An upgraded ion source for a mass spectrometer

  • General Experimental Techniques
  • Published:
Instruments and Experimental Techniques Aims and scope Submit manuscript

Abstract

A model analysis of ion sources for dynamic mass spectrometers was performed, and the design of an upgraded ion source, which substantially reduces the ion energy spread, allows optimization of the zone of ion extraction from the source, and provides a high sensitivity of the instrument in the operation with low-energy ionizing electrons (down to threshold energies), was developed. Methodological techniques that allow one to analyze and calculate numerical model variants of ion sources of various designs using the SIMION 3D 7.0 program were developed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Dawson, P.H., Quadrupole Mass Spectrometer and Its Applications, New York: Elsevier, 1976.

    Google Scholar 

  2. Mallard, G. and Linstrom, P.J., NIST Standard Reference Database, 2000, vol. 69; http://www.web-book.nist.gov

  3. Monopol’nyi mass-spektrometr MX 7304A (MX-7304A Monopole Mass Spectrometer Description and Service Instruction), Sumy: SELMI, 2003.

  4. Slobodenyuk, G.I., Kvadrupol’nye mass-spektrometry (Quadrupole Mass Spectrometers), Moscow: Atomizdat, 1975.

    Google Scholar 

  5. Baturin, V.A., Eremin, S.A., and Pustovoitov, S.A., Tech. Phys., 2007, vol. 52, pp. 770–775.

    Article  Google Scholar 

  6. Baturin, V.A., Eremin, S.A., and Pustovoitov, S.A., Vopr. At. Nauki Tekhn., Ser. Plazm. Elektr. Nov. Met. Uskor., 2006, no. 5, p. 222.

  7. SIMION 7.0 (Version 7 SIMION3D 7.0, SIMION™); http://www.simion.com

  8. Agafonova, A.S., Surkov, V.A., and Fishkova, T.Ya., Tech. Phys., 2009, vol. 54, pp. 312–316.

    Article  Google Scholar 

  9. Agafonova, A.S., Surkov, V.A., Zavilopulo, A.N., and Mironets, E.A., Ukraine Patent 58673, 2010.

  10. Zavilopulo, A.N., Shpenik, O.B., Snegurskii, A.V., et al., Tech. Phys. Lett., 2005, vol. 31, pp. 785–788.

    Article  Google Scholar 

  11. Zavilopulo, A.N., Surkov, V.A., and Shpenik, O.B., Anal. Chim. Acta, 2006, vol. 573-574, p. 427.

    Article  Google Scholar 

  12. Wannier, G.H., Phys. Rev., 1953, vol. 90, p. 817.

    Article  ADS  MATH  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. N. Zavilopulo.

Additional information

Original Russian Text © A.N. Zavilopulo, E.A. Mironets, A.S. Agafonova, 2012, published in Pribory i Tekhnika Eksperimenta, 2012, No. 1, pp. 73–79.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zavilopulo, A.N., Mironets, E.A. & Agafonova, A.S. An upgraded ion source for a mass spectrometer. Instrum Exp Tech 55, 65–71 (2012). https://doi.org/10.1134/S0020441211060315

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020441211060315

Keywords

Navigation