Skip to main content
Log in

A Stability-Indicating LC Method for Lumefantrine

  • Limited Short Communication
  • Published:
Chromatographia Aims and scope Submit manuscript

Abstract

A simple, rapid, and precise method is developed for the quantitative determination of lumefantrine (Lume) in active pharmaceutical ingredient (API). A chromatographic separation of Lume and its degradants were achieved with an X-Terra RP18, 250 × 4.6 mm, and 5 μ analytical column using buffer–acetonitrile (30:70 v/v). The buffer used in mobile phase contains 0.1 M sodium perchlorate monohydrate in double distilled water pH adjusted to 2.1 with trifluoroacetic acid. The instrumental settings are flow rate of 0.5 mL (L), column temperature at 35 °C, and detector wavelength of 235 nm using a photodiode array detector. Lume was exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analysed by the proposed method. Peak homogeneity data of Lume obtained by photodiode array detection, in the stressed sample chromatograms, demonstrated the specificity of the method for estimation in the presence of degradants. The described method shows excellent linearity over a range of 10–200 μg L−1 for Lume. The correlation coefficient is 1. The relative standard deviation of peak area for six measurements is always less than 2% between days. The proposed method was found to be suitable and accurate for quantitative determination and stability study of Lume in API.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. The Merck Index (2001) 13th edn. Merck & Co., Inc., USA

  2. Mansor SM, Navaratnam V, Yahaya N, Nair NK, Wernsdorfer WH, Degen PH (1996) J Chromatogr B Analyt Technol Biomed Life Sci 682:321. doi:10.1016/0378-4347(96)00086-2

    Article  CAS  Google Scholar 

  3. Zeng MY, Lu ZL, Yang SC, Zhang M, Liao J, Liu SL, Teng XH (1996) J Chromatogr B Analyt Technol Biomed Life Sci 681:299. doi:10.1016/0378-4347(95)00542-0

    Article  CAS  Google Scholar 

  4. Annerberg A, Singtoroj T, Tipmanee P, White NJ, Day NPJ, Lindegardh N (2005) J Chromatogr B Analyt Technol Biomed Life Sci 822:330–333. doi:10.1016/j.jchromb.2005.06.022

    Article  CAS  Google Scholar 

  5. Lindegardh N, Annerberg A, Blessborn D, Bergqvist Y, Day N, White NJ (2005) J Pharm Biomed Anal 37:1081. doi:10.1016/j.jpba.2004.07.041

    Article  CAS  Google Scholar 

  6. Blessborn D, Romsing S, Annerberg A, Sundquist D, Bjorkman A, Lindegardh N, Bergqvist Y (2007) J Pharm Biomed Anal 45:282–287. doi:10.1016/j.jpba.2007.07.015

    Article  CAS  Google Scholar 

  7. International conference on harmonisation: guidelines for the photostability testing of new drug substances and products, step 4, Q1B. 1996

  8. Validation of analytical procedures: text and methodology. In: ICH harmonized tripartite guidelines Q2 (R1). November 2005

Download references

Acknowledgments

The authors are grateful to the Zuventos Pharmaceuticals Ltd. (Mumbai, India) for gift sample and to the head of the Department of Chemical Technology, Dr. Babasaheb Ambedkar, Marathwada University, Aurangabad, India for providing laboratory facility for this research work.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Devanand B. Shinde.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Patil, K.R., Rane, V.P., Sangshetti, J.N. et al. A Stability-Indicating LC Method for Lumefantrine. Chroma 69, 375–379 (2009). https://doi.org/10.1365/s10337-008-0894-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1365/s10337-008-0894-x

Keywords

Navigation