform for sensing biomolecules. Angew Chem Int Ed 48:4785–4787
Liu ZB, Chen SS, Liu BW, Wu JP, Zhou YB, He LY, Ding JS, Liu JW (2014) Intracellular detection of ATP using an aptamer beacon covalently linked to graphene oxide resisting nonspecific probe displacement. Anal Chem 86:12229–12235
Acknowledgments
This work has been supported by National Natural Science Foundation of China (No. 21165004, 21163002, 21465007), the Guangxi Natural Science Foundation of China (2010GXNSFF013001, 2012GXNSFBA053022), and the project of Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources(Guangxi Normal University), Ministry of Education of China(CMEMR2014-A08).
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
The authors declare that they have no competing interests.
Electronic supplementary material
ESM 1
(DOC 363 kb)
Rights and permissions
About this article
Cite this article
Wang, L., Tian, J., Huang, Y. et al. Homogenous fluorescence polarization assay for the DNA of HIV A T7 by exploiting exonuclease-assisted quadratic recycling amplification and the strong interaction between graphene oxide and ssDNA. Microchim Acta 183, 2147–2153 (2016). https://doi.org/10.1007/s00604-016-1844-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-016-1844-1