Abstract
Purpose
The purpose of this study was to evaluate three different non-invasive measuring devices for the pivot shift phenomenon with reference to direct bony movement measured by an electromagnetic device rigidly attached to the tibia and femur.
Methods
A lower body cadaveric specimen was prepared to create a positive pivot shift in both knees. Twelve expert knee surgeons from worldwide performed their preferred pivot shift technique three times in each knee. After watching an instructional video, the examiners used a standardized technique to perform three additional pivot shift maneuvers in each knee. An electromagnetic tracking system, rigidly attached to femur and tibia, was used to provide reference measurements during the pivot shift test. Three different devices were correlated to the reference method and evaluated in this study: (1) Electromagnetic tracking system with skin sensors; (2) Triaxial accelerometer system; (3) Simple image analysis.
Results
When results from both pivot shift techniques (preferred and standardized) were combined, the electromagnetic tracking system with skin sensors showed positive correlation with the reference measurement for acceleration and translation parameters (r = 0.88 and r = 0.67, respectively; both P < 0.01); The triaxial accelerometer system demonstrated good correlation with the reference measurement for acceleration (r = 0.75; P < 0.001). The image analysis system was poorly correlated to the translation of the reference measurement (r = 0.24; P < 0.01).
Conclusion
The electromagnetic tracking system with skin sensors provided the best correlation with the reference method. The triaxial accelerometer showed also a good correlation and the image analysis system showed a positive, but poor correlation with the reference method. More research is needed in order to validate simple and non-invasive devices for clinical application.
Similar content being viewed by others
References
Galway HR, MacIntosh DL (1980) The lateral pivot shift: a symptom and sign of anterior cruciate ligament insufficiency. Clin Orthop Relat Res 147:45–50
Slocum DB, James SL, Larson RL, Singer KM (1976) Clinical test for anterolateral rotary instability of the knee. Clin Orthop Relat Res 118:63–69
Kuroda R, Hoshino Y, Kubo S, Araki D, Oka S, Nagamune K, Kurosaka M (2011) Similarities and differences of diagnostic manual tests for anterior cruciate ligament insufficiency: a global survey and kinematics assessment. Am J Sports Med 14(5):236–255. doi:10.1177/0363546511423634
Noyes FR, Grood ES, Cummings JF, Wroble RR (1991) An analysis of the pivot shift phenomenon: the knee motions and subluxations induced by different examiners. Am J Sports Med 19(2):148–155
Bedi A, Musahl V, Lane C, Citak M, Warren RF, Pearle AD (2010) Lateral compartment translation predicts the grade of pivot shift: a cadaveric and clinical analysis. Knee Surg Sports Traumatol Arthrosc 18(9):1269–1276
Bignozzi S, Zaffagnini S, Lopomo N, Fu FH, Irrgang JJ, Marcacci M (2010) Clinical relevance of static and dynamic tests after anatomical double-bundle ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 18(1):37–42
Hoshino Y, Kuroda R, Nagamune K, Yagi M, Mizuno K, Yamaguchi M, Muratsu H, Yoshiya S, Kurosaka M (2007) In vivo measurement of the pivot-shift test in the anterior cruciate ligament-deficient knee using an electromagnetic device. Am J Sports Med 35(7):1098–1104
Katchburian M, Hassan A, Amis A (2002) Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament. J Bone Jt Surg Br 84(7):1075–1081
Labbe DR, de Guise JA, Mezghani N, Godbout V, Grimard G, Baillargeon D, Lavigne P, Fernandes J, Ranger P, Hagemeister N (2010) Feature selection using a principal component analysis of the kinematics of the pivot shift phenomenon. J Biomech 43(16):3080–3084
Lane CG, Warren RF, Stanford FC, Kendoff D, Pearle AD (2008) In vivo analysis of the pivot shift phenomenon during computer navigated ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 16(5):487–492
Lopomo N, Zaffagnini S, Bignozzi S, Visani A, Marcacci M (2010) Pivot-shift test: analysis and quantification of knee laxity parameters using a navigation system. J Orthop Res 28(2):164–169
Maeyama A, Hoshino Y, Debandi A, Kato Y, Saeki K, Asai S, Goto B, Smolinski P, Fu FH (2011) Evaluation of rotational instability in the anterior cruciate ligament deficient knee using triaxial accelerometer: a biomechanical model in porcine knees. Knee Surg Sports Traumatol Arthrosc 19(8):1233–1238
Pearle AD, Kendoff D, Musahl V, Warren RF (2009) The pivot-shift phenomenon during computer-assisted anterior cruciate ligament reconstruction. J Bone Jt Surg Am 91(Suppl 1):115–118
Hoshino Y, Kuroda R, Nagamune K, Nishimoto K, Yagi M, Mizuno K, Yoshiya S, Kurosaka M (2007) The effect of graft tensioning in anatomic 2-bundle ACL reconstruction on knee joint kinematics. Knee Surg Sports Traumatol Arthrosc 15(5):508–514
Hardaker WT, Garrett WE, Bassett FH (1990) Evaluation of acute traumatic hemarthrosis of the knee joint. South Med J 83(6):640–644
Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105(2):136–144
Nishimoto K, Kuroda R, Mizuno K, Hoshino Y, Nagamune K, Kubo S, Yagi M, Yamaguchi M, Yoshiya S, Kurosaka M (2008) Analysis of the graft bending angle at the femoral tunnel aperture in anatomic double bundle anterior cruciate ligament reconstruction: a comparison of the transtibial and the far anteromedial portal technique. Knee Surg Sports Traumatol Arthrosc 17(3):270–276
Araki D, Kuroda R, Kubo S, Fujita N, Tei K, Nishimoto K, Hoshino Y, Matsushita T, Matsumoto T, Nagamune K, Kurosaka M (2010) A prospective randomised study of anatomical single-bundle versus double-bundle anterior cruciate ligament reconstruction: quantitative evaluation using an electromagnetic measurement system. Int Orthop 35(3):439–446
Fujita N, Kuroda R, Matsumoto T, Yamaguchi M, Yagi M, Matsumoto A, Kubo S, Matsushita T, Hoshino Y, Nishimoto K, Araki D, Kurosaka M (2011) Comparison of the clinical outcome of double-bundle, anteromedial single-bundle, and posterolateral single-bundle anterior cruciate ligament reconstruction using hamstring tendon graft with minimum 2-year follow-up. Arthroscopy 27(7):906–913
Hoshino Y, Kuroda R, Nagamune K, Araki D, Kubo S, Yamaguchi M, Kurosaka M (2011) Optimal measurement of clinical rotational test for evaluating anterior cruciate ligament insufficiency. Knee Surg Sports Traumatol Arthrosc 36(34):125–136. doi:10.1007/s00167-011-1643-5
Kubo S, Muratsu H, Yoshiya S, Mizuno K, Kurosaka M (2007) Reliability and usefulness of a new in vivo measurement system of the pivot shift. Clin Orthop Relat Res 454:54–58
Yagi M, Kuroda R, Nagamune K, Yoshiya S, Kurosaka M (2007) Double-bundle ACL reconstruction can improve rotational stability. Clin Orthop Relat Res 454:100–107
Nafis C, Jensen V, Beauregard L, Anderson P (2006) Method for estimating dynamic EM tracking accuracy of surgical navigation tools. Progr Biomed Opt Imaging—Proc SPIE 6141:152–167
Benjaminse A, Gokeler A, van der Schans CP (2006) Clinical diagnosis of an anterior cruciate ligament rupture: a meta-analysis. J Orthop Phys Ther 36(5):267–288
Boeree NR, Ackroyd CE (1991) Assessment of the menisci and cruciate ligaments: an audit of clinical practice. Injury 22(4):291–294
Richter J, Dàvid A, Pape HG, Ostermann PA, Muhr G (1996) Diagnosis of acute rupture of the anterior cruciate ligament: value of ultrasonic in addition to clinical examination. Der Unfallchirurg 99(2):124–129
Rubinstein RA, Shelbourne KD, McCarroll JR, VanMeter CD, Rettig AC (1994) The accuracy of the clinical examination in the setting of posterior cruciate ligament injuries. Am J Sports Med 22(4):550–557
Steinbrück K, Wiehmann JC (1988) Examination of the knee joint: the value of clinical findings in arthroscopic control. Zeitschrift für Orthopädie und ihre Grenzgebiete 126(3):289–295
Lopomo N, Zaffagnini S, Signorelli C, Bignozzi S, Giordano G, Marcheggiani Muccioli GM, Visani A (2011) An original clinical methodology for non-invasive assessment of pivot-shift test. Comput Methods Biomech Biomed Eng 12(23):125–136. doi:10.1080/10255842.2011.591788
Acknowledgments
The authors would like to sincerely thank the expert surgeons for their participation and inspiring comments during the study (Drs. Roland Becker, Shiyi Chen, Moises Cohen, Andreas Imhoff, Timo Jarvela, Jon Karlsson, Masahiro Kurosaka, Benjamin Ma, Willem van der Merwe, Philippe Neyret, Robert Smigielski, Stefano Zaffagnini).
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Supplementary material 1 (WMV 5,476 kb)
Rights and permissions
About this article
Cite this article
Araujo, P.H., Ahlden, M., Hoshino, Y. et al. Comparison of three non-invasive quantitative measurement systems for the pivot shift test. Knee Surg Sports Traumatol Arthrosc 20, 692–697 (2012). https://doi.org/10.1007/s00167-011-1862-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-011-1862-9