Abstract
A simple, rapid, and precise method is developed for the quantitative determination of lumefantrine (Lume) in active pharmaceutical ingredient (API). A chromatographic separation of Lume and its degradants were achieved with an X-Terra RP18, 250 × 4.6 mm, and 5 μ analytical column using buffer–acetonitrile (30:70 v/v). The buffer used in mobile phase contains 0.1 M sodium perchlorate monohydrate in double distilled water pH adjusted to 2.1 with trifluoroacetic acid. The instrumental settings are flow rate of 0.5 mL (L), column temperature at 35 °C, and detector wavelength of 235 nm using a photodiode array detector. Lume was exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analysed by the proposed method. Peak homogeneity data of Lume obtained by photodiode array detection, in the stressed sample chromatograms, demonstrated the specificity of the method for estimation in the presence of degradants. The described method shows excellent linearity over a range of 10–200 μg L−1 for Lume. The correlation coefficient is 1. The relative standard deviation of peak area for six measurements is always less than 2% between days. The proposed method was found to be suitable and accurate for quantitative determination and stability study of Lume in API.
Similar content being viewed by others
References
The Merck Index (2001) 13th edn. Merck & Co., Inc., USA
Mansor SM, Navaratnam V, Yahaya N, Nair NK, Wernsdorfer WH, Degen PH (1996) J Chromatogr B Analyt Technol Biomed Life Sci 682:321. doi:10.1016/0378-4347(96)00086-2
Zeng MY, Lu ZL, Yang SC, Zhang M, Liao J, Liu SL, Teng XH (1996) J Chromatogr B Analyt Technol Biomed Life Sci 681:299. doi:10.1016/0378-4347(95)00542-0
Annerberg A, Singtoroj T, Tipmanee P, White NJ, Day NPJ, Lindegardh N (2005) J Chromatogr B Analyt Technol Biomed Life Sci 822:330–333. doi:10.1016/j.jchromb.2005.06.022
Lindegardh N, Annerberg A, Blessborn D, Bergqvist Y, Day N, White NJ (2005) J Pharm Biomed Anal 37:1081. doi:10.1016/j.jpba.2004.07.041
Blessborn D, Romsing S, Annerberg A, Sundquist D, Bjorkman A, Lindegardh N, Bergqvist Y (2007) J Pharm Biomed Anal 45:282–287. doi:10.1016/j.jpba.2007.07.015
International conference on harmonisation: guidelines for the photostability testing of new drug substances and products, step 4, Q1B. 1996
Validation of analytical procedures: text and methodology. In: ICH harmonized tripartite guidelines Q2 (R1). November 2005
Acknowledgments
The authors are grateful to the Zuventos Pharmaceuticals Ltd. (Mumbai, India) for gift sample and to the head of the Department of Chemical Technology, Dr. Babasaheb Ambedkar, Marathwada University, Aurangabad, India for providing laboratory facility for this research work.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Patil, K.R., Rane, V.P., Sangshetti, J.N. et al. A Stability-Indicating LC Method for Lumefantrine. Chroma 69, 375–379 (2009). https://doi.org/10.1365/s10337-008-0894-x
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1365/s10337-008-0894-x