Abstract
A microbore electrospray (ESI) injection system has been adapted to our 9.4-tesla ESI FT-ICR mass spectrometer, greatly enhancing the stability and sensitivity of the system. Spray was generated from micro-ESI needles made from sharply tapered, polished fused silica capillaries of 25 to 50 µm inner diameter. Micro-ESI permits low-level sample analysis by constant infusion at sub-µL/min flow rate over a wide range of solvent conditions in both positive- and negative-ion mode. The system is flexible and allows rapid conversion to allow routine LC/MS analysis on low-level mixtures presented in biological media. LC/MS analyses were accomplished by replacing micro-ESI needles with capillaries packed with reverse phase retention media to permit analyte concentration and purification prior to analysis (micro-ESI/LC). A unique nano-flow LC pumping system was developed, capable of producing a true unsplit solvent gradient at flow rates below 1 µL/min. The micro-ESI/LC FT-ICR system produces mass spectra from a mixture of three neuroactive peptides at a concentration of 500 amol/µL (5 fmol each total loaded) in biological salts with baseline separation, signal-to-noise ratio of >10:1 and mass resolving power >5000. These results represent a reduction in detection limit by a factor of ∼2 × 106 over the best previously published LC/FT-ICR MS data.
Similar content being viewed by others
References
Fenn, J.B.; Mann, M.; Meng, C.K.; Wong, S.F. Mass Spectrom. Rev. 1990, 9, 37–70.
Fenn, J.B.; Mann, M.; Meng, C.K.; Wong, S.F.; Whitehouse, C.M. Science 1989, 246, 64–71.
Mann, M. Org. Mass Spectrom. 1990, 25, 575–587.
Kebarle, P.; Tang, L. Anal. Chem. 1993, 65, 972A-986A.
Emmett, M.R.; Caprioli, R.M. J. Am. Soc. Mass Spectrom. 1994, 5, 605–613.
Kennedy, R.T.; Jorgenson, J.W. Anal. Chem. 1989, 61, 1128–1135.
Mosely, M.A.; Deterling, L.J.; Tomer, K.B.; Jorgenson, J.W. Anal. Chem. 1991, 63, 1467–1473.
Emmett, M.R.; Andren, P.E.; Caprioli, R.M. J. Neurosci. Methods 1995, 62, 141–147.
Wilm, M.S.; Matthias, M. Int. J. Mass Spectrom. Ion Processes 1994, 136, 167–180.
Andren, P.E.; Emmett, M.R.; Caprioli, R.M. J. Am. Soc. Mass Spectrom. 1994, 5, 867–869.
Wilm, M.; Mann, M. Anal. Chem. 1996, 68, 1–8.
Valeskovic, G.A.; Kelleher, N.L.; Little, D.P.; Aaseruud, D.J.; MacLafferty, F.W. Anal. Chem. 1995, 67, 3802–3805.
Valaskovic, G.A.; Kelleher, N.K.; McLafferty, F.W. Science 1996, 273, 1199–1202.
Hofstadler, S.A.; Severs, J.C.; Smith, R.D.; Swanek, F.D.; Ewing, A.G. Rapid Commun. Mass Spectrom. 1996, 10, 919–922.
Henry, K.D.; Williams, E.R.; Wang, B.-H.; McLafferty, F.W.; Shabanowitz, J.; Hunt, D.F. Proc. Natl. Acad. Sci. USA 1989, 86, 9075–9078.
Senko, M.W.; Hendrickson, C.L.; Pasa-Tolic, L.; Marto, J.A.; White, F.M.; Guan, S.; Marshall, A.G. Rapid Commun. Mass Spectrom. 1996, 10, 1824–1828.
Senko, M.W.; Hendrickson, C.L.; Emmett, M.R.; Shi, S.D.-H.; Marshall, A.G. J. Am. Soc. Mass Spectrom. 1997, 8, 970–976.
Marshall, A.G.; Wang, T.-C.L.; Ricca, T.L. J. Am. Chem. Soc. 1985, 107, 7893–7897.
Guan, S.; Marshall, A.G. Int. J. Mass Spectrom. Ion Processes 1996, 157/158, 5–37.
Woodlin, R.L.; Bomse, D.S.; Beauchamp, J.L. J. Am. Chem. Soc. 1978, 100, 3248–3250.
Little, D.P.; Speir, J.P.; Senko, M.W.; O’Connor, P.B.; McLafferty, F.W. Anal. Chem. 1994, 66, 2809–2815.
Beu, S.C.; Laude, D.A., Jr. Int. J. Mass Spectrom. Ion Processes 1992, 112, 215–230.
Chowdhury, S.K.; Katta, V.; Chait, B.T. Rapid Commun. Mass Spectrom. 1990, 4, 81–87.
Tomlinson, A.J.; Benson, L.M.; Jameson, S.; Johnson, D.H.; Naylor, S. J. Am. Soc. Mass Spectrom. 1997, 8, 15–24.
Valaskovic, G.A.; Kelleher, N.L.; Little, D.P.; Aaserud, D.J.; McLafferty, F.W. Anal. Chem. 1995, 67, 3802.
Valaskovic, G.A.; McLafferty, F.W. J. Am. Soc. Mass Spectrom. 1996, 7, 1270–1272.
Bateman, K.P.; White, R.L.; Thibault, P. Rapid Commun. Mass Spectrom. 1997, 11, 307–315.
Stacey, C.C.; Kruppa, G.H.; Watson, C.H.; Wronka, J.; Laukien, F.H.; Banks, J.F.; Whitehouse, C.M. Rapid Commun. Mass Spectrom. 1994, 8, 513–516.
Limbach, P.A.; Grosshans, P.B.; Marshall, A.G. Anal. Chem. 1993, 65, 135–140.
Hofstadler, S.A.; Swanek, F.D.; Gale, D.C.; Ewing, A.G.; Smith, R.D. Anal. Chem. 1995, 67, 1477–1480.
Kurian, E.; Prendergast, F.G.; Tomlinson, A.J.; Holmes, M.W.; Naylor, S. J. Am. Soc. Mass Spectrom. 1997, 8, 8–14.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Emmett, M.R., White, F.M., Hendrickson, C.L. et al. Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis. J Am Soc Mass Spectrom 9, 333–340 (1998). https://doi.org/10.1016/S1044-0305(97)00287-0
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1016/S1044-0305(97)00287-0