Skip to main content
Log in

In vivo analysis of the pivot shift phenomenon during computer navigated ACL reconstruction

  • Knee
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

ACL insufficiency can be documented clinically with the pivot shift maneuver, but the specific pathologic kinematics of the pivot shift is difficult to quantify. Navigation provides an opportunity to analyze in vivo the motions that comprise the pivot shift and the kinematic changes that are inherent after ACL reconstruction. We hypothesized that tibial rotation, anterior tibial translation (ATT), acceleration of posterior translation (APT) and the newly described angle of P, quantified during navigated pivot shift examination, correlate with clinical grading of the pivot shift phenomena. Navigation data from 12 patients who underwent navigated ACL surgery were retrospectively reviewed. A characteristic P-shaped track of motion is recorded by the navigation software during the pivot-shift examination. The “angle of P” was developed as a means characterizing this track of motion and was measured in all cases. The tibial rotation, maximum anterior tibial translation and acceleration of posterior translation during the pivot shift were also measured. The charts of these patients were reviewed to obtain information on the clinical grading of the pivot-shift before and after ACL reconstruction. Spearman correlation analysis was then used to identify significant correlations between clinical grade of the pivot shift and the angle of p measured with computer navigation. After reconstruction, the clinical grade of the pivot shift was zero in all patients. The tibial rotation, maximum ATT, APT and the angle of p also decreased. On analysis of 24 EUAs, 12 before reconstruction and 12 after, there was excellent and significant correlation between the clinical grade of pivot shift examination and the angle of P (R 2 = 0.97, p < 0.001). Only good correlation was noted between the clinical pivot shift and the rotation (R 2 = 0.77, p < 0.0001), maximum ATT (R 2 = 0.87, p < 0.0001) and APT (R 2 = 0.81, p < 0.0001). There was a stepwise increase of 6–7 mm of translation and 5–6° of rotation for each increasing grade of pivot shift. There were also increases in the angle of P and APT for each increasing grade of pivot. A decrease in tibial rotation, maximum ATT, APT and angle of p is detected by computer navigation with ACL reconstruction, correlating with clinical grading. Clinical quantification of the distinct elements of the pivot shift may allow for more accurate evaluation of different ACL reconstruction constructs. There is also potential for these variables to be measured intraoperatively and guide ACL reconstruction when computer navigation is employed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Bach BR Jr, Warren RF, Wickiewicz TL (1988) The pivot shift phenomenon: results and description of a modified clinical test for anterior cruciate ligament insufficiency. Am J Sports Med 16(6):571–576

    Article  PubMed  Google Scholar 

  2. Benjaminse A, Gokeler A, van der Schans CP (2006) Clinical diagnosis of an anterior cruciate ligament rupture: a meta-analysis. J Orthop Sports Phys Ther 36(5):267–288

    PubMed  Google Scholar 

  3. Bull AM, Amis AA (1998) The pivot-shift phenomenon: a clinical and biomechanical perspective. Knee 5:141–158

    Article  Google Scholar 

  4. Bull AM, Earnshaw PH, Smith A et al (2002) Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br 84(7):1075–1081

    Article  PubMed  CAS  Google Scholar 

  5. Colombet P, Robinson JFRCS, Christel P et al (2007) Using navigation to measure rotation kinematics during ACL Reconstruction. Report. Clin Orthop Relat Res 454:59–65

    Article  PubMed  Google Scholar 

  6. Daniel DM, Malcom LL, Losse G et al (1985) Instrumented measurement of anterior laxity of the knee. J Bone Joint Surg Am 67(5):720–726

    PubMed  CAS  Google Scholar 

  7. Fukuda Y, Woo SL, Loh JC et al (2003) A quantitative analysis of valgus torque on the ACL: a human cadaveric study. J Orthop Res 21(6):1107–1112

    Article  PubMed  Google Scholar 

  8. Galway HR, MacIntosh DL (1980) The lateral pivot shift: a symptom and sign of anterior cruciate ligament insufficiency. Clin Orthop (147):45–50

  9. Georgoulis AD, Ristanis S, Chouliaras V et al (2007) Tibial rotation is not restored after ACL reconstruction with a hamstring graft. Report. Clin Orthop Relat Res 454:89–94

    Article  PubMed  Google Scholar 

  10. Hoshino Y, Kuroda R, Nagamune K et al (2007) In vivo measurement of the pivot-shift test in the anterior cruciate ligament-deficient knee using an electromagnetic device. Am J Sports Med 35(7):1098–1104

    Article  PubMed  Google Scholar 

  11. Jonsson H, Riklund-Ahlstrom K, Lind J (2004) Positive pivot shift after ACL reconstruction predicts later osteoarthrosis: 63 patients followed 5–9 years after surgery. Acta Orthop Scand 75(5):594–599

    Article  PubMed  Google Scholar 

  12. Kanamori A, Zeminski J, Rudy TW et al (2002) The effect of axial tibial torque on the function of the anterior cruciate ligament: a biomechanical study of a simulated pivot shift test. Arthroscopy 18(4):394–398

    Article  PubMed  Google Scholar 

  13. Kaplan N, Wickiewicz TL, Warren RF (1990) Primary surgical treatment of anterior cruciate ligament ruptures. A long-term follow-up study. Am J Sports Med 18(4):354–358

    Article  PubMed  CAS  Google Scholar 

  14. Kocher MS, Steadman JR, Briggs KK et al (2004) Relationships between objective assessment of ligament stability and subjective assessment of symptoms and function after anterior cruciate ligament reconstruction. Am J Sports Med 32(3):629–634

    Article  PubMed  Google Scholar 

  15. Kubo S, Muratsu H, Yoshiya S et al (2007) Reliability and usefulness of a new in vivo measurement system of the pivot shift. Clin Orthop 454:54–58

    Article  PubMed  Google Scholar 

  16. Kvist J (2004) Rehabilitation following anterior cruciate ligament injury: current recommendations for sports participation. Sports Med 34(4):269–280

    Article  PubMed  Google Scholar 

  17. Leitze Z, Losee RE, Jokl P et al (2005) Implications of the pivot shift in the ACL-deficient knee. Clin Orthop (436):229–236

  18. Lie DT, Bull AM, Amis AA (2007) Persistence of the mini pivot shift after anatomically placed anterior cruciate ligament reconstruction. Clin Orthop Rel Res 457:203–209

    Google Scholar 

  19. Noyes FR, Grood ES, Cummings JF et al (1991) An analysis of the pivot shift phenomenon. The knee motions and subluxations induced by different examiners. Am J Sports Med 19(2):148–155

    Article  PubMed  CAS  Google Scholar 

  20. Pearle AD, Solomon DJ, Wanich T et al (2007) Reliability of navigated knee stability examination. Am J Sports Med 35(8):1315–1320

    Article  PubMed  Google Scholar 

  21. Plaweski S, Cazal J, Rosell P et al (2006) Anterior cruciate ligament reconstruction using navigation: a comparative study on 60 patients. Am J Sports Med 34(4):542–552

    Article  PubMed  Google Scholar 

  22. Tashman S, Kolowich P, Collon D et al (2007) Dynamic function of the ACL-reconstructed knee during running. Report. Clin Orthop Rel Res 454:66–73

    Article  Google Scholar 

  23. Woo SL, Kanamori A, Zeminski J et al (2002) The effectiveness of reconstruction of the anterior cruciate ligament with hamstrings and patellar tendon. A cadaveric study comparing anterior tibial and rotational loads. J Bone Joint Surg Am 84-A(6):907–914

    PubMed  Google Scholar 

Download references

Conflict of interest statement

No professional or private funding was received for this study. There were no conflicts of interest of any author of our manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Andrew D. Pearle.

Additional information

Ethical statement: All experiments of our study have been approved by the Ethical Committee of Hospital for Special Surgery.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lane, C.G., Warren, R.F., Stanford, F.C. et al. In vivo analysis of the pivot shift phenomenon during computer navigated ACL reconstruction. Knee Surg Sports Traumatol Arthr 16, 487–492 (2008). https://doi.org/10.1007/s00167-008-0504-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00167-008-0504-3

Keywords

Navigation