Skip to main content
Log in

Robustness of Treatment Planning for Electrochemotherapy of Deep-Seated Tumors

  • Published:
The Journal of Membrane Biology Aims and scope Submit manuscript

Abstract

Treatment of cutaneous and subcutaneous tumors with electrochemotherapy has become a regular clinical method, while treatment of deep-seated tumors is still at an early stage of development. We present a method for preparing a dedicated patient-specific, computer-optimized treatment plan for electrochemotherapy of deep-seated tumors based on medical images. The treatment plan takes into account the patient’s anatomy, tissue conductivity changes during electroporation and the constraints of the pulse generator. Analysis of the robustness of a treatment plan made with this method shows that the effectiveness of the treatment is not affected significantly by small single errors in electrode positioning. However, when many errors occur simultaneously, the resulting drop in effectiveness is larger, which means that it is necessary to be as accurate as possible in electrode positioning. The largest effect on treatment effectiveness stems from uncertainties in dielectric properties and electroporation thresholds of treated tumors and surrounding tissues, which emphasizes the need for more accurate measurements and more research. The presented methods for treatment planning and robustness analysis allow quantification of the treatment reproducibility and enable the setting of suitable safety margins to improve the likelihood of successful treatment of deep-seated tumors by electrochemotherapy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  • Bortfeld T (1999) Optimized planning using physical objectives and constraints. Semin Radiat Oncol 9:20

    Article  CAS  PubMed  Google Scholar 

  • Campana LG, Mocellin S, Basso M et al (2009) Bleomycin-based electrochemotherapy: clinical outcome from a single institution’s experience with 52 patients. Ann Surg Oncol 16:191–199

    Article  PubMed  Google Scholar 

  • Cemazar M, Jarm T, Miklavcic D et al (1998) Effect of electric-field intensity on electropermeabilization and electrosensitivity of various tumor-cell lines in vitro. Electro Magnetobiol 17:263–272

    Google Scholar 

  • Corovic S, Zupanic A, Miklavcic D (2008) Numerical modeling and optimization of electric field distribution in subcutaneous tumor treated with electrochemotherapy using needle electrodes. IEEE Trans Plasma Sci 36:1665–1672

    Article  Google Scholar 

  • Corovic S, Zupanic A, Kranjc S et al (2010) In vivo electroporation detection based on magnetic resonance imaging, propidium iodide fluorescence and numerical modeling of anisotropic muscle tissue. Med Biol Eng Comput 48:637–648

    Article  PubMed  Google Scholar 

  • Cukjati D, Batiuskaite D, Andre F et al (2007) Real time electroporation control for accurate and safe in vivo non-viral gene therapy. Bioelectrochemistry 70:501–507

    Article  CAS  PubMed  Google Scholar 

  • Daniels C, Rubinsky B (2009) Electrical field and temperature model of nonthermal irreversible electroporation in heterogeneous tissues. J Biomech Eng 131:071006

    Article  PubMed  Google Scholar 

  • Davalos RV, Mir LM, Rubinsky B (2005) Tissue ablation with irreversible electroporation. Ann Biomed Eng 33:223–231

    Article  CAS  PubMed  Google Scholar 

  • Gabriel S, Lau RW, Gabriel C (1996) The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol 41:2251–2269

    Article  CAS  PubMed  Google Scholar 

  • Gabriel C, Peyman A, Grant EH (2009) Electrical conductivity of tissue at frequencies below 1 MHz. Phys Med Biol 54:4863–4878

    Article  CAS  PubMed  Google Scholar 

  • Goldberg A, Rubinsky B (2010) A statistical model for multidimensional irreversible electroporation cell death in tissue. Biomed Eng Online 9:13

    Article  Google Scholar 

  • Haemmerich D, Schutt DJ, Wright AW et al (2009) Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation. Physiol Meas 30:459–466

    Article  PubMed  Google Scholar 

  • Ivorra A, Al-Sakere B, Rubinsky B et al (2009) In vivo electrical conductivity measurements during and after tumor electroporation: conductivity changes reflect the treatment outcome. Phys Med Biol 54:5949–5963

    Article  PubMed  Google Scholar 

  • Marty M, Sersa G, Garbay JR et al (2006) Electrochemotherapy––an easy, highly effective and safe treatment of cutaneous and subcutaneous metastases: results of ESOPE (European Standard Operating Procedures of Electrochemotherapy) study. EJC Suppl 4:3–13

    CAS  Google Scholar 

  • Miklavcic D, Beravs K, Semrov D et al (1998) The importance of electric field distribution for effective in vivo electroporation of tissues. Biophys J 74:2152–2158

    Article  CAS  PubMed  Google Scholar 

  • Miklavcic D, Semrov D, Mekid H et al (2000) A validated model of in vivo electric field distribution in tissues for electrochemotherapy and for DNA electrotransfer for gene therapy. Biochim Biophys Acta 1523:73–83

    CAS  PubMed  Google Scholar 

  • Miklavcic D, Corovic S, Pucihar G et al (2006a) Importance of tumour coverage by sufficiently high local electric field for effective electrochemotherapy. EJC Suppl 4:45–51

    Google Scholar 

  • Miklavcic D, Pavselj N, Hart FX (2006b) Electric properties of tissues. In: Wiley encyclopedia of biomedical engineering. John Wiley and Sons, New York

  • Miklavcic D, Snoj M, Zupanic A et al (2010) Towards treatment planning and treatment of deep seated solid tumors by electrochemotherapy. Biomed Eng Online 9:10

    Article  PubMed  Google Scholar 

  • Mir LM, Gehl J, Sersa G et al (2006) Standard operating procedures of the electrochemotherapy: instructions for the use of bleomycin or cisplatin administered either systemically or locally and electric pulses delivered by the CliniporatorTM by means of invasive or non-invasive electrodes. EJC Suppl 4:14–25

    CAS  Google Scholar 

  • Neal RE, Davalos RV (2009) The feasibility of irreversible electroporation for the treatment of breast cancer and other heterogeneous systems. Ann Biomed Eng 37:2615–2625

    Article  PubMed  Google Scholar 

  • Orlowski S, Belehradek J, Paoletti C et al (1988) Transient electropermeabilization of cells in culture––increase of the cyto-toxicity of anticancer drugs. Biochem Pharmacol 37:4727–4733

    Article  CAS  PubMed  Google Scholar 

  • Pavselj N, Miklavcic D (2009) Numerical modeling in electroporation-based biomedical applications. Radiol Oncol 42:159–168

    Article  Google Scholar 

  • Pavselj N, Bregar Z, Cukjati D et al (2005) The course of tissue permeabilization studied on a mathematical model of a subcutaneous tumor in small animals. IEEE Trans Biomed Eng 52:1373–1381

    Article  PubMed  Google Scholar 

  • Rebersek M, Faurie C, Kanduser M et al (2007) Electroporator with automatic change of electric field direction improves gene electrotransfer in vitro. Biomed Eng Online 6:25

    Article  PubMed  Google Scholar 

  • Rubinsky B, Onik G, Mikus P (2007) Irreversible electroporation: a new ablation modality—clinical implications. Technol Cancer Res Treat 6:37–48

    PubMed  Google Scholar 

  • Sel D, Cukjati D, Batiuskaite D et al (2005) Sequential finite element model of tissue electropermeabilization. IEEE Trans Biomed Eng 52:816–827

    Article  PubMed  Google Scholar 

  • Sel D, Lebar AM, Miklavcic D (2007) Feasibility of employing model-based optimization of pulse amplitude and electrode distance for effective tumor electropermeabilization. IEEE Trans Biomed Eng 54:773–781

    Article  PubMed  Google Scholar 

  • Sersa G, Cemazar M, Miklavcic D (1995) Antitumor effectiveness of electrochemotherapy with cis-diamminedichloroplatinum(II) in mice. Cancer Res 55:3450–3455

    CAS  PubMed  Google Scholar 

  • Sersa G, Miklavcic D, Cemazar M et al (2008) Electrochemotherapy in treatment of tumours. Eur J Surg Oncol 34:232–240

    CAS  PubMed  Google Scholar 

  • Zupanic A, Corovic S, Miklavcic D (2008) Optimization of electrode position and electric pulse amplitude in electrochemotherapy. Radiol Oncol 42:93–101

    Article  Google Scholar 

Download references

Acknowledgement

This research was supported by the Slovenian Research Agency (ARRS) under various grants.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Damijan Miklavcic.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kos, B., Zupanic, A., Kotnik, T. et al. Robustness of Treatment Planning for Electrochemotherapy of Deep-Seated Tumors. J Membrane Biol 236, 147–153 (2010). https://doi.org/10.1007/s00232-010-9274-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00232-010-9274-1

Keywords

Navigation