Skip to main content
Log in

Improvement of precision spectrophotometric method with internal reference and its application to analysis of plutonium solutions

  • Published:
Radiochemistry Aims and scope

Abstract

A spectrophotometric precision method with internal reference [1, 2] was applied to analysis of straight Pu solutions for certifying Pu reference materials and for studying the PuO2 solubility in the framework of developing methods for accounting and control of nuclear materials. In the context of the activities mainly concerned with certification of reference materials, a two-channel spectrophotomer and the corresponding technique were further improved in order to decrease the error of the method. This allowed the random component of the relative error of the method to be decreased from 0.1 to 0.04% at the confidence level p = 0.95 and the number of degrees of freedom f = 25. The fixed component of the error of the method was studied in relation to impurities of U, Np and corrosion products of structural materials. Also, the extent of Pu oxidation during sample preparation was studied as influenced by the fluoride ion. The revealed lack of such influence within the limits of the study indicates that the method is suitable for analysis of Pu in mixed solutions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Stepanov, A.V., Nikitina, S.A., Karasev, V.T., et al., Radiokhimiya, 2002, vol. 44, no. 2, pp. 165–169.

    Google Scholar 

  2. Stepanov, A.V., Nikitina, S.A., Karasev, V.T., et al., Tr. Radievogo Inst. im V.G. Khlopina, 2003, vol. 10, pp. 50–58.

    Google Scholar 

  3. Doerffel, K. und Geyer, R., Analytikum. Methoden der analytischen Chemie und ihre theoretischen Grundlagen, Leipzig: Deutscher Verlag für Grundstoffindustrie, 1971. Translated under the title Rukovodstvo po analiticheskoi khimii, Moscow: Mir, 1975, p. 17.

    Google Scholar 

  4. Grigor’eva, M.G., Nikitina, S.A., Pevtsova, E.V., et al., Radiokhimiya, 2003, vol. 45, no. 4, pp. 351–356.

    Google Scholar 

  5. The Chemistry of the Actinide Elements, Katz, J.J., Seaborg, G.T., and Morss, L.R., Eds., London: Chapman and Hall, 1986. Translated under the title Khimya aktinidov, Katz, J., Seaborg, G., and Morss, L., Eds., Moscow: Mir, 1999; vol. 2, p. 333; vol. 3, pp. 407.

    Google Scholar 

  6. Penkin, M.V., Stepanov, A.V., Belyaev, B.N., et al., Khlopin Radium Institute Activity in the Field of Development of the Nuclear Reference Materials for Safeguard Purposes, Proc. INMM 40th Annual Meet., Phoenix (Arizona), July 1999.

  7. Stepanov, A.V. et al., Prigotovlenie i analiz rastvora plutoniya-240 (Preparation and Analysis of a Plutonium-240 Solution1), Report of the Khlopin Radium Inst., 1995, St. Petersburg, no. 2485.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Deceased.

Original Russian Text © A.V. Stepanov, D.A. Stepanov, S.A. Nikitina, T.D. Gogoleva, M.G. Grigor’eva, L.S. Bulyanitsa, Yu.A. Panteleev, M.V. Pen’kin, E.V. Pevtsova, V.D. Domkin, 2006, published in Radiokhimiya, 2006, Vol. 48, No. 2, pp. 179–184.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stepanov, A.V., Stepanov, D.A., Nikitina, S.A. et al. Improvement of precision spectrophotometric method with internal reference and its application to analysis of plutonium solutions. Radiochemistry 48, 198–203 (2006). https://doi.org/10.1134/S1066362206020196

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1066362206020196

PACS numbers

Navigation