Skip to main content
Log in

ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery—the ENERCON systematic review and network meta-analysis

  • Systematic Reviews and Meta-analyses
  • Published:
Langenbeck's Archives of Surgery Aims and scope Submit manuscript

Abstract

Purpose

Energized vessel-sealing systems have been proposed to save operation time and reduce post-operative complications. The aim of the present systematic review was to compare operation time and postoperative morbidity for ultrasonic and electrothermal bipolar-activated devices with conventional hemostasis techniques and with each other in open thyroidectomy.

Methods

A systematic literature search (MEDLINE, Cochrane Library, EMBASE and ISI Web of Science) was performed to identify randomised controlled trials (RCTs) comparing conventional hemostasis techniques, ultrasonic devices (Harmonic® scalpel) and/or electrothermal bipolar-activated vessel sealing systems (Ligasure®) during open thyroidectomy. For the primary endpoint (operation time), a network meta-analysis with Bayesian random effects model was performed. Pairwise meta-analyses with random effects were calculated for primary and secondary endpoints.

Results

One hundred sixteen publications were evaluated for eligibility; 35 RCTs (4,061 patients) were included. There was considerable methodological and clinical heterogeneity of included trials. The Harmonic scalpel significantly reduced operation time compared with conventional techniques (22.26 min, 22.7 min in the inconsistency model). The use of Ligasure significantly reduced operation time in total thyroidectomy (13.84 min in the consistency model, 12.18 min in the inconsistency model). In direct comparison, operations with the Harmonic scalpel were faster than with Ligasure (8.42 min in the consistency model, 2.45 min in the inconsistency model). The rates of recurrent nerve palsy and postoperative hypocalcaemia did not significantly differ in the intervention groups.

Conclusions

This meta-analysis shows superiority of ultrasonic devices in terms of operation time compared with conventional hemostasis techniques in thyroid surgery, with no detriment to safety outcomes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. Bhattacharyya N, Fried MP (2002) Assessment of the morbidity and complications of total thyroidectomy. Arch Otolaryngol Head Neck Surg 128(4):389–392

    Article  PubMed  Google Scholar 

  2. Chiang FY, Lee KW, Huang YF, Wang LF, Kuo WR (2004) Risk of vocal palsy after thyroidectomy with identification of the recurrent laryngeal nerve. Kaohsiung J Med Sci 20(9):431–436

    Article  PubMed  Google Scholar 

  3. Lo CY, Kwok KF, Yuen PW (2000) A prospective evaluation of recurrent laryngeal nerve paralysis during thyroidectomy. Arch Surg 135(2):204–207

    Article  PubMed  CAS  Google Scholar 

  4. Dedivitis RA, Pfuetzenreiter EG Jr, Castro MA, Denardin OV (2009) Analysis of safety of short-stay thyroid surgery. Acta Otorhinolaryngol Ital 29(6):326–330

    PubMed  CAS  Google Scholar 

  5. Shindo M, Stern A (2010) Total thyroidectomy with and without selective central compartment dissection: a comparison of complication rates. Arch Otolaryngol Head Neck Surg 136(6):584–587. doi:10.1001/archoto.2010.79

    Article  PubMed  Google Scholar 

  6. Slakey DP (2008) Laparoscopic liver resection using a bipolar vessel-sealing device: LigaSure. HPB (Oxford) 10(4):253–255. doi:10.1080/13651820802166880

    Article  Google Scholar 

  7. Macario A, Dexter F, Sypal J, Cosgriff N, Heniford BT (2008) Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: a meta-analysis. Surg Innov 15(4):284–291. doi:10.1177/1553350608324933

    Article  PubMed  Google Scholar 

  8. Yao HS, Wang Q, Wang WJ, Ruan CP (2009) Prospective clinical trials of thyroidectomy with LigaSure vs conventional vessel ligation: a systematic review and meta-analysis. Arch Surg 144(12):1167–1174. doi:10.1001/archsurg.2009.201

    Article  PubMed  Google Scholar 

  9. Cirocchi R, D’Ajello F, Trastulli S, Santoro A, Di Rocco G, Vendettuoli D, Rondelli F, Giannotti D, Sanguinetti A, Minelli L, Redler A, Basoli A, Avenia N (2010) Meta-analysis of thyroidectomy with ultrasonic dissector versus conventional clamp and tie. World J Surg Oncol 8:112. doi:10.1186/1477-7819-8-112

    Article  PubMed  Google Scholar 

  10. Ecker T, Carvalho AL, Choe JH, Walosek G, Preuss KJ (2010) Hemostasis in thyroid surgery: harmonic scalpel versus other techniques—a meta-analysis. Otolaryngol Head Neck Surg 143(1):17–25. doi:10.1016/j.otohns.2010.03.018

    Article  PubMed  Google Scholar 

  11. Melck AL, Wiseman SM (2010) Harmonic scalpel compared to conventional hemostasis in thyroid surgery: a meta-analysis of randomized clinical trials. Int J Surg Oncol 2010:396079. doi:10.1155/2010/396079

    PubMed  Google Scholar 

  12. Zhang ZJ, Zhang P, Tian JH, Li J, Li L, Tian J, Yang KH (2010) Ultrasonic coagulator for thyroidectomy: a systematic review of randomized controlled trials. Surg Innov 17(1):41–47. doi:10.1177/1553350610362084

    Article  PubMed  CAS  Google Scholar 

  13. Garas G, Okabaysashi K, Ashrafian H, Shetty K, Palazzo F, Tolley NS, Darzi A, Athanasiou T, Zacharakis E (2013) Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies. Thyroid. doi:10.1089/thy.2012.0588

    PubMed  Google Scholar 

  14. Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535. doi:10.1136/bmj.b2535

    Article  PubMed  Google Scholar 

  15. Higgins JPT (2011) Cochrane handbook for systematic reviews of interventions. Cochrane book series, reprinted edn. Wiley-Blackwell, Chichester, UK

  16. Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA (2011) The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ 343:d5928. doi:10.1136/bmj.d5928

    Article  PubMed  Google Scholar 

  17. Cooper NJ, Sutton AJ, Lu G, Khunti K (2006) Mixed comparison of stroke prevention treatments in individuals with nonrheumatic atrial fibrillation. Archives of internal medicine 166(12):1269–1275. doi:10.1001/archinte.166.12.1269

    Article  PubMed  Google Scholar 

  18. Bucher HC, Guyatt GH, Griffith LE, Walter SD (1997) The results of direct and indirect treatment comparisons in meta-analysis of randomized controlled trials. Journal of clinical epidemiology 50(6):683–691

    Article  PubMed  CAS  Google Scholar 

  19. Hozo SP, Djulbegovic B, Hozo I (2005) Estimating the mean and variance from the median, range, and the size of a sample. BMC medical research methodology 5:13. doi:10.1186/1471-2288-5-13

    Article  PubMed  Google Scholar 

  20. Voutilainen PE, Haglund CH (2000) Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 231(3):322–328

    Article  PubMed  CAS  Google Scholar 

  21. Meurisse M, Defechereux T, Maweja S, Degauque C, Vandelaer M, Hamoir E (2000) Evaluation of the Ultracision ultrasonic dissector in thyroid surgery. Prospective randomized study. Ann Chir 125(5):468–472

    Article  PubMed  CAS  Google Scholar 

  22. Defechereux T, Rinken F, Maweja S, Hamoir E, Meurisse M (2003) Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 103(3):274–277

    PubMed  Google Scholar 

  23. Coimbra C, Defechereux T, Meurisse N, Squifflet JP, Meurisse M (2007) [Ultrasonic scalpel in thyroid surgery]. Rev Med Liege 62 Spec No:83–85

  24. Marchesi M, Biffoni M, Cresti R, Mulas MM, Turriziani V, Berni A, Campana FP (2003) Ultrasonic scalpel in thyroid surgery. Chirurgia italiana 55(2):299–308

    PubMed  Google Scholar 

  25. Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14(1):9–12. doi:10.1089/109264204322862289

    Article  PubMed  Google Scholar 

  26. Cordon C, Fajardo R, Ramirez J, Herrera MF (2005) A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy. Surgery 137(3):337–341. doi:10.1016/j.surg.2004.09.011

    Article  PubMed  Google Scholar 

  27. Frazzetta M, Furgiuele G, Raimondo D, Sammartano A, Mannino E, De Simone G, Vetri G, Bonventre S, Di Gesu G (2005) Ultrasonic dissector for total thyroidectomy: results of prospective randomized study. G Chir 26(8–9):295–301

    PubMed  CAS  Google Scholar 

  28. Miccoli P, Berti P, Dionigi G, D’Agostino J, Orlandini C, Donatini G (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073. doi:10.1001/archotol.132.10.1069

    Article  PubMed  Google Scholar 

  29. Kilic M, Keskek M, Ertan T, Yoldas O, Bilgin A, Koc M (2007) A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy. Adv Ther 24(3):632–638

    Article  PubMed  Google Scholar 

  30. Hallgrimsson P, Loven L, Westerdahl J, Bergenfelz A (2008) Use of the harmonic scalpel versus conventional haemostatic techniques in patients with Grave disease undergoing total thyroidectomy: a prospective randomised controlled trial. Langenbeck’s archives of surgery / Deutsche Gesellschaft fur Chirurgie 393(5):675–680. doi:10.1007/s00423-008-0361-z

    Article  PubMed  CAS  Google Scholar 

  31. Koh YW, Park JH, Lee SW, Choi EC (2008) The harmonic scalpel technique without supplementary ligation in total thyroidectomy with central neck dissection: a prospective randomized study. Ann Surg 247(6):945–949. doi:10.1097/SLA.0b013e31816bcd61

    Article  PubMed  Google Scholar 

  32. Yildirim O, Umit T, Ebru M, Bulent U, Belma K, Betul B, Mete D, Omer C (2008) Ultrasonic harmonic scalpel in total thyroidectomies. Adv Ther 25(3):260–265. doi:10.1007/s12325-008-0024-z

    Article  PubMed  Google Scholar 

  33. Dibidino RRM, Marchetti M, Lombardi N, Raffaelli M, Attina G, Cicchetti A (2010) Harmonic study: a cost-effectiveness evaluation of ultrasonically activated shears for total thyroidectomy. PharmacoEconomics-Italian Research Articles 12(3):143–155

    Article  Google Scholar 

  34. Lombardi CP, Raffaelli M, Cicchetti A, Marchetti M, De Crea C, Di Bidino R, Oragano L, Bellantone R (2008) The use of "harmonic scalpel" versus "knot tying" for conventional "open" thyroidectomy: results of a prospective randomized study. Langenbeck’s Archives of Surgery/Deutsche Gesellschaft fur Chirurgie 393(5):627–631. doi:10.1007/s00423-008-0380-9

    Article  PubMed  Google Scholar 

  35. Witzel K, von Rahden BH, Stein HJ (2009) The effect of ultrasound dissection in thyroid surgery. Eur Surg Res 43(2):241–244. doi:10.1159/000226257

    Article  PubMed  CAS  Google Scholar 

  36. Papavramidis TS, Sapalidis K, Michalopoulos N, Triantafillopoulou K, Gkoutzamanis G, Kesisoglou I, Papavramidis ST (2010) UltraCision harmonic scalpel versus clamp-and-tie total thyroidectomy: a clinical trial. Head & neck 32(6):723–727. doi:10.1002/hed.21240

    Google Scholar 

  37. Miccoli P, Materazzi G, Miccoli M, Frustaci G, Fosso A, Berti P (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199(6):736–740. doi:10.1016/j.amjsurg.2009.04.003

    Article  PubMed  Google Scholar 

  38. Mourad M, Rulli F, Robert A, Scholtes JL, De Meyer M, De Pauw L (2011) Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy. Am J Surg 202(2):168–174. doi:10.1016/j.amjsurg.2010.07.047

    Article  PubMed  Google Scholar 

  39. Gentileschi P, D’Ugo S, Iaculli E, Gaspari AL (2011) Harmonic Focus versus "knot tying" during total thyroidectomy: a randomized trial. Updates Surg 63(4):277–281. doi:10.1007/s13304-011-0099-y

    Article  PubMed  Google Scholar 

  40. He Q, Zhuang D, Zheng L, Zhou P, Chai J, Lv Z (2011) Harmonic focus in total thyroidectomy plus level III-IV and VI dissection: a prospective randomized study. World J Surg Oncol 9:141. doi:10.1186/1477-7819-9-141

    Article  PubMed  Google Scholar 

  41. Ferri E, Armato E, Spinato G, Spinato R (2011) Focus harmonic scalpel compared to conventional haemostasis in open total thyroidectomy: a prospective randomized trial. Int J Otolaryngol 2011:357195. doi:10.1155/2011/357195

    PubMed  Google Scholar 

  42. Kowalski LP, Sanabria A, Vartanian JG, Lima RA, de Mendonca UB, dos Santos CR, Boldrini D Jr, de Mello LE, Pinto FP, Lehn CN, Correa LA, Dedivitis RA, Guimaraes AV, Pedruzzi PA, Ramos GH, Goncalves AJ, Suehara AB, Kanda JL, Capuzzo Rde C, de Oliveira JC, Curado MP, de Gois Filho JF, Fukuyama E, Beserra IM Jr, de Carvalho Neto PB, Carvalho AL (2012) Total thyroidectomy with ultrasonic scalpel: a multicenter, randomized controlled trial. Head & neck 34(6):805–812. doi:10.1002/hed.21815

    Article  Google Scholar 

  43. Docimo G, Ruggiero R, Gubitosi A, Casalino G, Bosco A, Gili S, Conzo G, Docimo L (2012) Ultrasound scalpel in thyroidectomy. Prospective randomized study, Ann Ital Chir

    Google Scholar 

  44. Sista F, Schietroma M, Ruscitti C, De Santis G, De Vita F, Carlei F, Amicucci G (2012) New ultrasonic dissector versus conventional hemostasis in thyroid surgery: a randomized prospective study. J Laparoendosc Adv Surg Tech A 22(3):220–224. doi:10.1089/lap.2011.0266

    Article  PubMed  Google Scholar 

  45. Manouras A, Lagoudianakis EE, Antonakis PT, Filippakis GM, Markogiannakis H, Kekis PB (2005) Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy. Head & neck 27(11):959–962. doi:10.1002/hed.20271

    Article  Google Scholar 

  46. Goretzki PE, Pohl P, Terorde N, Krause-Paulus RM, Lammers BJ (2005) [New methods in thyroid surgery—the ligation free preparation and dissection with LigaSure]. Viszeralchirurgie (3):214–218

  47. Goretzki PE, Schwarz K, Lammers BJ (2009) Implementing the general use of dissection devices in thyroid surgery from prospective randomized trial to daily use. Surg Technol Int 18:86–92

    PubMed  Google Scholar 

  48. Saint Marc O, Cogliandolo A, Piquard A, Fama F, Pidoto RR (2007) LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study. Arch Surg 142(2):150–156. doi:10.1001/archsurg.142.2.150, discussion 157

    Article  PubMed  Google Scholar 

  49. Marrazzo A, Casa L, David M, Lo Gerfo D, Noto A, Riili I, Taormina P (2007) Thyroidectomy with LigaSure versus traditional thyroidectomy: our experience. Chirurgia italiana 59(3):361–365

    PubMed  Google Scholar 

  50. Minner S, Rodiger H, Mansmann U, Bohm B (2007) Randomized controlled trial on vessel sealing in thyroid surgery. Zentralbl Chir 132(5):446–450. doi:10.1055/s-2007-981279

    Article  PubMed  CAS  Google Scholar 

  51. Singh P, O’Connell D, Langille M, Dziegielewski P, Allegretto M, Harris J (2010) LigaSure versus conventional hemostasis in thyroid surgery: prospective randomized controlled trial. J Otolaryngol Head Neck Surg 39(4):378–384

    PubMed  Google Scholar 

  52. Schiphorst AH, Twigt BA, Elias SG, van Dalen T (2012) Randomized clinical trial of LigaSure versus conventional suture ligation in thyroid surgery. Head Neck Oncol 4:2. doi:10.1186/1758-3284-4-2

    Article  PubMed  Google Scholar 

  53. Sartori PV, De Fina S, Colombo G, Pugliese F, Romano F, Cesana G, Uggeri F (2008) Ligasure versus Ultracision in thyroid surgery: a prospective randomized study. Langenbeck’s archives of surgery / Deutsche Gesellschaft fur Chirurgie 393(5):655–658. doi:10.1007/s00423-008-0386-3

    Article  PubMed  Google Scholar 

  54. Pons Y, Gauthier J, Ukkola-Pons E, Clement P, Roguet E, Poncet JL, Conessa C (2009) Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy. Otolaryngol Head Neck Surg 141(4):496–501. doi:10.1016/j.otohns.2009.06.745

    Article  PubMed  Google Scholar 

  55. Di Renzo RM, Bove A, Bongarzoni G, Palone G, Corradetti L, Corbellini L (2010) Comparison of conventional technique, Ligasure Precise and Harmonic Focus in total thyroidectomy. G Chir 31(6–7):296–298

    Google Scholar 

  56. Rahbari R, Mathur A, Kitano M, Guerrero M, Shen WT, Duh QY, Clark OH, Kebebew E (2011) Prospective randomized trial of ligasure versus harmonic hemostasis technique in thyroidectomy. Ann Surg Oncol 18(4):1023–1027. doi:10.1245/s10434-010-1251-5

    Article  PubMed  Google Scholar 

  57. Dionigi G, Boni L, Rausei S, Frattini F, Ferrari CC, Mangano A, Leotta A, Franchin M (2012) The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure (LF1212) and the Harmonic(R) FOCUS. Langenbeck’s Archives of Surgery/Deutsche Gesellschaft fur Chirurgie 397(5):817–823. doi:10.1007/s00423-011-0898-0

    Article  PubMed  Google Scholar 

  58. Dionigi G, Van Slycke S, Rausei S, Boni L, Dionigi R (2012) Parathyroid function after open thyroidectomy: a prospective randomized study for ligasure precise versus harmonic FOCUS. Head & neck. doi:10.1002/hed.23005

    Google Scholar 

  59. Dias S WN, Sutton AJ, Ades AE (2011) NICE DSU Technical Support Document 2: a generalised linear modelling framework for pairwise and network meta-analysis of randomised controlled trials. National Institute for Health and Clinical Excellence (NICE) http://www.nicedsu.org.uk. Accessed March 2013

  60. Dias S WN, Sutton AJ, Caldwell DM, Lu G, Ades AE (2011) NICE DSU Technical Support Document 4: inconsistency in networks of evidence based on randomised controlled trials. National Institute for Health and Clinical Excellence (NICE) http://www.nicedsu.org.uk. Accessed March 2013

  61. Mehanna HM, Jain A, Randeva H, Watkinson J, Shaha A (2010) Postoperative hypocalcemia—the difference a definition makes. Head & neck 32(3):279–283. doi:10.1002/hed.21175

    Google Scholar 

  62. Dionigi G (2009) Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments. Langenbeck’s Archives of Surgery/Deutsche Gesellschaft fur Chirurgie 394 (3):579–580; author reply 581–576. doi:10.1007/s00423-008-0454-8

  63. Karvounaris DC, Antonopoulos V, Psarras K, Sakadamis A (2006) Efficacy and safety of ultrasonically activated shears in thyroid surgery. Head & neck 28(11):1028–1031. doi:10.1002/hed.20445

    Article  Google Scholar 

  64. Barczynski M, Konturek A, Cichon S (2008) Minimally invasive video-assisted thyreoidectomy (MIVAT) with and without use of harmonic scalpel—a randomized study. Langenbeck’s Archives of Surgery/Deutsche Gesellschaft fur Chirurgie 393(5):647–654. doi:10.1007/s00423-008-0373-8

    Article  PubMed  Google Scholar 

  65. Scerrino G, Paladino NC, Di Paola V, Morfino G, Matranga D, Gulotta G, Bonventre S (2010) Total thyroidectomy performed with the Starion vessel sealing system versus the conventional technique: a prospective randomized trial. Surg Innov 17(3):242–247. doi:10.1177/1553350610376394

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

None

Conflicts of interest

None

Sources of funding

None

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Markus K. Diener.

Additional information

Authors’ contributions

Pietro Contin: Literature search, Data extraction, Risk of bias assessment, Manuscript draft

Käthe Gooßen: Updated literature search, Duplicate data extraction, Risk of bias assessment, Reviewed statistical analysis, Reviewed manuscript

Kathrin Grummich: Updated literature search, Duplicate data extraction, Risk of bias assessment

Katrin Jensen: planned, performed and interpreted the statistical analysis

Hubertus Schmitz-Winnenthal: Helped to draft the manuscript

Markus W. Büchler: Helped to draft the manuscript

Markus K. Diener: Helped to draft the manuscript and helped in the analysis and interpretation of data

PC carried out the search, extracted the data, assisted in the risk of bias assessment and drafted the manuscript. KGo and KGr updated the search, performed the duplicate data extraction and assessed the risk of bias. KGo updated and critically reviewed the statistical analysis and manuscript draft. KJ planned, performed and interpreted the statistical analysis. MD helped to draft the manuscript and helped in the analysis and interpretation of data. HSW and MWB helped to draft the manuscript. All authors read and approved the final manuscript.

Electronic supplementary material

Below is the link to the electronic supplementary material.

ESM 1

(JPEG 191 kb)

High-resolution image (TIFF 8313 kb)

ESM 2

(JPEG 16 kb)

High-resolution image (TIFF 2215 kb)

ESM 3

(JPEG 14 kb)

High-resolution image (TIFF 3015 kb)

ESM 4

(JPEG 15 kb)

High-resolution image (TIFF 1349 kb)

ESM 5

(PDF 98 kb)

Rights and permissions

Reprints and permissions

About this article

Cite this article

Contin, P., Gooßen, K., Grummich, K. et al. ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery—the ENERCON systematic review and network meta-analysis. Langenbecks Arch Surg 398, 1039–1056 (2013). https://doi.org/10.1007/s00423-013-1137-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00423-013-1137-7

Keywords

Navigation