Background

Cardiac implantable electronic devices (CIEDs) deliver lifesaving and transforming therapies for millions of patients worldwide every year. Globally, CIED implantation has been increasing year-on-year in many countries [1]. However, the growth in CIED implantation has coincided with a higher-than-expected rise in CIED infection [2, 3]. The reasons of the excess rise in CIED infection are many and include older CIED recipients with more co-morbidities and a larger portion of complex and revision procedures (e.g. pulse generator replacement, lead insertion and removal) [4, 5]. The current guidelines recommend complete removal (including all the leads) of any infected CIED system [3]. However, this radical treatment strategy might not always be feasible due to patient and resource factors, in which case an attempt could be made to salvage the infected CIED system [6]. Successful salvage of infected CIED system with in situ sterilisation of the contaminated hardware has been reported [7, 8].

TauroPace™ (TauroPharm GmbH, Waldbüttelbrunn, Bavaria, Germany) is an antimicrobial agent specifically developed for use during CIED procedures. Its active ingredient is taurolidine. Dissolved in an aqueous solution (which contains povidone to increase its stability), in presence of esterase and enzymes, taurolidine and cyclo-taurolidine are hydrolysed to the active compounds n-methylol-taurultam, taurultam and n-methylol-taurinamide [9, 10]. The metabolites degrade further through hydrolysis into taurine, a naturally occurring amino-sulfonic acid found in many biological tissues and secretions. In the process, 3 methylol groups are generated and these are believed to be the chemical active species responsible for taurolidine’s antimicrobial actions, which include denaturation of the pathogen cell wall and surface fimbrae or flagellate, inhibition of adherence to human epithelial and fibroblast cells, interference with biofilm formation, neutralisation of endotoxins and some exotoxins [11,12,13,14,15]. After all the antimicrobial actions have been delivered, the end-product of taurolidine metabolism, taurine, has anti-oxidant and anti-inflammatory properties and has been shown to enhance wound healing in vitro and in animal models in vivo [16,17,18]. Taurine creates an acidic local environment that further enhances the hydrolysis of taurolidine. The half-lives of the active metabolites methyl-taurultam and methylol taurinamide are 1.56 and 6 h in the presence of saccharides, peptides and glycans [19].

Case presentation

A 70-year-old male patient was implanted with a single-chamber implantable cardioverter defibrillator (ICD) in February 2012. In February 2017, his device was upgraded to an ICD capable of delivering cardiac resynchronisation therapy. The upgrade procedure was straightforward and the patient received antibiotic prophylaxis as per the implantation centre’s protocol. The patient made an uncomplicated recovery from the procedure. He had no issues with device malfunction or wound infection/skin erosion at 4 weeks and 12 weeks follow-up.

In November 2018, the patient was incidentally noticed to have purulent fluid seeping out from a fistula approximately 8 mm cranial to the lateral end of the device wound scar when assessed for toe amputation (Fig.1). The patient was re-referred back to the electrophysiology service. On inspection, the inflammation appeared mild and localised around the device wound scar. Swabs from the discharging punctum grew methicillin-resistant Staphylococcus epidermidis sensitive to linezolid. Repeated blood cultures were consistently negative for bacterial growth. Trans-oesophageal echocardiography showed no vegetations on the intracardiac portions of the leads. The patient declined complete ICD explantation with lead extraction but would agree to a less invasive device salvage procedure. As a result, the latter treatment strategy was adopted.

Fig. 1
figure 1

Picture of surgical site showing discharging punctum just cranial to the lateral end of the previous incision scar

Pre-procedure, empirical antibiotic therapy was started with cefuroxim. It was changed and the patient received 7 continuous days of intravenous linezolid as per the advice from Microbiology. During the procedure, an elliptical island of skin around the punctum was excised. The incision was then extended into the original ICD wound scar at both ends. The ICD pulse generator was liberated from the encasing fibrous subcutaneous tissues, extracted out of the device pocket, detached from the leads, cleaned of any obvious adherent debris and then immersed in TauroPace™ (TauroPharm GmbH, Bavaria, Germany). The sutures holding the anchor sleeves and leads in place were cut and removed. The anchor sleeves were removed. Capsulectomy was performed by electric cautery with simultaneous haemostasis. The debrided device pocket was irrigated with TauroPace™. The accessible segments of the leads were wiped with swabs soaked with TauroPace™. The connector pins of the leads were wiped with TauroPace™ swabs before being plugged back into the ports on the old ICD pulse generator. The torque wrench was dipped in TauroPace™ before engaging with the seals covering the set screws. A subpectoral pocket was prepared and irrigated with TauroPace™ and the pulse generator and leads were positioned within. The wound was closed. Another 20 cc of TauroPace™ was injected directly into the subcutaneous tissues around the wound (not into the pocket!).

The device wound showed some mild inflammation the next day but that rapidly settled. Repeat blood culture was negative for bacterial growth. The patient recovered well from the procedure and was discharged. The patient was followed up continuously for 33 months from his device salvage in November 2018 till his death from causes unrelated to his ICD or infection in August 2021 (Fig. 2). During that time, the patient suffered no recurrence of ICD infection or skin erosion.

Fig. 2
figure 2

Timeline

Conclusions

Despite categorical guideline recommendation of complete system explantation for treatment of CIED infection [3], lead extraction requires special equipment and expertise, may not be readily available or acceptable to the patient, and is associated with a risk (however small) of very serious complications (e.g. cardiac avulsion, vascular avulsion, haemothorax and cardiac tamponade) that may result in emergency open chest surgery or even death [20]. CIED salvage is an attractive alternative management strategy if it could be made more effective in “eradicating” infection, in the sense of no recurrence of overt clinical infection even if dormant bacteria colonisation remains [21]. CIED salvage may have been successful in anecdotal reports [7, 8], but was not consistently effective in larger series [6]. The antimicrobial agents which have been used for pocket irrigation and in situ hardware sterilisation include diluted povidone-iodine, diluted hydrogen peroxide, diluted alcohol and antibiotic solutions. TauroPace™ is an alternative antimicrobial agent that has been successfully used to salvage left ventricular assist device driveline infection [22]. Apart from antimicrobial actions, the wound healing enhancement properties of taurolidine (taurine) when locally applied (directly injected into the subcutaneous tissues around the pocket in this case) is an additional bonus [17, 18]. This first report of TauroPace™’s use in successful salvage CIED infection provides a proof-of-concept and foundation for future research.