Abstract

An automated flow injection system for on-line analysis of proteins in real fermentation fluids was developed by combining the principles of stopped-flow, merging zones flow injection analysis (FIA) with antigen-antibody reactions. IgG in the sample reacted with its corresponding antibody (a-IgG) in the reagent solution. Formation of insoluble immunocomplexes resulted in an increase of the turbidity which was determined photometrically. This system was used to monitor monoclonal antibody production in high cell density perfusion culture of hybridoma cells. Perfusion was performed with a newly developed static filtration unit equipped with hydrophilic microporous tubular membranes. Different sampling devices were tested to obtain a cell-free sample stream for on-line product anlysis of high molecular weight (e.g., monoclonal antibodies) and low molecular weight (e.g., glucose, lactate) medium components. In fermentation fluids a good correlation (coefficient: 0.996) between the FIA method and an ELISA test was demonstrated. In a high density perfusion cultivation process mAb formation was succesfully monitored on-line over a period of 400 h using a reliable sampling system. Glucose and lactate were measured over the same period of time using a commercially available automatic analyser based on immobilized enzyme technology.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

TIA:

Turbidimetric immunoassay

mAb:

Monoclonal Antibody

References

  • Bradford, MM (1976) A rapid and sensitive method for the quantitation of microgram quantities of protein using the principle of protein-dye binding. Anal. Biochem. 72: 248–254.

    Google Scholar 

  • Fraune E, Fenge C and Kuhlmann W (1988) High density hybridoma cell culture in stirred tank perfusion bioreactors. Abstract Book 8th International Biotechnology Symposium, Paris, 115.

  • Freitag R (1989) PhD Thesis. University of Hannover.

  • Freitag R, Scheper T Schügerl K (in press) Development of a turbidimetric immunoassay for on-line monitoring biomolecules of high molecular weight. J. Biotechnol.

  • Garn, M, Gisin, M and Thommen, C (1989) A flow injection analysis system for fermentation monitoring and control. Biotechnol. Bioeng. 34: 423–428.

    Google Scholar 

  • Glacken, MW, Fleischaker, RJ and Sinkskey, AJ (1986) Reduction of waste product excretion via nutrient control: possible strategies for maximizing product and cell yields on serum in cultures of mammalian cells. Biotechnol. Bioeng. 28: 1376–1389

    Google Scholar 

  • Kroner KH and Papamicheal N (1988) Continuous sampling technique for on-line analysis. Process Biochemistry Probiotech: iii–vi.

  • Reuveny, S, Velez, D, Miller, L and Macmillen, JD (1986) Comparison of cell propagation methods for their effect on monoclonal antibody yield in fermentors. J. Immunol. Meth. 86: 61–69.

    Google Scholar 

  • Reitzer, LJ, Wice, BM and Kenell, D (1979) Evidence that glutamine, not sugar, is the major energy source for cultured HeLa cells. J. Biolog. Chem. 254: 2669–2676.

    Google Scholar 

  • Ruzicka, J and Hansen, EH (1983) Recent developments in flow injection analysis: gradient techniques and hydrodynamic injection. Anal. Chim. Acta 145: 1.

    Google Scholar 

  • Schendel, FJ, Baude, EJ and Flickinger, MC (1989) Determination of protein expression and plasmid copy number from cloned genes in Escherichia coli by flow injection analysis using an enzyme indicator vector. Biotechnol. Bioeng. 34: 1023–1036.

    Google Scholar 

  • Schroer, J, Bender, T, Feldmann, RJ and Kim, KJ (1983) Mapping epitopes on the insulin molecule using monoclonal antibodies. Eur. J. Immunol. 13: 693–700.

    Google Scholar 

  • Takazawa, Y, Tokashiki, M, Hamamoto, K and Murakami, H (1988) High cell density perfusion culture of hybridoma cells recycling high molecular weight components. Cytotechnol. 1: 171–178.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fenge, C., Fraune, E., Freitag, R. et al. On-line monitoring of monoclonal antibody formation in high density perfusion culture using FIA. Cytotechnology 6, 55–63 (1991). https://doi.org/10.1007/BF00353703

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00353703

Key words

Navigation