Abstract
The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology, Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This project aimed to study some basic physical characteristics of this new type of cassette and explore its application for performing quality assurance (QA) tests and portal imaging in radiotherapy. All the images were read by FCR 5000 Plus reader. The image was found to reach its saturation value of 1023 (due to the image was stored in 10 bits data) by depending on the sensitivity value being adjusted. The uniformity test gave the result of 0.12%. The cassette was used to perform the QA tests which were previously performed using film. All the results met the specification as stated in AAPM Task Group 40. The comparison for the portal images of PortalVisionTM contrastdetail phantom showed that the spatial resolution of the images obtained by CR system (Fujifilm Co., Ltd., Tokyo, Japan) were better than the EPID (Varian Medical Systems, Inc., Palo Alto, USA) and film system (Eastman Kodak Co., New York, USA). The IP cassette type PII was found to be suitable as an alternative QA test tool and portal imaging in radiotherapy.
Similar content being viewed by others
References
Ng, K.H. and Rehani, M.M.,X-ray imaging goes digital, BMJ, 333: 765–766, 2006.
Geyer, P., Blank, H. and Alheit, H.,Portal Verification Using the KODAK ACR 2000 RT Storage Phosphor Plate System and EC ® Films: A Semiquantitative Comparison, Strahlenther Onkol, 3: 172–178, 2006.
Lindhardt, F.E.,Clinical experiences with computed radiography. Eur J Radiol. 22: 175–185, 1996.
Khan, F.M.,The Physics of Radiation Therapy, 3rd ed., Williams and Wilkins, USA, 424–454, 2003.
Herman, M.G., Kruse, J.J. and Hagness, C.R.,Guide to clinical use of electronic portal imaging, J Appl Clin Med Physc, 1: 38–57, 2000.
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M. and Boone, J. M.,The Essential Physics of Medical Imaging. 2nd ed., Lippincott Williams and Wilkins, USA, 293–316, 2002.
Zullo, J.R., Bloch, C., Chi, P.C. and Kudchadker, R.,Linearity and uniformity response as an indicator of performance for Agfa ADC-MD10 computed radiography plates, Medical Dosimetry, 29: 118–121, 2004.
Kutcher, G.J., Coia, L., Gillin, M., Hanson, W.F., Leibel, S., Morton, R.J., Palta, J.R., Purdy, J.A., Reinstein, L.E., Svensson, G.K., Weller, M. and Wingfield, L.,Comprehensive QA for Radiation Oncology, Med Phys, 21: 581–618, 1994.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Soh, H.S., Ung, N.M. & Ng, K.H. The characteristics of Fuji IP Cassette Type PII and application for radiation oncology quality assurance tests and portal imaging. Australas. Phys. Eng. Sci. Med. 31, 146–150 (2008). https://doi.org/10.1007/BF03178589
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03178589