Abstract
Endoscope holders are utilized by a variety of surgeons but are not commonplace in head and neck surgery. The SOLOASSIST active camera holder, which is currently used for abdominal surgery, will soon be adapted for head and neck surgery in collaboration with AKTORmed GmbH SOLO SURGERY (Barbing, Germany). In our pre-feasibility study, we analyzed the use of the existing endoscope holder on anatomical specimens during head and neck surgery. Based on these results, we are proceeding towards the development of a new endoscope holder for head and neck surgery. First, we drafted the technical concepts and discussed the advantages and disadvantages of the system. Then, we used anatomic specimens to measure the forces that occur intraoperatively during sinus surgery. Next, we designed a computer-aided design (CAD) model. Finally, we developed the first production prototype and used it for a frontal skull base procedure on an anatomical specimen. We present the three most promising concepts for a new holder. The resulting total force (F res = √(X 2 + Y 2 + Z 2)) was calculated to be 3.2 N during sinus surgery. We could observe all necessary intraoperative landmarks with the endoscope and its holder in a sinus and frontal skull base surgery. We developed a production prototype of a new endoscope holder and demonstrate satisfactory results in the use of anatomic specimens for skull base surgery.
Similar content being viewed by others
References
Gillen S, Pletzer B, Heiligensetzer A, Wolf P, Kleef J, Feussner H, Fürst A (2013) Solo-surgical laparoscopic cholecystectomy with a joystick-guided camera device: a case-control study. Surg Endoscop. doi:10.1007/s00464-013-3142-x
Federspil PA (2007) Automatic guided endoscopy in nasal sinus surgery. HNO 55(3):164–165
Federspil PA, Geisthoff UW, Henrich D, Plinkert PK (2003) Development of the first force-controlled robot for otoneurosurgery. Laryngoscope 113:465–470
Strauß G, Winkler D, Jacobs S et al (2005) Mechatronic in functional endoscopic sinus surgery. First experiences with the da Vinci Telemanipulatory System. HNO 53(7):623–630
Strauß G, Hofer M, Kehrt S et al (2007) Manipulator assisted endoscope guidance in functional endoscopic sinus surgery: proof of concept. HNO 55(3):177–184
Wurm J, Bumm K, Steinhart H et al (2005) Development of an active robot system for multimodal paranasal sinus surgery. HNO 53(5):446–454
Weinstein GS, Quon H, Newman HJ et al (2012) Transoral robotic surgery alone for oropharyngeal cancer: an analysis of local control. Arch otolaryngol Head Neck Surg 138(7):628–634
Kayhan FT, Kaya KH, Sayin I (2012) Transoral robotic cordectomy for early glottic carcinoma. Ann Otol Rhinol Laryngol 121(8):497–502
Smith RV, Schiff BA, Sarta C, Hans S, Brasnu D (2013) Transoral robotic total laryngectomy. Laryngoscope 123(3):678–682
Park YM, Kim WS, Byeon HK, De Virgilio A, Jung JS, Kim SH (2010) Feasibility of transoral robotic hypopharyngectomy for early-stage hypopharyngeal carcinoma. Oral Oncol 46(8):587–602
Hanna EY, Holsinger C, de Monte F, Kupferman M (2007) Robotic endoscopic surgery oft he skull base: a novel surgical approach. Arch Otolaryngol Head Neck Surg 133(12):1209–1214
Yin Tsang RK, Ho WK, Wei WI (2012) Combined transnasal endoscopic and transoral robotic resection of nasopharyngeal carcinoma. Head Neck 34(8):1190–1193
Carrau RL, Prvedello DM, de Lara D, Durmus K, Ozer E (2013) Combined transoral robotic surgery and endoscopic endonasal approach for the resection of extensive malignancies of the skull base. Head Neck 35(11):E351–E358
Nathan CO, Chakradeo V, Nalhotra K, D’Agostino H, Patwardhan R (2006) The voice-controlled robotic assist scope holder AESOP for the endoscopic approach to the sella. Skull Base 16(3):123–131
Fischer M, Gröbner C, Lueth TC, Strauß G (2012) First clinical experiences with an endoscope manipulator system in endo- and transnasal surgery. Laryngorhinootolgie 91(8):487–493
Eskandari R, Amini A, Yonemura KS, Couldwell WT (2008) The use oft he Olympus EndoArm for spinal and skull-based transsphenoidal neurosurgery. Minim Invas Neurosurg 51(6):370–372
Kolmer A, Monkman G. Bachelorthesis (2013) Vorentwicklung eines automatischen Endoskophaltesystems für den Einsatz im Bereich der HNO-Medizin. Faculty of electrical engineering, Regensburg, Germany
Kristin J, Geiger R, Knapp FB, Schipper J, Klenzner T (2011) Use of a mechatronic robotic camera holding system in head and neck surgery. HNO 59(6):575–581
Eichhorn KWG, Tingelhoff K, Wagner I et al (2008) Evauation of force data with a force/torque sensor during FESS. A step towards robot-assisted surgery. HNO 56(8):789–794
Wagner I, Tingelhoff K, Westphal R et al (2008) Ex vivo evaluation of force data and tissue elasticity for robot-assisted FESS. Eur Arch Otorhinolaryngol 265:1335–1339
Eskandari R, Amini A, Yonemura KS, Couldwell WT (2008) The use of the Olympus EndoArm for spinal and skull-based transsphenoidal Neurosurgery. Minim Invas Neurosurg 51:370–372
Acknowledgments
Dr. Julia Kristin has full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis. The project is funded by the German Federal Ministry for Economics and Labour. Central Innovation Program SME- Germany.
Conflict of interest
The project is a collaboration with the company AKTORmed GmbH, Germany. There is no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kristin, J., Kolmer, A., Kraus, P. et al. Development of a new endoscope holder for head and neck surgery—from the technical design concept to implementation. Eur Arch Otorhinolaryngol 272, 1239–1244 (2015). https://doi.org/10.1007/s00405-014-3052-0
Received:
Accepted:
Published: