The characteristics of Fuji IP Cassette Type PII and application for radiation oncology quality assurance tests and portal imaging

  • Technical Note
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology, Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This project aimed to study some basic physical characteristics of this new type of cassette and explore its application for performing quality assurance (QA) tests and portal imaging in radiotherapy. All the images were read by FCR 5000 Plus reader. The image was found to reach its saturation value of 1023 (due to the image was stored in 10 bits data) by depending on the sensitivity value being adjusted. The uniformity test gave the result of 0.12%. The cassette was used to perform the QA tests which were previously performed using film. All the results met the specification as stated in AAPM Task Group 40. The comparison for the portal images of PortalVisionTM contrastdetail phantom showed that the spatial resolution of the images obtained by CR system (Fujifilm Co., Ltd., Tokyo, Japan) were better than the EPID (Varian Medical Systems, Inc., Palo Alto, USA) and film system (Eastman Kodak Co., New York, USA). The IP cassette type PII was found to be suitable as an alternative QA test tool and portal imaging in radiotherapy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ng, K.H. and Rehani, M.M.,X-ray imaging goes digital, BMJ, 333: 765–766, 2006.

    Article  PubMed  Google Scholar 

  2. Geyer, P., Blank, H. and Alheit, H.,Portal Verification Using the KODAK ACR 2000 RT Storage Phosphor Plate System and EC ® Films: A Semiquantitative Comparison, Strahlenther Onkol, 3: 172–178, 2006.

    Article  Google Scholar 

  3. Lindhardt, F.E.,Clinical experiences with computed radiography. Eur J Radiol. 22: 175–185, 1996.

    Article  CAS  PubMed  Google Scholar 

  4. Khan, F.M.,The Physics of Radiation Therapy, 3rd ed., Williams and Wilkins, USA, 424–454, 2003.

    Google Scholar 

  5. Herman, M.G., Kruse, J.J. and Hagness, C.R.,Guide to clinical use of electronic portal imaging, J Appl Clin Med Physc, 1: 38–57, 2000.

    Article  CAS  Google Scholar 

  6. Bushberg, J. T., Seibert, J. A., Leidholdt, E. M. and Boone, J. M.,The Essential Physics of Medical Imaging. 2nd ed., Lippincott Williams and Wilkins, USA, 293–316, 2002.

    Google Scholar 

  7. Zullo, J.R., Bloch, C., Chi, P.C. and Kudchadker, R.,Linearity and uniformity response as an indicator of performance for Agfa ADC-MD10 computed radiography plates, Medical Dosimetry, 29: 118–121, 2004.

    Article  PubMed  Google Scholar 

  8. Kutcher, G.J., Coia, L., Gillin, M., Hanson, W.F., Leibel, S., Morton, R.J., Palta, J.R., Purdy, J.A., Reinstein, L.E., Svensson, G.K., Weller, M. and Wingfield, L.,Comprehensive QA for Radiation Oncology, Med Phys, 21: 581–618, 1994.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. M. Ung.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Soh, H.S., Ung, N.M. & Ng, K.H. The characteristics of Fuji IP Cassette Type PII and application for radiation oncology quality assurance tests and portal imaging. Australas. Phys. Eng. Sci. Med. 31, 146–150 (2008). https://doi.org/10.1007/BF03178589

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178589

Key words

Navigation