Abstract
The application of miniaturized homogeneous liquid-liquid extraction (MHLLE) technique as a simple, inexpensive, quick and efficiency clean up method has been evaluated for determination of diazinon, alachlor, chlorpyrifos and butachlor in cow milk samples. Methanol was used as extraction solvent for the extraction of analytes from cow milk samples and then, methanol phase was extracted and cleaned up by MHLLE method. In this method, butyl acetate was added to methanol phase and after addition of water, butyl acetate was separated from methanol phase and injected to the GC/TSD instrument. The concentration ranges were from 1.0–1000.0 ng/mL for diazinon and chlorpyrifos and from 5.0–1000.0 ng/mL for alachlor and butachlor. The limits of detection were 0.4, 1.6, 0.3 and 1.4 ng/mL for diazinon, alachlor, chlorpyrifos and butachlor, respectively. Finally, the extraction method was successfully applied to the analysis of raw cow milk samples.
Similar content being viewed by others
References
Sharma, D., Nagpal, A., Pakade, Y.B., and Katnoria, J.K., Talanta, 2010, vol. 82, no. 4, p. 1077.
Pagliuca, G., Gazzotti, T., Zironi, E., and Sticca, P., J. Chromatogr. A, 2005, vol. 1071, nos. 1–2, p. 67.
Dagnac, T., Chao, M.G., Pulleiro, P., Jares, C.G., and Llompart, M., J. Chromatogr. A, 2009, vol. 1216, no. 18, p. 3702.
Frenich, A.G., Vidal, J.L.M., Sicilia, A.D.C., Rodríguez, M.J.G., and Bolanos, P.P., Anal. Chim. Acta, 2006, vol. 558, nos. 1–2, p. 42.
Novakova, L. and Vlckova, H., Anal. Chim. Acta, 2009, vol. 656, nos. 1–2, p. 8.
Zhao, E., Zhao, W., Han, L., Jiang, S., and Zhou, Z., J. Chromatogr. A, 2007, vol. 1175, no. 1, p. 137.
Pedersen-Bjergaard, S. and Rasmussen, K.E., J. Chromatogr. B, 2005, vol. 817, no. 1, p. 3.
Hassan, J., Farahani, A., Shamsipur, M., and Damerchili, F., J. Hazard. Mater, 2010, vol. 184, nos. 1–3, p. 869.
Shamsipur, M. and Hassan, J., J. Chromatogr. A, 2010, vol. 1217, no. 30, p. 4877.
Hassan, J. and Habibi, S., Chromatographia, 2011, vol. 73, nos. 9–10, p. 1005.
Fumani, N.S., Hassan, J., and Yousefi, S.R., J. Sep. Sci., 2011, vol. 34, no. 11, p. 1333.
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
Rights and permissions
About this article
Cite this article
Hassan, J. Low density miniaturized homogeneous liquid-liquid extraction: a new high throughput sample preparation technique for the determination of polar pesticides in cow milk. J Anal Chem 69, 851–855 (2014). https://doi.org/10.1134/S106193481409007X
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S106193481409007X