Skip to main content
Log in

Accurate assessment of in situ isometric contractile properties of hindlimb plantar and dorsal flexor muscle complex of intact mice

  • Instruments and Techniques
  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Abstract.

An isometric torque sensor for measuring in situ contractions of plantar or dorsal flexors of intact mouse hindlimb has been developed and evaluated. With this device, muscle torque can be accurately measured within the range of –14 mN·m to +14 mN·m. Special attention was paid to fixation of the mouse hindlimb to the measurement device. Halothane-anaesthetized Swiss wild-type mice were positioned on the thermostatic measurement platform, and fixated with a hip and foot fixation system. The novel fixation unit was evaluated by measuring knee and ankle displacements during a contraction. A mathematical muscle model was used to quantify the effects of these displacements on the contractile parameters. Measured ankle and knee displacement, due to non-absolute fixation, resulted in a calculated muscle fibre shortening of 2.5%. Simulations of a contraction with this degree of fibre shortening, using the mathematical muscle model, showed only minor effects on maximal torque generation and the temporal parameters (half-relaxation time and 10–50% rise time). Furthermore, we showed that muscle torque in our set-up is hardly affected by eccentricity between ankle and measurement axis. Measured tetanic muscle torques of intact dorsal and plantar flexors were 3.2±0.4 mN·m and 11.8±1.6 mN·m, respectively. The half-relaxation time of plantar flexors was significantly higher than that of dorsal flexors (12.9±2.7 ms versus 8.8±1.2 ms), whereas the 10–50% rise time was longer in plantar (14.9±0.6 ms) than in dorsal (11.8±2.0 ms) flexors.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received after revision: 29 October 1999

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gorselink, M., Drost, M., de Louw, J. et al. Accurate assessment of in situ isometric contractile properties of hindlimb plantar and dorsal flexor muscle complex of intact mice. Pflügers Arch – Eur J Physiol 439, 665–670 (2000). https://doi.org/10.1007/s004249900208

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004249900208

Navigation