Abstract
Thirty-three patients suspected of suffering from inflammatory bowel disease were studied. Autologous leucocytes were labelled with indium 111 oxine and re-injected simultaneously with 0.3–0.5 mg of technetium 99m granulocyte-specific monoclonal antibody BW 250/183. Two scans were obtained, the early scan 3–4 h postinjection (p.i.) and the late scan 18–24 h p.i. Using the endoscopy study as standard, the diagnostic accuracy of both agents was determined. Sensitivity, specificity and accuracy of111In scans was 88.8%, 100.0% and 93.7% at 4 h and 94.7%, 100.0% and 96.9% at 24 h, respectively. Concerning the results using antibodies, the values were 61.1%, 100.0% and 78.1% at 4 h and 78.9%, 92.8% and 84.8% at 24 h, respectively. Segmental analysis showed concordance in 89.3% and 93.3% of the cases at 4 and 24 h, respectively. Though less sensitive and less accurate than scanning employing indium 111 leucocytes, BW 250/183 granulocyte-specific scintigraphy can be used for inflammatory bowel disease diagnosis and localization.
Similar content being viewed by others
References
Andres RY, Schubiger PA, Tiefenauer L, Seybold K, Locher JT, Mach JP, Buchegger F (1988) Immunoscintigraphic localization of inflammatory lesions: concept, radiolabelling and in vitro testing of a granulocyte-specific antibody. Eur J Nucl Med 13:582–586
Becker W, Fischbach W, Weppler W, Mosl M, Jacoby G, Börner W (1988) Radiolabeled granulocytes in inflammatory bowel disease: diagnostic possibilities and clinical indications. Nucl Med Commun 9:693–701
Froelich JW, Field SA (1988) The role of111In white blood cells in inflammatory bowel disease. Serum Nucl Med 18:300–307
Joseph K, Höfken H, Bosslet K, Schorlemmer HU (1988) In vivo labelling of granulocytes with99mTc anti-NCA monoclonal antibodies for imaging inflammation. Eur J Nucl Med 14: 367–373
Kroiss A, Weiss W, Auinger C, Kölbl, Weidlich G, Feichtenschlager T, Neumayr A (1989) Immunoscintigraphy with123I and99mTc labelled granulocytes antibody in patients with inflammatory bowel disease. Nucl Med [Suppl] 26:394–396
Lind P, Langsteger W, Koltringer P, Dimai HP, Passl R, Eber O (1990) Immunoscintigraphy of inflammatory processes with a99mTc-labeled monoclonal antigranulocyte antibody (MAb BW 250/183). J Nucl Med 31:417–423
Locher IT, Seybold K, Andres RY, Schubiger PA, Mach JP, Buchegger F (1986) Imaging of inflammatory and infectious lesions after injection of radioiodinated monoclonal antigranulocyte antibodies. Nucl Med Commun 7:659–670
Peters AM, Saverymuttu SH, and Lavender JP (1983) Granulocyte kinetics. In: Thakur ML (ed) Radiolabelled cellular blood element. Pathophysiology, techniques and scintigraphic applications. Plenum Press, New York, pp 285–303 (NATO ASI series)
Saverymuttu SH, Petrs AM, Hodgson HJ, Chadwick VS, Lavender JP (1982)111In autologous leucocyte scanning: comparison with radiology for imaging the colon in inflammatory bowel disease. BMJ 285:255–257
Schwarz A, Steinstraesser A (1987) A novel approach to99mTc labeled monoclonal antibodies. J Nucl Med 28:721 (abstract)
Segal AW, Ensell J, Munro J, Sarner M (1981)111 In-tagged leucocytes in the diagnosis of inflammatory bowel disease. Lancet 11:230–232
Thakur ML, Richard MD, White FW III (1988) Monoclonal antibodies as agents for selective radiolabelling of human neutrophils. J Nucl Med 29:1817–1825
Ybern A, Martin-Comin J, Gine JJ, Casanovas T, Villa R, MA Gasull (1986)111In-oxine labelled autologous leucocytes in inflammatory bbwel disease: new scintigraphic activity index. Eur J Nucl Med 11:341–344
Author information
Authors and Affiliations
Additional information
Offprint requests to: J. Martin-Comin
Rights and permissions
About this article
Cite this article
Segarra, I., Roca, M., Baliellas, C. et al. Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease. Eur J Nucl Med 18, 715–719 (1991). https://doi.org/10.1007/BF00956711
Received:
Revised:
Issue Date: