Introduction

In spite of the recent progress in noninvasive visualization of coronary artery trees using multidetector computed tomography and magnetic resonance imaging (MRI) [14], myocardial perfusion imaging is remaining as an important part of the assessment of patients with ischaemic heart disease. Myocardial perfusion is evaluated by single photon emission computed tomography in most patients today; however, this technique exposes patients to radiation and its diagnostic accuracy is sometimes limited by relatively low spatial resolution and artifacts from photon scatter and tissue attenuation.

First-pass contrast–enhanced MRI of the myocardium has emerged as a noninvasive method that can allow accurate assessment of myocardial ischaemia caused by flow-limiting stenosis without radiation [58]. Sensitivities of 81–93% and specificities of 68–90% have been reported for stress first-pass perfusion MRI in the detection of clinically significant coronary artery disease (CAD) as defined at coronary angiography [917]. However, to the best of out knowledge, there are only three multicenter studies demonstrating the diagnostic performance of first-pass perfusion MRI for the detection of CAD [1214]. Moreover, none of the three studies included late gadolinium-enhanced (LGE) MRI in the analysis. The purpose of this multicenter study was to prospectively determine the diagnostic accuracy of stress-rest perfusion MRI and LGE MRI in detecting flow-limiting obstructive CAD using conventional coronary angiography as a reference standard.

Materials and methods

Patients

This prospective multicenter trial was performed at three clinical sites, with ethics committee approval in each site. Written informed consent was obtained from all patients. A total of 50 patients with known or suspected CAD who met the following inclusion and exclusion criteria were enrolled. The number of patients from each clinical site enrolled was 29, 10, and 11, respectively. The study group included 36 men and 14 women aged 41–83 years (mean age 65.4 ± 9.4). Patient demographics were summarized in Table 1. Patients were included in the study if (1) they were scheduled for cardiac catheterization with suspect of current obstructive coronary artery stenosis based on clinical symptom and/or positive stress test and (2) there was no contraindication to contrast-enhanced MRI. Patients were excluded if they were medically unstable, had contraindications for adenosine triphosphate (ATP) stress (i.e., second- or third-degree A-V block, sick sinus syndrome, known hypersensitivity to ATP). Patients with clinical myocardial infarction by history or medical record and those who had previously undergone coronary artery bypass graft surgery were excluded.

Table 1 Patient demographics (PCI percutaneous coronary intervention)

MRI protocol

MRI was performed using 1.5-T systems of the same manufacturer. Three institutions had a different model (CV/i, Twinspeed, Echospeed, GE Medical Systems, Milwaukee, Wis., USA), but all of them had similar imaging capability with the same software version and pulse sequences. Systems were equipped with gradient strength of 33–40 mT/m; slew rate of 120–150 T/m/s and a four-element phased-array coil. Patients were advised to withdraw caffeine intake for 24 h prior to the test. A 20-gauge catheter was inserted into an antecubital vein for contrast agent injection and a 22-gauge catheter into an antecubital vein of the other arm for pharmacologic stress agent administration.

First-pass contrast-enhanced MR images were obtained during pharmacologic stress and in the resting state with an ECG-gated saturation-recovery steady-state free precession (SSFP) perfusion sequence [18]. The sequence consisted of a non-section-selective 90° saturation pulse and a single-shot SSFP image acquisition with sequential k-space sampling. The following parameter settings were used in all institutions: 3.0/1.2/250 [repetition time (ms)/echo time (ms)/inversion time (ms)]; inversion time represents time between saturation pulse to the center of acquisition window); flip angle 45°; band width of 64 kHz; 340–380 mm field of view; 128 × 96 matrix; 8-mm thick sections; a phase FOV factor of 0.75; and a voxel size of 72 mm3 (3 mm × 3 mm × 8 mm). Four to six short-axis images of the left ventricle were obtained for every other heartbeat for approximately 1 min. For hyperemic perfusion imaging, contrast injection and image acquisition began 3 min after the initiation of ATP infusion (140 µg/kg/min) [19, 20]. Patients were monitored for possible adverse event caused by ATP infusion, such as persistent or symptomatic AV block, severe hypotension and dyspnea. As soon as dynamic image acquisition started, 0.05 mmol/kg gadopentetate dimeglumine (Magnevist; Schering, Berlin, Germany) was injected into the antecubital vein with an MRI-compatible power injector at a rate of 4 ml/s, followed by a 20-ml saline flush. The ATP infusion was then stopped 4 min after it was initiated. Approximately 15 min after the cessation of ATP infusion, resting (non-hyperemic) first-pass perfusion MR images were acquired with the same imaging parameters and dose of contrast agent. During the first-pass imaging, patients were requested to hold their breath as long as they could, then make shallow breathing thereafter so that respiratory artifacts are minimized. Cardiac functional MRI using cine SSFP sequence was also performed between stress and rest perfusion MRI, but was not evaluated in this study.

Subsequently, 0.05 mmol gadopentetate dimeglumine per kilogram of body weight was administered in order to obtain cumulative dose of 0.15 mmol/kg, which was optimized for late gadolinium-enhancement imaging. After 10 min, late enhancement images were acquired in short-axis sections by using an ECG-gated inversion-recovery prepared two-dimensional (2D) fast gradient-echo MR sequence in order to detect possible subclinical scars that otherwise remain unrecognized. Parameters for inversion-recovery gradient-echo sequences were as follows: 5.3/1.3/230–270 [repetition time(ms)/echo time (ms)/inversion time (ms)]; flip angle, 25°; field of view, 340–380 mm; matrix, 256 × 128; and section thickness, 5 mm. The inversion time was adjusted to minimize the signal from normal myocardium by acquiring several test images with different inversion times.

MRI analysis

All patient studies were collected and anonymized. Two radiologists independently reviewed all the image datasets without knowing patient history, including age and sex, other imaging and laboratory study results. Prestudy experience of observer 1 and 2 in cardiovascular MRI was equivalent to level 3 (>300 cases, 1 year) and 2 (>150 cases, 3 months), respectively, based on the guideline compiled by the Society the American College of Cardiology Task Force [21]. Stress and rest perfusion images were displayed side by side and visually evaluated by manually paging the images. In addition, LGE images were presented to assess the presence of myocardial scar. The observers recorded the presence or absence of stress-induced hypoperfusion using the AHA 16-segment model with a scale of 1–5: 1 = definitely normal, 2 = probably normal, 3 = possibly abnormal, 4 = probably abnormal, and 5 = definitely abnormal. The most apical segment in the AHA 17-segment model was excluded from the analysis, since evaluation of apex was impossible on the short axis images. Analysis of the LGE MRI was also performed based on the 16-segment model and the same five-point scale used for perfusion MRI analysis.

Before reviewing cases for this study, these observers completed a training session together, which consisted of a review of ten MR studies including stress-rest perfusion and LGE and their coronary catheterization results. These cases were not included in the current patient population. Through the training session, they shared the following interpretation criteria. Stress-induced hypoperfusion was considered present if a focal region of myocardium showing diminished contrast enhancement was present during stress that was not observed at rest. If similar hypointensity was observed both during stress and at rest, it was considered to be an artifact or scar, and absence of stress-induced hypoperfusion was recorded. Therefore, LGE without perfusion abnormality was interpreted as negative for myocardial ischaemia. If hypointensity area during stress was larger than that at rest, it was interpreted as stress-induced ischemia with partial artifact or scar, and presence of stress-induced hypoperfusion was recorded. The observers also agreed on how to differentiate true perfusion defect from subendocardial artifact. The differentiation was performed on the basis of their signal intensities, duration and distribution. Typically, signal intensities of artifacts are lower than that of the same region before contrast injection and appear at the time of contrast agent inflow into the left ventricle lasting only for a few images in the perfusion series [2224]. In regard to distribution, circular hypointensity regions throughout the subendocardium of the left ventricle were considered to be more suggestive of artifact, whereas perfusion defects characterized by subendocardial predominance and segmental distribution of coronary artery were considered to be indicative of true perfusion defect.

Conventional coronary angiography

Conventional X-ray coronary angiography was considered as the reference standard for the evaluation of coronary artery stenosis. Conventional coronary angiography was performed within 14 days of the contrast-enhanced MR study at the same center that MR study was performed. Images were then transferred to one of the three centers and analysed by an observer with 20 years of experience in coronary angiography. The observer was blinded to both clinical as well as MR images and evaluated all epicardial coronary artery segments with diameter of 2 mm or greater including branches by using a workstation (Advantage CRS and QCA package; GE Medical Systems). The presence or absence of luminal diameter reduction of 50% or greater on coronary angiography was recorded in the three major coronary arteries. In order to correlate the coronary artery distribution on coronary angiography with myocardial perfusion abnormality on MRI, the AHA classification cross-sectional myocardial segments used for MRI analysis were assigned to three major coronary artery territories (left anterior descending artery, circumflex artery, and right coronary artery) based on the coronary artery distribution demonstrated by coronary angiography.

Statistical analysis

Statistical analyses were performed with a commercially available statistical analysis package, SPSS 11.5 J (SPSS, Chicago, Ill., USA). Continuous variables are expressed as mean ± SD. The efficacy of the contrast-enhanced MR study for each reader was evaluated using receiver-operating characteristic curve (ROC) analyses based on the five-point scale visual assessment. Sensitivity, specificity, positive and negative predictive values, and accuracy with the corresponding 95% confidence interval (CI) were calculated using binary assessment as positive (score ≥3) versus negative (score <3). Cohen’s κ statistic was used to assess for interobserver agreement on the binary assessments. Combined assessment of first-pass perfusion MRI and LGE MRI was performed based on the higher score of the two modalities.

Results

Quantitative coronary angiography

The prevalence of obstructive CAD defined on lesions >50% stenosis was 72% (36/50 patients). Twelve patients had single-vessel disease, 16 patients had double-vessel disease, and eight patients had triple-vessel disease.

Stress-rest perfusion MRI for detecting obstructive CAD

First-pass contrast-enhanced MR images were of adequate quality for image interpretation in all patients (Fig. 1). No serious adverse event was reported during ATP stress. Subendocardial dark rim artifact was observed in 40 (80%) patients on at least one short-axis slice of stress-rest perfusion MRI. These artifacts were differentiated from true perfusion defect based on their characteristic signal behavior and distribution, as discussed above. The sensitivity of stress-rest first-pass perfusion MRI in the identification of patients with flow-limiting stenosis of at least one coronary artery was 89% (32/36; 95% CI 76, 96) and 83% (30/36; 95% CI 69, 93) by observer 1 and 2, respectively. The specificity of MRI in detecting patients with flow-limiting stenosis in the coronary artery was 79% (11/14; 95% CI 53, 94) by observer 1 and 71% (10/14; 95% CI 46, 90) by observer 2 (Table 2). Cohen’s κ statistic showed a moderate interobserver agreement (κ = 0.49). The area under the ROC curve (AUC) in this patient-based analysis was 0.92 (95% CI 0.83, 0.99) for observer 1 and 0.84 (95% CI 0.73, 0.96) for observer 2 (Fig. 2). Sensitivities by observer 1 and 2 were 83% (10/12; 95% CI 56, 96) and 75% (9/12; 95% CI 47, 92), 88% (14/16; 95% CI 66, 97) and 81% (13/16; 95% CI 58, 94), and 100% (8/8; 95% CI 74, 100) and 100% (8/8; 95% CI 74, 100), respectively, for the detection of single-, double-, and triple-vessel disease.

Fig. 1a–d
figure 1

Comparison between MRI and conventional coronary angiography in a 65-year-old patient. a, b Short-axis perfusion MR series acquired with a saturation-recovery SSFP sequence (3.0/1.2; field of view, 340 mm; matrix, 128 × 96; flip angle, 45°) (a) during ATP stress and (b) at rest. Images of the same slice were shown to demonstrate contrast wash-in and wash-out. Perfusion deficits (arrows) were observed in the anterolateral wall and inferior wall of the left ventricle during stress. c Short-axis LGE MR images of the patient acquired with an inversion-recovery spoiled gradient echo sequence (5.3/1.3; field of view, 340 mm; matrix, 256 × 128, flip angle, 25°). Two focal hyperenhancements were observed in the anterior wall and inferolateral wall. Note the much smaller size of the late hyperenhancement compared to perfusion deficit on stress first-pass perfusion MR images. d Right anterior oblique conventional angiogram demonstrated multiple highgrade stenoses in the diagonal branch of the left anterior descending artery and left circumflex artery (arrows). e Left anterior oblique conventional angiogram displayed right coronary artery with a high grade stenosis (arrow)

Fig. 2
figure 2

ROC curves of stress-rest perfusion MRI for predicting patients with flow-limiting coronary artery disease. The AUC was 0.92 for observer 1 and 0.84 for observer 2

Table 2 Diagnostic performance of stress-rest perfusion MRI for detecting patients with flow-limiting coronary artery stenosis

The sensitivity and specificity of stress first-pass contrast-enhanced MRI for predicting flow-limiting stenosis in the individual coronary artery were 81% (55/68; 95% CI 70, 89) and 83% (68/82; 95% CI 74, 90) by observer 1, 72% (49/68; 95% CI 61, 82) and 87% (71/82; 95% CI 78, 93) by observer 2 with a substantial interobserver agreement (κ = 0.61) (Table 3). The area under the ROC curve in this vessel-based analysis was 0.83 (95% CI 0.77, 0.90) for observer 1 and 0.82 (95% CI 0.74, 0.89) for observer 2 (Fig. 3).

Fig. 3
figure 3

ROC curves of stress-rest perfusion MRI for detecting flow-limiting stenosis in the individual coronary artery. The AUC was 0.83 for observer 1 and 0.82 for observer 2

Table 3 Diagnostic performance of stress-rest perfusion MRI for detecting flow-limiting stenosis in individual coronary arteries

LGE MRI for detecting obstructive CAD

Small focal areas of LGE were observed in 24 (48%) and 26 (52%) of the 50 patients by observer 1 and 2, respectively, in spite of the exclusion of patients with clinical myocardial infarction from the study population. When presence of LGE was used for predicting flow-limiting coronary artery stenosis irrespective of perfusion MRI findings, its sensitivity and specificity for detecting patients with obstructive CAD was 56% (20/36; 95% CI 39, 71) and 71% (10/14; 95% CI 46, 90) by observer 1, and 61% (22/36; 95% CI 45, 76) and 71% (10/14; 95% CI 46, 90) by observer 2, respectively, with a substantial interobserver agreement (κ = 0.68). The AUC was 0.64 (95% CI 0.46, 0.81) for observer 1 and 0.67 (95% CI 0.51, 0.84) for observer 2 in the patient based analysis. At the vessel level analysis, sensitivity and specificity of LGE MRI was 32% (22/68; 95% CI 22, 44) and 93% (76/82; 95% CI 86, 97) by observer 1, and 35% (24/68; 95% CI 25, 47) and 93% (76/82; 95% CI 86, 97) by observer 2, with a substantial interobserver agreement (κ = 0.74). The ROC curve analysis at the vessel level showed an AUC of 0.62 (95% CI 0.53, 0.72) and 0.64 (95% CI 0.55, 0.73) for observer 1 and 2, respectively.

Combination of stress-rest perfusion MRI and LGE MRI yielded sensitivity and specificity of 92% (33/36; 95% CI 79, 98) and 57% (8/14; 95% CI 32, 80) by observer 1, 92% (33/36; 95% CI 79, 98) and 50% (7/14; 95% CI 26, 74) by observer 2, respectively, for identifying patients with obstructive CAD with a substantial interobserver agreement (κ = 0.70) (Table 4). Area under the ROC curve was 0.81 (95% CI 0.66, 0.96) and 0.80 (95% CI 0.64, 0.95) for observer 1 and 2, respectively (Fig. 4). At the vessel level analysis, its sensitivity and specificity was 82% (56/68; 95% CI 72, 90) and 78% (64/82; 95% CI 68, 86) by observer 1, 75% (51/68; 95% CI 64, 84) and 79% (65/82; 95% CI 70, 87) by observer 2, respectively, with a substantial interobserver agreement (κ = 0.65) (Table 5). Area under the ROC curve for vessel level analysis was 0.82 (95% CI 0.75, 0.89) and 0.80 (95% CI 0.73, 0.88) for observer 1 and 2, respectively (Fig. 5).

Fig. 4
figure 4

ROC curves of combination of stress-rest perfusion MRI and LGE MRI for predicting patients with flow-limiting coronary artery disease. The AUC was 0.81 for observer 1 and 0.80 for observer 2

Fig. 5
figure 5

ROC curves of combination of stress-rest perfusion MRI and LGE MRI for detecting flow-limiting stenosis in the individual coronary artery. The AUC was 0.82 for observer 1 and 0.80 for observer 2

Table 4 Diagnostic performance of combination of stress-rest perfusion MRI and LGE MRI for detecting patients with flow-limiting coronary artery stenosis
Table 5 Diagnostic performance stress-rest perfusion MRI and LGE MRI for detecting flow-limiting stenosis in individual coronary arteries

Discussion

This study demonstrates (1) that stress-rest first-pass perfusion MRI using SSFP technique and ATP is an accurate diagnostic test for the detection of flow-limiting CAD, and (2) combining presence of scar on LGE MRI can improve sensitivity and interobserver agreement, but does not improve the overall diagnostic performance of MRI study when luminal narrowing on coronary angiography is used as a reference method.

Diagnostic performance of stress-rest perfusion MRI

Recent studies showed that first-pass contrast-enhanced MRI with vasodilator stress allows for the accurate detection of hemodynamically significant coronary artery stenosis [913, 15, 16]. However, to our knowledge, only three multicenter studies are available. Giang et al. [13] monitored wash-in kinetics of contrast medium using a hybrid echo-planar pulse sequence in 94 patients (up to 27 patients per subgroup receiving the same contrast dose) at three clinical centers. By assessing the upslope of the time-intensity curve, single hyperemic perfusion MRI showed a sensitivity of 93% and specificity of 75%. Wolff et al. [12] obtained first-pass contrast-enhanced MR images in 99 patients (up to 26 patients per subgroup receiving the same contrast dose) at three clinical sites by using a segmented echo-planar imaging pulse sequence with a notched saturation pulse. By visual assessment of stress and rest perfusion MRI, the sensitivity and specificity of first-pass contrast-enhanced MRI in detecting patients with significant coronary stenosis were 93% and 75%, respectively. The largest multicenter perfusion MRI study published so far is MR-IMPACT, which included 234 patients (up to 50 patients per subgroup receiving the same contrast dose) from 18 centeres [14]. By visual assessment, diagnostic performance of perfusion MRI in 42 patients who received optimal contrast dose showed similar performance as SPECT (AUC 0.86 for MRI vs 0.75 for SPECT) [14]. In the current study, perfusion MRI yields sensitivities and specificities of 89% and 79% (AUC 0.92) by an observer with CMR training level of 3, and 83% and 71% (AUC 0.84) by an observer with CMR training level of 2 for the detection of patients with obstructive CAD. We employed saturation-recovery SSFP sequence for MR perfusion imaging in this study since this technique has been shown to have better signal-to-noise and contrast-to-noise ratio compared with spoiled gradient-echo and segmented echo-planar techniques [25]. Although SSFP perfusion is considered more susceptible to dark-rim artifacts, use of SSFP sequence resulted in at least no appreciable deterioration in diagnostic performance in our study cohort in comparison with previous reports.

LGE MRI in the detection of obstructive CAD

LGE images obtained with inversion-recovery prepared MR sequence permits the detection of small myocardial scars [26]. In the current study, small areas of late enhancement were observed in about a half of the study population in spite of the exclusion of patients with clinical myocardial infarction. The incidence of LGE in our study is not surprising given the high prevalence of CAD in this population sample. As a matter of fact, a recent population-based study in Sweden showed that 19.8% of randomly selected 70-year-old subjects had subclinical myocardial infarct reflected as focal area of LGE [27].

Several studies have demonstrated that combining LGE MRI with stress-rest perfusion MRI can improve the sensitivity of MRI for obstructive CAD without deteriorating the specificity when only obvious myocardial infarction (i.e., LGE consistent with a coronary distribution) were considered [28, 29]. However, correlating the presence of LGE with flow-limiting obstructive CAD can be inappropriate since microinfarcts may occur without coronary artery narrowing as a result of plaque rupture/ulceration and subsequent washout of the lipid pool with or without additional thrombus formation into the microcirculation [30, 31]. As a result, the scar can be atypical for myocardial infarction. In fact, many of the areas of LGE in our study were small focal lesions rather than those showing typical appearance of myocardial infarction. And inclusion of these small focal LGE seems to be the reason why combination of stress-rest perfusion MRI and LGE MRI resulted in deterioration of specificity in our study. Nevertheless, combined assessment of stress-rest perfusion MRI and LGE MRI seems to be valuable. By adding LGE MRI, the sensitivity was increased to 92% in both of the two observers, reducing the chance of overlooking patients with obstructive CAD. In addition, substantial interobserver agreement was achieved with a combination of perfusion and LGE MRI (κ = 0.70) compared with moderate agreement with perfusion MRI alone (κ = 0.49), indicating that combined assessment can be less subjective and more independent of the observers’ experience. Reduced specificity resulting from the combination of LGE MRI should not be interpreted as reduced diagnostic value because detection of unrecognized myocardial scar is valuable in the management of patients with CAD, since presence of unrecognized scar tissue has incremental prognostic impact beyond clinical, angiographic, and functional predictors [32].

Limitations

There are several limitations in this study. Firstly, the number of the patients is relatively small. Reliable estimation of specificity and negative predictive value at the patient level was not possible due to the relatively small number of patient population and the high prevalence of CAD, and further investigation is required. Secondly, the morphological assessments of CAD by quantitative coronary angiography evaluated by a single observer as the standard of reference for perfusion MRI can be a limitation because myocardial perfusion MRI reflects the physiologic severity of coronary artery stenosis rather than its morphology. Third limitation in this study is that presence and absence of perfusion deficits were determined solely by visual assessment. Quantitative analysis of myocardial perfusion MRI potentially enhances the diagnostic performance of first-pass contrast-enhanced MRI.

Conclusions

This multicenter study demonstrated that stress-rest myocardial perfusion MRI acquired with a SSFP sequence and ATP has high sensitivity, specificity and a moderate interobserver agreement for identifying patients with obstructive CAD. Combination of LGE MRI is of diagnostic value since sensitivity and interobserver agreement of stress-rest perfusion MRI can be improved. Further investigation is required to determine the specificity and negative predictive value of stress-rest perfusion MRI, LGE MRI and combination of the two.