Skip to main content

Trunnionosis in Total Hip Arthroplasty

  • Chapter
  • First Online:
Hip Arthroplasty

Abstract

Trunnionosis is widely known as a possible cause of failure following total hip arthroplasty (THA). Although factors such as mechanical stress, corrosion and specific implant designs may contribute to the development of trunnionosis, the actual cause of the condition remains still unknown. Orthopedic surgeons have become more aware of trunnion failure due to the increasing rate of soft tissue reactions occurring in patients undergoing THA. This multifactorial condition should be investigated further and physicians should also consider trunnionosis in patients suffering from chronic hip pain after THA.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Lombardi AV Jr, et al. The hip society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty. J Bone Joint Surg Br. 2012;94(11 Suppl A):14–8.

    Article  PubMed  Google Scholar 

  2. Lavernia CJ, et al. Trunnion-head stresses in THA: are big heads trouble? J Arthroplast. 2015;30(6):1085–8.

    Article  Google Scholar 

  3. Pastides PS, et al. Trunnionosis: a pain in the neck. World J Orthop. 2013;4(4):161–6.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Gkagkalis G, et al. Adverse tissue reaction to corrosion at the neck-stem junction after modular primary total hip arthroplasty. Orthop Traumatol Surg Res. 2015;101(1):123–6.

    Article  CAS  PubMed  Google Scholar 

  5. Esposito CI, et al. What is the trouble with trunnions? Clin Orthop Relat Res. 2014;472(12):3652–8.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Jacobs JJ. Corrosion at the head-neck junction: why is this happening now? J Arthroplast. 2016;31(7):1378–80.

    Article  Google Scholar 

  7. McGrory BJ, MacKenzie J, Babikian G. A high prevalence of corrosion at the head-neck taper with contemporary zimmer non-cemented femoral hip components. J Arthroplast. 2015;30(7):1265–8.

    Article  Google Scholar 

  8. Matharu GS, et al. Adverse reactions to metal debris occur with all types of hip replacement not just metal-on-metal hips: a retrospective observational study of 3340 revisions for adverse reactions to metal debris from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. BMC Musculoskelet Disord. 2016;17(1):495.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Banerjee S, et al. Gross trunnion failure after primary total hip arthroplasty. J Arthroplast. 2015;30(4):641–8.

    Article  Google Scholar 

  10. Afzal I, et al. Validation of revision data for total hip and knee replacements undertaken at a high volume orthopaedic Centre against data held on the National Joint Registry. J Orthop Surg Res. 2019;14(1):318.

    Article  PubMed  PubMed Central  Google Scholar 

  11. de Steiger RN, et al. What is the risk of THA revision for ARMD in patients with non-metal-on-metal bearings? A Study from the Australian National Joint Replacement Registry. Clin Orthop Relat Res. 2020;478(6):1244–53.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Lanting B, Naudie DDR, McCalden RW. Clinical impact of trunnion wear after total hip arthroplasty. JBJS Rev. 2016;4(8)

    Google Scholar 

  13. Morlock MM, et al. Taper corrosion: a complication of total hip arthroplasty. EFORT Open Rev. 2020;5(11):776–84.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Wassef AJ, Schmalzried TP. Femoral taperosis: an accident waiting to happen? Bone Joint J. 2013;95-B(11 Suppl A):3–6.

    Article  CAS  PubMed  Google Scholar 

  15. Swaminathan V, Gilbert JL. Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces. J Biomed Mater Res A. 2013;101(9):2602–12.

    Article  PubMed  Google Scholar 

  16. Goldberg JR, et al. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002;401:149–61.

    Article  Google Scholar 

  17. Langton DJ, et al. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res. 2012;1(4):56–63.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  18. Fricka KB, et al. Metal-on-metal local tissue reaction is associated with corrosion of the head taper junction. J Arthroplast. 2012;27(8 Suppl):26–31 e1.

    Article  Google Scholar 

  19. Matsen Ko L, et al. Catastrophic femoral head-stem trunnion dissociation secondary to corrosion. J Bone Joint Surg Am. 2016;98(16):1400–4.

    Article  PubMed  Google Scholar 

  20. Cooper HJ. The local effects of metal corrosion in total hip arthroplasty. Orthop Clin North Am. 2014;45(1):9–18.

    Article  PubMed  Google Scholar 

  21. Ladon D, et al. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplast. 2004;19(8 Suppl 3):78–83.

    Article  Google Scholar 

  22. Campbell P, et al. Autopsy analysis thirty years after metal-on-metal total hip replacement. A case report. J Bone Joint Surg Am. 2003;85(11):2218–22.

    Article  PubMed  Google Scholar 

  23. Ziaee H, et al. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study. J Bone Joint Surg Br. 2007;89(3):301–5.

    Article  CAS  PubMed  Google Scholar 

  24. Cooper HJ, et al. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012;94(18):1655–61.

    Article  PubMed  Google Scholar 

  25. Urish KL, et al. Trunnion failure of the recalled low friction ion treatment cobalt chromium alloy femoral head. J Arthroplast. 2017;32(9):2857–63.

    Article  Google Scholar 

  26. Higgs GB, et al. Does taper size have an effect on taper damage in retrieved metal-on-polyethylene total hip devices? J Arthroplast. 2016;31(9 Suppl):277–81.

    Article  Google Scholar 

  27. Nassif NA, et al. Taper design affects failure of large-head metal-on-metal total hip replacements. Clin Orthop Relat Res. 2014;472(2):564–71.

    Article  PubMed  Google Scholar 

  28. Tan SC, et al. Effect of taper design on trunnionosis in metal on polyethylene total hip arthroplasty. J Arthroplast. 2015;30(7):1269–72.

    Article  Google Scholar 

  29. Panagiotidou A, et al. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. J Orthop Res. 2013;31(12):2032–9.

    Article  PubMed  Google Scholar 

  30. Kao YY, et al. Flexural rigidity, taper angle, and contact length affect fretting of the femoral stem trunnion in Total hip arthroplasty. J Arthroplast. 2016;31(9 Suppl):254–8.

    Article  Google Scholar 

  31. Munir S, Walter WL, Walsh WR. Variations in the trunnion surface topography between different commercially available hip replacement stems. J Orthop Res. 2015;33(1):98–105.

    Article  PubMed  Google Scholar 

  32. Huet R, Sakona A, Kurtz SM. Strength and reliability of alumina ceramic femoral heads: review of design, testing, and retrieval analysis. J Mech Behav Biomed Mater. 2011;4(3):476–83.

    Article  PubMed  Google Scholar 

  33. Kocagoz SB, et al. Does taper angle clearance influence fretting and corrosion damage at the head-stem Interface? A matched cohort retrieval study. Semin Arthroplast. 2013;24(4):246–54.

    Article  Google Scholar 

  34. Werner PH, et al. Basic principles and uniform terminology for the head-neck junction in hip replacement. Hip Int. 2015;25(2):115–9.

    Article  PubMed  Google Scholar 

  35. Heckmann ND, et al. Total hip arthroplasty bearing surface trends in the United States from 2007 to 2014: the rise of ceramic on polyethylene. J Arthroplast. 2018;33(6):1757–1763 e1.

    Article  Google Scholar 

  36. Dyrkacz RM, et al. The influence of head size on corrosion and fretting behaviour at the head-neck interface of artificial hip joints. J Arthroplast. 2013;28(6):1036–40.

    Article  Google Scholar 

  37. LaHaise K, et al. Pinnacle Ultamet metal-on-metal total hip arthroplasty survivorship: average 10-year follow-up. Arthroplast Today. 2020;6(3):596–600 e1.

    Article  PubMed  PubMed Central  Google Scholar 

  38. Porter DA, et al. Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014;472(12):3963–70.

    Article  PubMed  PubMed Central  Google Scholar 

  39. Morlock M, et al. Corrosion of the head-stem taper junction-are we on the verge of an epidemic?: review article. HSS J. 2017;13(1):42–9.

    Article  PubMed  Google Scholar 

  40. Chandra A, et al. Life expectancy of modular Ti6Al4V hip implants: influence of stress and environment. J Mech Behav Biomed Mater. 2011;4(8):1990–2001.

    Article  CAS  PubMed  Google Scholar 

  41. Hoffman EE, et al. Grain boundary assisted crevice corrosion in CoCrMo alloys. Corrosion. 2016;72(11):1445–61.

    Article  CAS  Google Scholar 

  42. Ralston KD, Birbilis N. Effect of grain size on corrosion: a review. Corrosion. 2010;66(7):075005–075005-13.

    Article  Google Scholar 

  43. Rehmer A, Bishop NE, Morlock MM. Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses. Clin Biomech (Bristol, Avon). 2012;27(1):77–83.

    Article  PubMed  Google Scholar 

  44. Witt F, et al. Quantification of the contact area at the head-stem taper Interface of modular hip prostheses. PLoS One. 2015;10(8):e0135517.

    Article  PubMed  PubMed Central  Google Scholar 

  45. Jauch SY, et al. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis. J Biomech. 2011;44(9):1747–51.

    Article  CAS  PubMed  Google Scholar 

  46. Mroczkowski ML, et al. Effect of impact assembly on the fretting corrosion of modular hip tapers. J Orthop Res. 2006;24(2):271–9.

    Article  PubMed  Google Scholar 

  47. MacLeod AR, et al. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability. Bone Joint Res. 2016;5(8):338–46.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  48. Guhrs J, et al. Stem taper mismatch has a critical effect on ceramic head fracture risk in modular hip arthroplasty. Clin Biomech (Bristol, Avon). 2017;41:106–10.

    Article  PubMed  Google Scholar 

  49. Pennock AT, Schmidt AH, Bourgeault CA. Morse-type tapers: factors that may influence taper strength during total hip arthroplasty. J Arthroplast. 2002;17(6):773–8.

    Article  Google Scholar 

  50. Gilbert JL, Mehta M, Pinder B. Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length. J Biomed Mater Res B Appl Biomater. 2009;88(1):162–73.

    Article  PubMed  Google Scholar 

  51. Lavernia CJ, et al. The effects of blood and fat on Morse taper disassembly forces. Am J Orthop (Belle Mead NJ). 2009;38(4):187–90.

    PubMed  Google Scholar 

  52. Weiser MC, Lavernia CJ. Trunnionosis in total hip arthroplasty. J Bone Joint Surg. 2017;99(17):1489–501.

    Article  PubMed  Google Scholar 

  53. Donaldson FE, Coburn JC, Siegel KL. Total hip arthroplasty head-neck contact mechanics: a stochastic investigation of key parameters. J Biomech. 2014;47(7):1634–41.

    Article  PubMed  Google Scholar 

  54. Jauch SY, et al. Micromotions at the taper interface between stem and neck adapter of a bimodular hip prosthesis during activities of daily living. J Orthop Res. 2013;31(8):1165–71.

    Article  CAS  PubMed  Google Scholar 

  55. Hallab NJ, et al. Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res. 2005;23(2):384–91.

    Article  CAS  PubMed  Google Scholar 

  56. Bradberry SM, Wilkinson JM, Ferner RE. Systemic toxicity related to metal hip prostheses. Clin Toxicol (Phila). 2014;52(8):837–47.

    Article  CAS  PubMed  Google Scholar 

  57. Raju S, et al. Trunnion corrosion in metal-on-polyethylene total hip arthroplasty: a case series. J Am Acad Orthop Surg. 2017;25(2):133–9.

    Article  PubMed  Google Scholar 

  58. Plummer DR, et al. Diagnosis and management of adverse local tissue reactions secondary to corrosion at the head-neck junction in patients with metal on polyethylene bearings. J Arthroplast. 2016;31(1):264–8.

    Article  Google Scholar 

  59. Lash NJ, et al. Delayed dislocation following metal-on-polyethylene arthroplasty of the hip due to ‘silent’ trunnion corrosion. Bone Joint J. 2016;98-B(2):187–93.

    Article  CAS  PubMed  Google Scholar 

  60. Yi PH, et al. Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res. 2015;473(2):498–505.

    Article  PubMed  Google Scholar 

  61. Kwon YM. Cross-sectional imaging in evaluation of soft tissue reactions secondary to metal debris. J Arthroplast. 2014;29(4):653–6.

    Article  Google Scholar 

  62. Hauptfleisch J, et al. A MRI classification of periprosthetic soft tissue masses (pseudotumours) associated with metal-on-metal resurfacing hip arthroplasty. Skelet Radiol. 2012;41(2):149–55.

    Article  Google Scholar 

  63. Nam D, Barrack RL, Potter HG. What are the advantages and disadvantages of imaging modalities to diagnose wear-related corrosion problems? Clin Orthop Relat Res. 2014;472(12):3665–73.

    Article  PubMed  PubMed Central  Google Scholar 

  64. Garbuz DS, et al. The John Charnley award: diagnostic accuracy of MRI versus ultrasound for detecting pseudotumors in asymptomatic metal-on-metal THA. Clin Orthop Relat Res. 2014;472(2):417–23.

    Article  PubMed  Google Scholar 

  65. McGrory BJ, McKenney BR. Revision for taper corrosion at the head-neck junction: pearls and pitfalls. Curr Rev Musculoskelet Med. 2016;9(1):97–102.

    Article  PubMed  PubMed Central  Google Scholar 

  66. Goyal N, et al. Do you have to remove a corroded femoral stem? J Arthroplast. 2014;29(9 Suppl):139–42.

    Article  Google Scholar 

  67. Jennings JM, Dennis DA, Yang CC. Corrosion of the head-neck junction after total hip arthroplasty. J Am Acad Orthop Surg. 2016;24(6):349–56.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2023 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Akkaya, M., Gehrke, T., Citak, M. (2023). Trunnionosis in Total Hip Arthroplasty. In: Sharma, M. (eds) Hip Arthroplasty. Springer, Singapore. https://doi.org/10.1007/978-981-99-5517-6_35

Download citation

  • DOI: https://doi.org/10.1007/978-981-99-5517-6_35

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-99-5516-9

  • Online ISBN: 978-981-99-5517-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics