Abstract
A highly efficient fluorescent sensor (S-DAC) was easily created by functionalizing the SBA-15 surface with N-(2-Aminoethyl)-3-Aminopropyltrimethoxysilane followed by the covalent attachment of 7-diethylamino 3-acetyl coumarin (DAC). This chemosensor (S-DAC) demonstrates selective and sensitive recognition of Fe3+ and Hg2+ in water-based solutions, with detection limits of 0.28 × 10–9 M and 0.2 × 10–9 M for Hg2+ and Fe3+, respectively. The sensor’s fluorescence characteristics were examined in the presence of various metal ions, revealing a decrease in fluorescence intensity upon adding Fe3+ or Hg2+ ions at an emission wavelength of 400 nm. This sensor was also able to detect ferric and mercury ions in spinach and tuna fish. The quenching mechanism of S-DAC was investigated using UV–vis spectroscopy, which confirmed a static-type mechanism for fluorescence quenching. Moreovre, the decrease in fluorescence intensity caused by mercury and ferric ions can be reversed using trisodium citrate dihydrate and EDTA as masking agents, respectively. As a result, a circuit logic gate was designed using Hg2+, Fe3+, trisodium citrate dihydrate, and EDTA as inputs and the quenched fluorescence emission as the output.
Graphic abstract
![](http://media.springernature.com/lw685/springer-static/image/art%3A10.1186%2Fs11671-024-04013-9/MediaObjects/11671_2024_4013_Figa_HTML.png)
Similar content being viewed by others
Avoid common mistakes on your manuscript.
1 Introduction
Today, there is evidence that living organisms' water environment and food cycle are contaminated with non-biodegradable hazardous heavy metal ions. Therefore, due to their biological effects on living systems, the identification of these pollutants has received wide attention from researchers [1,2,3]. Although mercury metal exists naturally in the environment, such as air, water, soil, and organisms are exposed to harmless low levels, critical doses are associated with adverse physical and neurotoxic side effects in living organisms [4,5,6,7,8]. Among hazardous compounds, mercury ranks as the sixth most toxic element [9]. While all types of Mercury, including elemental (Hg0) and ionic (Hg+, Hg2+), are toxic and bioaccumulated, methyl mercury tends to build up more significantly than other forms. Bacteria can transform elemental (Hg0) and ionic Mercury (Hg+, Hg2+) into methyl mercury, which then enters the food chain of water-dwelling organisms and bioaccumulates over time [10,11,12].
Monitoring and researching pollution in water-dwelling organisms like fish and sea mammals, along with the subsequent harm, results in worldwide expenses amounting to billions [13].
Accumulation of both organic and inorganic forms Mercury species in the human body can lead to a variety of diseases related to the brain and nervous system, such as irritability, nervousness, changes in personality, sensory issues like vision problems and deafness, and cognitive disorders. It can also cause Minamata disease, and in severe cases, it could be fatal [6,7,8, 14,15,16,17].
Fe3+, as one of the most abundant heavy metals in the Earth’s crust, plays an essential role in various biochemical processes at the cellular level in most organisms [18,19,20]. The role of Fe3+ in these biochemical processes includes DNA and RNA replication, facilitating the oxygen transfer from lungs to tissues via heme, regulation of cellular electron transactions, and different bio-syntheses such as enzymatic reactions, and cellular metabolism [21,22,23]. However, the level of Fe3+ in the organism is crucial, with lower and higher levels linked to different diseases and even life-threatening conditions. For instance, insufficient Fe3+ is associated with anemia, diabetes, cancer, hemochromatosis, dysfunctions in the liver and kidney, and neurogenerative diseases such as Parkinson's and Alzheimer's [20, 24,25,26,27,28,29,30]. On the other hand, an elevated concentration of Fe3+ is linked to the creation of free radicals, which can harm tissues and escalate the oxidation of cellular components like lipids and proteins [29,30,31]. The scientific community has extensively researched the monitoring and detection of Fe3+ using various sensors. A range of methods have been employed to detect heavy metals [32,33,34,35,36]. On the other hand, the fluorescent sensors have been considerably developed due to their low costs, easy operation, high sensitivity, selectivity, and rapid response [37,38,39]. Fluorescent sensors based on organic molecules are among the most common fluorescent sensors [40].
Although most of these sensors need organic solvents for optimal performance and are not soluble in H2O, their use in entirely aqueous media is limited. Therefore, there is a pressing need to design and produce a new class of fluorescent sensors to overcome these limitations [41,42,43,44].
Recently, organic–inorganic hybrid sensors have been developed based on fixing fluorophore groups onto the surface of inorganic nanomaterial substrates. Among, Nanoporous silica materials, SBA-15 is particularly notable due to its unique features such as hydrothermal stability, uniform pores structure, thick walls, high specific surface area, and biocompatibility. Additionally, the optically transparency and non-fluorescence nature of SBA-15 make it an suitable candidate for grafting with fluorophores to create fluorescent sensors [45,46,47]. Herein,
a highly efficient fluorescent sensor (S-DAC) is easily created by functionalizing the SBA-15 surface with N-(2-Aminoethyl)-3-Aminopropyltrimethoxysilane followed by the covalent attachment of 7-diethylamino 3-acetyl coumarin (DAC).
3 Surface modification of SBA-Pr-NH-Et-NH2 with 7-diethylamino 3-acetyl coumarin (S-DAC)
Firstly, the 7-diethylamino-3-acetyl coumarin compound (5 mmol) was dissolved in EtOH (25 ml), added to the suspension of SBA-Pr-NH-Et-NH2 (1 g) in EtOH (25 ml), and refluxed for 24 h. After the filteration of reaction mixture, the filterate was washed with EtOH and then EtOAc to obtain the final product of S-DAC, which was charechterized by different methods.
3.1 Fluorescence measurements
For all fluorescence experiments, 0.005 g of S-DAC in 100 ml of deionized water was dispersed using an ultrasonic bath. Suitable nitrate salts were dissolved in distilled water to prepare stock solutions of metal ions (1 × 10–2 mol L−1). In addition, sodium and potassium salts were employed to prepare the anionic stock solutions (1 × 10–2 mol L−1). 2 mL of the dispersed solution and 50 µL of various metal ions (10−2 M) were used to record the fluorescence spectrum. For the competition tests, besides the target ion, other ions as interfering agents with a ratio of 1:5 were added to the 2 mL of the dispersed solution. Furthermore, for the titration measurements, different amounts of the target ion (0–200 µL, 1 × 10–6 mol L−1) were added to the 2 mL of S-DAC dispersion. The photoluminescence measurements were recorded with the emission wavelength at about 480 nm, while the excitation wavelength was tuned at 400 nm.
4 Results and discussion
This study presents a fluorescent switchable sensor based on a coumarin derivative-functionalized SBA-15 for selective recognition of Hg2+ and Fe3+ in the aqueous environment and real sample. The design of this type of mesopore-based sensor has shown several results. Firstly, it increases the surface area, allowing more fluorophores to be loaded. Secondly, it reduces the detection limit or increases its sensitivity. The chemosensor of S-DAC comprises 7-diethylamino 3-acetyl coumarin (DAC) units as a fluorophore and N-(2-Aminoethyl)-3-Aminopropyltrimethoxysilane as a linker, on a mesoporous substrate. It was evaluated its photoluminescence performance in the presence of various metal ions. The obtained results revealed that the fluorescence intensity of S-DAC was remarkably quenched by Hg2+ and Fe3+ ions compared to other cations. Further investigation showed that trisodium citrate dihydrate and EDTA could reverse the emission intensity of mercury and ferric ions, respectively, and a logic gate circuit was provided. Finally, this potential chemosensor can be applied in real samples such as spinach and tuna fish.
4.1 Functionalization of SBA-Pr-NH-Et-NH2 with coumarin derivatives
Coumarin derivative-functionalized nanoporous silica (S-DAC) was easily created by functionalizing the SBA-15 surface with N-(2-Aminoethyl)-3-Aminopropyltrimethoxysilane, followed by the reaction with 7-diethylamino 3-acetyl coumarin (DAC), which was prepared by the.reaction of 4-diethylamino salicylic aldehyde, acetyl acetoacetate and piperidine in EtOH as depicted in Scheme 1.
4.2 Structural characterization of S-DAC
FT-IR spectroscopy was utilized to confirm the successful immobilization of functional groups onto the pore walls of SBA-15. The FT-IR spectra of SBA-15, SBA-Pr-NH-Et-NH2, and S-DAC are presented in Fig. 1. For all samples, the bands located at around 457 cm−1, 1806 cm−1, and 1085 cm−1 are related to bending vibrations and symmetric and asymmetric stretching vibrations of siloxane (Si–O–Si) groups, respectively [49]. The band at around 973 cm−1 is attributed to the stretching vibrations of the silanol groups (Si–OH) [51]. The broad peak around 3439 cm−1 is assigned to the stretching vibrations of the –OH groups belonging to H2O and silanol groups [49, 51]. The band at around 1635 cm−1 is related to the physically absorbed H2O molecules [52]. The intensity of the peaks associated with silanol groups (973 cm−1 and 3439 cm−1) decreases after grafting with the linker. The appearance of peaks at around 2850–2965 cm−1 is related to the aliphatic chain’s stretching vibrations of methylene groups [53]. A new band at about 1578 cm−1 is observed, which is probably related to the bending vibration of NH2 [51]. In addition, in the spectrum of S-DAC, the strong peak at around 1616 cm−1 can be assigned to stretching vibrations of the carbonyl group. Also, two bands at about 1361 cm−1 and 1506 cm−1 are attributed to the ring C=C and C=N stretching vibrations, respectively [54]. Therefore, the FT-IR results suggest the successful attachment of the fluorophore onto the SBA-15 surface.
The Low-angle XRD patterns of SBA-Pr-NH-Et-NH2 and S-DAC were shown in Fig. 2i. Both samples exhibit three characteristic diffraction patterns related to nanoporous compounds. The intense diffraction near 2θ = 1° diffracted from the (100) plane, accompanied by two weaker peaks near 2θ = 2° diffracted from the (110) and (200) planes, confirms the long-range periodic order and two-dimensional hexagonal mesostructure of SBA-15 with P6mm space group [55]. The similarity of the diffraction patterns in both samples suggests that the original structure of SBA-15 is preserved after the surface modification. The decrease in X-ray diffraction intensity after functionalization is due to the attachment of organic moieties onto the pore walls of SBA-15, which causes a decline in relatively lower long-range order and crystallinity [56]. These results demonstrate the successful surface modification and preservation of the mesostructure after functionalization.
The N2 adsorption–desorption isotherms of SBA-15 and S-DAC are presented in Fig. 2ii. The type IV standard IUPAC isotherm with an H1-type hysteresis loop, corresponding to the ordered structure of mesoporous materials, is demonstrated for SBA-15 and S-DAC [57]. The observation of similar characteristics in the isotherm of SBA-15 and S-DAC, but with a lower height of the hysteresis loop and a lower level of gas adsorption in S-DAC, proves that the SBA-15 structure is preserved and the pore walls of S-DAC were not filled or closed after the modification steps. As observed in the inset table of Fig. 2ii, grafting organic moieties onto the walls of SBA-15 channels causes a decrease in the specific surface area (SBET), average pore diameter (dP), and pore volume (VP) of S-DAC.
The thermogravimetric analysis (TGA) curves of SBA-Pr-NH-Et-NH2 and S-DAC were provided in Fig. 3. These curves were used to estimate the approximate amount of the organic moieties grafted to the pore walls of SBA-15. In both cases, the initial mass loss (12%) below 150 °C is attributed to the desorption of the physically adsorbed H2O molecules and other volatiles entrapped within the SBA-15 pore channels. Moreover, the subsequent significant mass loss between 150 and 650 °C can be associated with the degradation of grafted organic compounds. The weight loss above 650 °C can be assigned to the dehydroxylation of the Si–OH groups from the SBA-15 framework. The total weight loss for SBA-Pr-NH-Et-NH2 and S-DAC was estimated to be about 43% and 50%, respectively. A difference of about 7% between the two curves was attributed to the amount of grafted various organic moieties. As a result, the amount of the attached organic moieties onto the pore channels of SBA-Pr-NH-Et-NH2 and S-DAC was estimated at approximately 1.7 and 0.85 mmol g−1, respectively.
The transmission electron microscopy (TEM) images of the S-DAC was demondstrated in Fig. 4, which was exhibited the well-ordered 2D hexagonal rod-shaped mesopore of the S-DAC. This result confirmed that after the grafting of organic molecules, the ordered mesoporous structure of the S-DAC was well maintained.
The Zeta potential of samples in the presence and absence of analytes and particle size distribution of S-DAC can be shown in Table 1.
4.3 Fluorescence studies
4.3.1 Fluorescence response of S-DAC to metal ions
To evaluate the selectivity of the S-DAC fluorescent sensor in water, its fluorescence response was investigated towards a wide variety of metal ions, such as Ca2+, Zn2+, Co2+, Cd2+, Ni2+, Pb2+, Ba2+, K+, Fe3+, Hg2+, Cu2+, Li+, etc. As shown in Fig. 5, the fluorescence spectrum of the free S-DAC (3 ml, 0.05 g L−1) was recorded at an excitation wavelength of 400 nm and an emission wavelength of 482 nm. Then, the emission spectrum of the fluorescent sensor was recorded in the presence of various metal ions (50 µL, 10–2 M). The fluorescence emission of the S-DAC is significantly quenched upon adding Fe3+ and Hg2+ ions. In contrast, introducing other metal ions exhibits no notable spectral change or variation of emission intensity. Therefore, the S-DAC fluorescent sensor exhibited excellent selectivity towards Fe3+ and Hg2+ ions in aqueous solutions.
4.3.2 Selectivity study of S-DAC for Fe3+ and Hg2+ ions
In addition, in the presence of other interfering cations, Hg2+ and Fe3+ ions still bring about similar fluorescence changes. Competition tests were carried out to prove the selectivity of the S-DAC fluorescent sensor towards Hg2+ and Fe3+ ions. In each experiment, the fluorescence emission intensity was recorded after adding the fluorescent sensor to the mixture of target ions and other interfering ions at a ratio of 1:5. The results show that other cations have no significant effect on the emission intensity of the S-DAC in the presence of target ions, making it a suitable and selective fluorescent sensor for detecting Hg2+ and Fe3+ ions in aqueous media (Fig. 6(i) and (ii)).
(i) Fluorescence emission of S-DAC upon addition of various aqueous metal ions (5 eq.) in the absence and presence of Hg2+ (1 eq.) with λex: 400 nm and λem: 480 nm and (ii) Fluorescence emission of S-DAC upon addition of various aqueous metal ions (5 eq.) in the absence and presence of Fe3+ (1 eq.) with λex: 400 nm and λem: 480 nm
4.3.3 Titration experiments
To evaluate the relation between fluorescence emission intensity and the concentration of Hg2+ and Fe3+ ions, titration studies were performed by different concentrations of Hg2+ and Fe3+ ions in the range of (0–200) × 10–6 M. The fluorescence emission intensity gradually declined upon adding target metal ions as demonstrated in Fig. 7(i) and (ii). Furthermore, the linear calibration curve was plotted for I0/I versus [Hg2+] and [Fe3+] (inset of (Fig. 7(i) and (ii)) and virtually indicated linearity between the emission intensity of S-DAC and the concentration of Hg2+ and Fe3+. The DL = 3σ/m equation was also used to estimate the limit of detection (LOD) for S-DAC, where σ is the standard deviation intercept from the calibration curve, and m is the slope of the calibration curve. As a result, the detection limit was calculated as 0.28 × 10–9 mol L−1 for Hg2+ and 0.2 × 10–9 mol. L−1 for Fe3+ analytes. In addition, the linear concentration range was calculated as (0.49 × 10–9–4.39 × 10–9 mol L−1) and (0.99 × 10–9–5.21 × 10–9 mol L−1) for Hg2+ and Fe3+, respectively. The results of LOD reveal intense sensitivity of S-DAC toward Hg2+ and Fe3+ ions as an analyte. The Stern–Volmer Quenching constant was calculated as 0.14204 for Hg2+ and 0.13298 for Fe3+ analytes.
4.3.4 Quenching mechanism of S-DAC to Fe3+ and Hg2+ ions
Fe3+ ions likely cause the fluorescence quenching of S-DAC due to their paramagnetic nature. The ferric ion has five unpaired electrons in the d orbitals, which significantly facilitates the transfer of electrons or energy, leading to the emission quenching of the fluorescent sensor. This transfer between Fe3+ and the fluorescent sensor prohibits the intersystem crossing, resulting in the non-fluorescence complex [58]. The fluorescence quenching upon adding the Hg2+ ion occurred probably due to the heavy atom effect [59]. The rotating orbiting electrons on the Hg2+ ion create a magnetic moment that can be coupled with the magnetic moment generated by the fluorophore electron spin, enabling the electrons to dissipate energy and relaxation to the ground state without emitting any light. The receptor Schiff-base in the S-DAC fluorescent sensor has three coordination sites: the ethylene diamine nitrogen atom, the carbonyl group's oxygen atom, and the imine group’s nitrogen atom. Hg2+ ions have a larger radius than other competitive cations, such as first-row transition metal cations, and also have a more substantial bond capability to the N atoms in the receptor than alkali, alkaline earth metal cations. These results in a stronger coordination bond of Hg2+ ions with the Schiff-base receptor. This process indicates that the S-DAC fluorescent sensor is a highly selective fluorescent sensor for Hg2+ in the water medium. The detailed quenching mechanism of the S-DAC fluorescent sensor in the presence of Hg2+ and Fe3+ ions is described in Scheme 2.
To determine the mechanism, The UV–Vis spectra of S-DAC in the presence and absence of iron and mercury ions were investigated in the absence and presence of the analytes (Fig. 8i). The distinguished differences in the adsorption spectra of the samples confirm the static emission quenching mechanism, which is due to the formation of a complex between the fluorescent sensor and Fe3+ and Hg2+ ions [60]. To evaluate the feasibility of S-DAC as a fluorescent sensor in real samples, two samples of spinach and tuna fish were used to determine Fe3+ and Hg2+ ions, respectively. As explained in San et al. work [61], the digestion method was used to prepare the real samples. The fluorescence emissions of the fluorescent sensor were recorded in the absence and presence of the prepared samples. The measured fluorescence spectra of the S-DAC fluorescent chemosensor before and after adding the prepared samples was shown in Fig. 8ii. Therefore, S-DAC can be used as a fluorescent sensor to determine trace target ions in real samples, especially foodstuffs like spinach and tuna fish.
4.3.5 Logic gate and turn off–on behavior of S-DAC
Further studies have revealed that adding trisodium citrate dihydrate (Cit) to the mixture of S-DAC and Hg2+ results in a significant enhancement in fluorescence emission intensity and the return to the initial emission state of the S-DAC. Without the presence of Hg2+ ions, no significant effect on the fluorescence emission of the S-DAC was observed. This phenomenon is likely due to the strong interaction between Hg2+ ions and trisodium citrate dihydrate, which can release the S-DAC fluorescent sensor by breaking the complex between the fluorescent sensor and Hg2+ ions, increasing the fluorescence emission intensity. The fluorescence emission intensity of the S-DAC–Fe3+ ions complex can be inverted by adding ethylenediaminetetraacetic acid (EDTA4Na). In contrast, the fluorescence emission of S-DAC has no response to (EDTA4Na) alone (Fig. 9). Similarly, as with Hg2+ and trisodium citrate dihydrate, the strong bonds between Fe3+ and EDTA could explain this observation. Accordingly, the logic circuit and truth table were designed with the trisodium citrate dihydrate, EDTA, Fe3+, and Hg2+ ions as input and fluorescence emission value as output, based on a standard expression called Sum-Of-Products. Regarding the output, ‘1’ and ‘0’ were called the emission quenching and fluorescence emission, respectively. The corresponding truth table and logic circuit diagram can be observed in Table 2 and (Fig. 10).
4.3.6 Analysis
In addition, the performance of this chemosensor was compared to the others previously reported ones as listed in Table 3. It was demonstrated that this prepared chemosensor (S-DAC) releaved a higher sensitivity in detecting metal ions (Fe3+ and Hg2+) in aqueous media.
5 Conclusion
A fluorescent sensor based on a coumarin derivative-functionalized nanoporous silica with high selectivity and sensitivity can be used for the detection of Fe3+ and Hg2+ ions in aqueous media with detection limits of 0.28 × 10–9 M and 0.2 × 10–9 M for Hg2+ and Fe3+, respectively. The fluorescence detection of target ions has occurred in the presence of other cations without any interference. The calibration curve indicates linearity between the emission intensity of S-DAC and the concentration of Hg2+ and Fe3+. As the concentration of the target ion increases and the complex forms between the sensor and the target ion, there is a gradual decrease in fluorescence emission. The quenching in fluorescence intensity with Hg2+ and Fe3+ ions can be returned to the original emission state, and enhancement in fluorescence emission of the S-DAC with trisodium citrate dihydrate and EDTA as masking agents, respectively. Accordingly, a sum-of-product logic gate was designed with the trisodium citrate dihydrate, EDTA, Hg2+, and Fe3+ as input and quenched fluorescence emission as the output. In addition, this sensor is used to detect Hg2+ and Fe3+ ions in real samples such as spinach and tuna fish.
Data availability
The data supporting this study's findings are available from the corresponding author upon reasonable request.
Code availability
Not applicable.
References
Ge F, Li MM, Ye H, Zhao BX. Effective removal of heavy metal ions Cd2+, Zn2+, Pb2+, Cu2+ from aqueous solution by polymer-modified magnetic nanoparticles. J Hazard Mater. 2012;211:366–72.
Nolan EM, Lippard SJ. Tools and tactics for the optical detection of mercuric ion. Chem Rev. 2008;108(9):3443–80.
Nwaichi EO, Dhankher OP. Heavy metals contaminated environments and the road map with phytoremediation. J Environ Prot. 2016;7(01):41–51.
Leopold K, Foulkes M, Worsfold P. Methods for the determination and speciation of mercury in natural waters—a review. Anal Chim Acta. 2010;663(2):127–38.
Moreno FN, Anderson CW, Stewart RB, Robinson BH. Mercury volatilization and phytoextraction from base-metal mine tailings. Environ Pollut. 2005;136(2):341–52.
Dey N. A simple strategy for the visual detection and discrimination of Hg2+ and CH3Hg+ species using fluorescent nanoaggregates. Dalton Trans. 2021;50(36):12563–9.
Yourston L, Dhoqina P, Marshall N, Mahmud R, Kuether E, Krasnoslobodtsev AV. Hg2+ detection with rational design of DNA-templated fluorescent silver nanoclusters. Processes. 2021;9(10):1699.
Shellaiah M, Rajan YC, Balu P, Murugan A. A pyrene-based Schiff base probe for selective fluorescence turn-on detection of Hg2+ ions with live cell application. New J Chem. 2015;39(4):2523–31.
Von Burg R. Inorganic mercury. J Appl Toxicol. 1995;15(6):483–93.
Benoit J, Fitzgerald W, Damman A. The biogeochemistry of an ombrotrophic bog: evaluation of use as an archive of atmospheric mercury deposition. Environ Res. 1998;78(2):118–33.
El-Safty SA, Ismail AA, Matsunaga H, Mizukami F. Optical nanosensor design with uniform pore geometry and large particle morphology. Chem A Eur J. 2007;13(33):9245–55.
World Health Organization, Guidelines for drinking-water quality. Vol. 1. 2004: World Health Organization.
Ros-Lis JV, Marcos MD, Mártinez-Máñez R, Rurack K, Soto J. A regenerative chemodosimeter based on metal-induced dye formation for the highly selective and sensitive optical determination of Hg2+ ions. Angew Chem Int Ed. 2005;44(28):4405–7.
Clarkson TW, Magos L. The toxicology of mercury and its chemical compounds. Crit Rev Toxicol. 2006;36(8):609–62.
Grandjean P, Weihe P, White RF, Debes F. Cognitive performance of children prenatally exposed to “safe” levels of methylmercury. Environ Res. 1998;77(2):165–72.
Zahir F, Rizwi SJ, Haq SK, Khan RH. Low dose mercury toxicity and human health. Environ Toxicol Pharmacol. 2005;20(2):351–60.
Shellaiah M, Simon T, Venkatesan P, Sun KW, Ko FH, Wu SP. Cysteamine-modified diamond nanoparticles applied in cellular imaging and Hg2+ ions detection. Appl Surf Sci. 2019;465:340–50.
Kailasa SK, Ha S, Baek SH, Kim S, Kwak K, Park TJ. Tuning of carbon dots emission colour for sensing of Fe3+ ion and bioimaging applications. Mater Sci Eng C. 2019;98:834–42.
Shi L, Zhao B, Li X, Zhang G, Zhang Y, Dong C, Shuang S. Eco-friendly synthesis of nitrogen-doped carbon nanodots from wool for multicolour cell imaging, patterning, and biosensing. Sens Actuators B Chem. 2016;235:316–24.
Pan C, Wang K, Ji S, Wang H, Li Z, He H, Huo Y. Schiff base derived Fe3+-selective fluorescence turn-off chemosensors based on triphenylamine and indole: synthesis, properties and application in living cells. RSC Adv. 2017;7(57):36007–14.
Andjelković M, Van Camp J, De Meulenaer B, Depaemelaere G, Socaciu C, Verloo M, Verhe R. Iron-chelation properties of phenolic acids bearing catechol and galloyl groups. Food Chem. 2006;98(1):23–31.
Ganz T. Hepcidin, a key regulator of iron metabolism and mediator of anemia of inflammation. Blood. 2003;102(3):783–8.
Rouault TA. The role of iron regulatory proteins in mammalian iron homeostasis and disease. Nat Chem Biol. 2006;2(8):406–14.
Kalinowski DS, Richardson DR. Future of toxicology iron chelators and differing modes of action and toxicity: the changing face of iron chelation therapy. Chem Res Toxicol. 2007;20(5):715–20.
Silvestri L, Camaschella C. A potential pathogenetic role of iron in Alzheimer’s disease. J Cell Mol Med. 2008;12(5a):1548–50.
Berg D, Gerlach M, Youdim MBH, Double KL, Zecca L, Riederer P, Becker G. Brain iron pathways and their relevance to Parkinson’s disease. J Neurochem. 2001;79(2):225–36.
Duvigneau JC, Piskernik C, Haindl S, Kloesch B, Hartl RT, Hüttemann M, Lee I, Ebel T, Moldzio R, Gemeiner M, Redl H, Kozlov AV. A novel endotoxin-induced pathway: upregulation of heme oxygenase 1, accumulation of free iron, and free iron-mediated mitochondrial dysfunction. Lab Investig. 2008;88(1):70–7.
Wu T, Sempos CT, Freudenheim JL, Muti P, Smit E. Serum iron, copper and zinc concentrations and risk of cancer mortality in US adults. Ann Epidemiol. 2004;14(3):195–201.
Qi C-X, Xu YB, Li H, Chen XB, Xu L, Liu B. A highly sensitive and selective turn-off fluorescence sensor for Fe3+ detection based on a terbium metal-organic framework. J Solid State Chem. 2021;294: 121835.
Shellaiah M, Thirumalaivasan N, Aazaad B, Awasthi K, Sun KW, Wu SP, Lin MC, Ohta N. Novel rhodamine probe for colorimetric and fluorescent detection of Fe3+ ions in aqueous media with cellular imaging. Spectrochim Acta Part A Mol Biomol Spectrosc. 2020;242: 118757.
Jayaweera S, Yin K, Hu X, Ng WJ. Facile preparation of fluorescent carbon dots for label-free detection of Fe3+. J Photochem Photobiol A Chem. 2019;370:156–63.
Gomes DMC, Segundo MA, Lima JLFC, Rangel AO. Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system. Talanta. 2005;66(3):703–11.
Nolan MA, Kounaves SP. Microfabricated array of iridium microdisks as a substrate for direct determination of Cu2+ or Hg2+ using square-wave anodic stripping voltammetry. Anal Chem. 1999;71(16):3567–73.
Ohashi A, Ito H, Kanai C, Imura H, Ohashi K. Cloud point extraction of iron (III) and vanadium (V) using 8-quinolinol derivatives and Triton X-100 and determination of 10–7 mol dm−3 level iron (III) in riverine water reference by a graphite furnace atomic absorption spectroscopy. Talanta. 2005;65(2):525–30.
Vanhoe H, Vandecasteele C, Versieck J, Dams R. Determination of iron, cobalt, copper, zinc, rubidium, molybdenum, and cesium in human serum by inductively coupled plasma mass spectrometry. Anal Chem. 1989;61(17):1851–7.
Zhao L, Li J, Sui D, Wang Y. Highly selective fluorescence chemosensors based on functionalized SBA-15 for detection of Ag+ in aqueous media. Sens Actuators B Chem. 2017;242:1043–9.
Li H-G, Yang Z-Y, Qin D-D. A new Schiff-base type selective fluorescent chemosensor for Cu2+. Inorg Chem Commun. 2009;12(6):494–7.
Mandal S, Banerjee A, Lohar S, Chattopadhyay A, Sarkar B, Mukhopadhyay SK, Sahana A, Das D. Selective sensing of Hg2+ using rhodamine–thiophene conjugate: red light emission and visual detection of intracellular Hg2+ at nanomolar level. J Hazard Mater. 2013;261:198–205.
Zhang Y, Li B. A multifunctional selective fluorescent chemosensor for detection of Ga3+, In3+ and Fe3+ in different solvents. J Mol Struct. 2022;1250: 131461.
Du J, Hu M, Fan J, Peng X. Fluorescent chemodosimeters using “mild” chemical events for the detection of small anions and cations in biological and environmental media. Chem Soc Rev. 2012;41(12):4511–35.
Chang Y-J, Hung PJ, Wan CF, Wu AT. A highly selective fluorescence turn-on and reversible sensor for Al3+ ion. Inorg Chem Commun. 2014;39:122–5.
Neupane LN, Park JY, Park JH, Lee KH. Turn-on fluorescent chemosensor based on an amino acid for Pb (II) and Hg (II) ions in aqueous solutions and role of tryptophan for sensing. Org Lett. 2013;15(2):254–7.
Yuan A, Zheng C, Zhang Z, Yang L, Liu C, Wang H. A novel quinazolinone derivative as fluorescence quenching off-on sensor for high selectivity of Fe3+. J Fluoresc. 2014;24(2):557–61.
Zhang Y, Wang G, Zhang J. Study on a highly selective fluorescent chemosensor for Fe3+ based on 1, 3, 4-oxadiazole and phosphonic acid. Sens Actuators B Chem. 2014;200:259–68.
Hoffmann F, Cornelius M, Morell J, Fröba M. Silica-based mesoporousorganic–inorganic hybrid materials. Angew Chem Int Ed. 2006;45(20):3216–51.
Mousavi Z, Ghasemi JB, MohammadiZiarani G, Saidi M, Badiei A. Dihydropyrano quinoline derivatives functionalized nanoporous silica as novel fluorescence sensor for Fe3+ in aqueous solutions (aq). J Mol Struct. 2022;1265:133408.
Zarabadi-Poor P, Badiei A, Yousefi AA, Barroso-Flores J. Selective optical sensing of Hg (II) in aqueous media by H-Acid/SBA-15: a combined experimental and theoretical study. J Phys Chem C. 2013;117(18):9281–9.
Bahrami Z, Badiei A, MohammadiZiarani G. Thiol-functionalized mesoporous silica as nanocarriers for anticancer drug delivery. Int J Bio-Inorg Hybr Nanomater. 2015;4(3):121–8.
Zhang Y, Cao X, Sun J, Wu G, Wang J, Zhang D. Synthesis of pyridyl Schiff base functionalized SBA-15 mesoporous silica for the removal of Cu (II) and Pb (II) from aqueous solution. J Sol-Gel Sci Technol. 2020;94:658–70.
Bhattacharyya A, Makhal SC, Guchhait N. Evaluating the merit of a diethylamino coumarin derived thiosemicarbazone as an intramolecular charge transfer probe: efficient Zn (II) mediated emission swing from green to yellow. Photochem Photobiol Sci. 2019;18:2031–41.
Wang W, Wu G, Zhu T, Yang Y, Zhang Y. Synthesis of-thiazole Schiff base modified SBA-15 mesoporous silica for selective Pb (II) adsorption. J Taiwan Inst Chem Eng. 2021;125:349–59.
Zheng L, Yang Y, Zhang Y, Zhu T, Wang X. Functionalization of SBA-15 mesoporous silica with bis-schiff base for the selective removal of Pb (II) from water. J Solid State Chem. 2021;301: 122320.
Bahalkeh F, Mehrabian RZ, Ebadi M. Removal of Brilliant Red dye (Brilliant Red E-4BA) from wastewater using novel Chitosan/SBA-15 nanofiber. Int J Biol Macromol. 2020;164:818–25.
Zhang Y, Wu G, Yang Y, Sun J, Zhang D. Preparation of SBA-15 mesoporous silica grafted with bis-salicylaldehyde Schiff base for uptake of Pb (II) and Cu (II) from water. J Sol-Gel Sci Technol. 2021;98:170–82.
Li Y-J, Yan B. Lanthanide (Eu3+, Tb3+)/β-diketone modified mesoporous SBA-15/organic polymer hybrids: chemically bonded construction, physical characterization, and photophysical properties. Inorg Chem. 2009;48(17):8276–85.
Zhao D, Huo Q, Feng J, Chmelka BF, Stucky GD. Nonionic triblock and star diblock copolymer and oligomeric surfactant syntheses of highly ordered, hydrothermally stable, mesoporous silica structures. J Am Chem Soc. 1998;120(24):6024–36.
Dong Z, Dong Z, Ren J, Jin J, Wang P, Jiang J, Li R, Ma J. A quinoline group modified SBA-15 INHIBIT logic gate with [Cu2+ and Zn2+] or [Cu2+ and Cd2+] as inputs. Microporous Mesoporous Mater. 2010;135(1–3):170–7.
Xiang Y, Tong A. A new rhodamine-based chemosensor exhibiting selective FeIII-amplified fluorescence. Org Lett. 2006;8(8):1549–52.
Fitch A. Lead analysis: past and present. Crit Rev Anal Chem. 1998;28(3):267–345.
Tanwar AS, Parui R, Garai R, Chanu MA, Iyer PK. Dual “Static and Dynamic” fluorescence quenching mechanisms based detection of TNT via a cationic conjugated polymer. ACS Meas Sci Au. 2021;2(1):23–30.
Sun D-H, Waters JK, Mawhinney TP. Determination of thirteen common elements in food samples by inductively coupled plasma atomic emission spectrometry: comparison of five digestion methods. J AOAC Int. 2000;83(5):1218–24.
Afshani J, Badiei A, Karimi M, Lashgari N, Mohammadi Ziarani G. A Schiff base-grafted nanoporous silica material as a reversible optical probe for Hg2+ ion in water. Appl Organomet Chem. 2017;31(12): e3856.
Badiei A, Yadavi M, Karimi M. A novel diethyl 2-(9-fluorenyl) malonate functionlized SBA-15 for selective optical sensing of Iron. J Nanostruct. 2019;9(1):146–53.
Fahmi MRG, Fajar AT, Roslan N, Yuliati L, Fadlan A, Santoso M, Lintang HO. Fluorescence study of 5-nitroisatin Schiff base immobilized on SBA-15 for sensing Fe3+. Open Chem. 2019;17(1):438–47.
Acknowledgements
The authors thank the research council of the University of Tehran for their support.
Funding
“The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.”
Author information
Authors and Affiliations
Contributions
Zahra Mousavi: Data curation, Writing an original draft. Jahan B. Ghasemi: Formal analysis, Ghodsi Mohammadi Ziarani: Editing, Methodology, Conceptualization. Shahnaz Rahimi: Validation. Alireza Badiei: Review & editing, Project administration.
Corresponding authors
Ethics declarations
Competing interests
“The authors have no relevant financial or non-financial interests to disclose.”
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Mousavi, Z., Ghasemi, J.B., Mohammadi Ziarani, G. et al. Coumarin derivative-functionalized nanoporous silica as an on–off fluorescent sensor for detecting Fe3+ and Hg2+ ions: a circuit logic gate. Discover Nano 19, 70 (2024). https://doi.org/10.1186/s11671-024-04013-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s11671-024-04013-9