Abstract
The objective of this paper is to describe the implementation of a software application, called ApOtEl, developed for needle electrodes positioning optimization for electrochemotherapy procedures in the treatment of cutaneous and subcutaneous tumors. The software was developed using MATLABĀ®, and it optimizes the needle-type electrodes positioning configurations, through the study of the analytical electric field, using Laplace equation in a homogeneous bi-dimensional environment. The optimization was based on requirements chosen to guarantee the tumor total coverage and to minimize healthy neighboring tissues damage. An optimization function was created to orientate the electrochemotherapy application, and the best option available in all configurations generated by the distance variations between electrodes and positioning orientations was determined. The software provides, by the entry of tumor dimensions, the optimized distances for positioning needle-type electrodes, as well as the representation of the electric field distribution and intensity. Representation of the electrodes positioning and instructions for the procedure to facilitate the procedure planning are provided.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Haberl, S., et al.: Cell membrane electroporationāpart: the applications. IEEE Electr Insul Mag 29 (1), 29ā37 (2013).
PavÅ”elj, N., MiklavÄiÄ, D.: Numerical modeling in electroporation-based biomedical applications. Radiol Oncol 42 (3), 159ā68 (2008).
TellĆ³, M.: Uso da corrente elĆ©trica no tratamento do cĆ¢ncer. 1st ed. EDIPUCRS, Porto Alegre (2004).
ÄoroviÄ, S.: ModĆ©lisation et visualisation de lāĆ©lectropermĆ©abilisation dans des tissus biologiques exposĆ©s Ć des impulsions Ć©lectriques de haut voltage. PhD (dissertation). Paris Sud: Paris (2010).
Calvet, C. Y., Mir, L. M.: The promising alliance of anti-cancer electrochemotherapy with immunotherapy. Cancer Metastasis Rev 35 (2), 165ā177 (2016).
Compliance with ethical standards
Conflicts of interest: The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
Ā© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
da Silva, L.E.R., Tello, M., de Azevedo, D.F.G., da Silva, A.M.M. (2019). ApOtEl: Development of a Software for Electroporation Based Therapy Planning. In: Lhotska, L., Sukupova, L., LackoviÄ, I., Ibbott, G. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/3. Springer, Singapore. https://doi.org/10.1007/978-981-10-9023-3_42
Download citation
DOI: https://doi.org/10.1007/978-981-10-9023-3_42
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-9022-6
Online ISBN: 978-981-10-9023-3
eBook Packages: EngineeringEngineering (R0)