1 Introduction

Since the development of the world tantalum(Ta) industry in the 1920s [1], Ta has been continuously developed in the application field due to its high melting point (up to 2995 °C), good chemical stability, corrosion resistance and high density (16.68 g/cm3), widely used in electronics, chemical industry, aviation and weapon systems [2]. In the 1940s, pure Ta was first applied in medical treatment, and its stable biological characteristics also made Ta play an important role on medical treatment, including Ta wire for suture in surgical incision, Ta stent implants for vascular stenosis, Ta nails in early osteonecrosis of the thigh bone, Ta rods for supporting bone defect and porous tantalum trabecular metal (PTTM) used in joint and spinal surgery [3,4,5,6,7,8], which demonstrate good results.

The medical application of Ta is closely related to its biocompatibility. At present, the evaluation of biocompatibility of biomaterials mainly involves compliance with the requirements stipulated by the International Organization for Standardization (ISO) 10993 and National Standard GB/T16886, through a series of experiments—in vitro and in vivo. In vitro experiments, such as cytology, protein adsorption, hematology, and molecular biology experiments, can help to understand the relationship between biomaterials and tissue cells. On the other hand, in vivo experiments assisting in analyzing whether the biological behavior of biomaterial is compatible with the dynamic environment of the human body, involving tests such as systemic toxicity, immunology, subcutaneous, and bone-implant test. The researchers can choose these experimental methods according to their purpose, a series of experimental evaluations will determine whether the material is biosecurity and functional, that is to say, the material does not have a toxic effect on the human body and does not cause host heterogenic recognition reaction. At the same time, biomaterials are required to exercise their corresponding functions in specific applications, not to be rejected and destroyed, to maintain their original physical, chemical, mechanical and biological properties, and to form a good combination with the host for a long time finally.

2 Physicochemical properties of Ta and its advantages in medical applications

The traditional bone implant materials mainly include stainless steel (SS), cobalt-based alloy and titanium(Ti) alloy [9]. SS has good mechanical strength and corrosion resistance, but it will also be corroded in a specific environment in the body, also, added elements such as Cr and V in SS have certain metal toxicity. Cobalt-based alloy (CoCrMo alloy, CoCrNiMo alloy) is a kind of material widely used in the clinic, it has high fatigue strength, tensile strength, and excellent corrosion resistance, it is mainly used for replacement of bone joint prosthesis, such as knee joint and hip joint replacement prosthesis. Although cobalt-based alloy materials have good clinical effects, there are problems such as high elastic modulus, low friction characteristics, and potential toxicity of Co, Cr, and other metals [10]. Therefore, it is not suitable to make scaffold materials with guiding bone tissue growth. Ti alloy has good corrosion resistance, biocompatibility and has a large density and elastic modulus, which is widely used in medical biomaterials implanted devices manufacture [11]. However, Ti and its alloys have limited internal life, high activity, easy oxidation, and difficult processing. It is found that Ta has the elastic modulus and biocompatibility matching with human bone tissue, and can meet the requirements of bone tissue substitute materials [12]. Heiner et al. [13] found that Ta has a high bending strength. The Ta-based metal biological material can provide effective support for tissue growth due to good durability and corrosion resistance after being implanted in the living tissue, and it is a permanent biological medical material implant with good biocompatibility [14]. Yuan et al. found that Ta and Niobium(Nb) alloys have better biocompatibility than Ti alloys in organisms and can better meet the requirements of biomaterials [15]. we [16, 17] applied Ta to the preparation of dental materials and repairation of human hard tissue defects in the early stage, carried out a series of studies, and made a good breakthrough. At the same time, using 3D printing technology to prepare Ta dental crown and selective laser sintering (SLS) to prepare dental implants, obtaining accurate and rapid processing methods, see Figs. 1 and 2.

Fig. 1
figure 1

3D printing of Ta alloy dental crown

Fig. 2
figure 2

The implant on the right in the picture is 3D printing of tantalum–niobium alloy dental implant primitive form; The dental implant on the left is the commonly used Ti alloy in clinic

3 Corrosion resistance of Ta and mechanism of cell damage induced by metal ions

3.1 Ta metal has a stable passivation oxide film

The excellent corrosion resistance of biomaterials is a necessary condition for implantation into the human body, which has an important influence on the properties of implantable materials. The primary factor related to corrosion resistance is the formation of surface passivation oxide film, which can hinder the release of metal ions from the substrate, thus preventing its adverse reaction to tissue cells. No matter what kind of metal has corrosion tendency in thermodynamics, these passivation films will minimize corrosion. Table 1 lists the composition and properties of passivation films on different metals and alloys surface and the release of metal ions in different liquid environments.

Table 1 Composition, the stability of passivation films and release of metal ions on different metals under different conditions

It can be seen from the table that the chemical composition, stability, and compactness of these metal materials affect the release of metal ions under different conditions in vitro, and then affecting the biological function of the materials. X-ray photoelectron spectroscopy (XPS) and spectral measurements can be used to analyze the chemical composition of the oxide layer on the metal surface, the semi-maximum value of the oxygen signal can be used to estimate the thickness of the oxide layer on the surface of the sample [19]. Many references have proved that the passivation oxide film on Ta surface is very stable and has high corrosion resistance, and no corrosion signs have been found in physiological solution in vitro [12, 18, 19]. The results show that the Ta oxide thin films prepared in the oxidation atmosphere are in a stable + 5 valence state, However, the phase stability of Ta2O5 is also related to different crystal forms, and the B phase structure composed of deformed octahedral is stable dynamically [36, 37]. Many studies have added Ta2O5 to other materials or prepared them into thin films to improve the biological properties of the materials. For example, the addition of Ta pentoxide to polyether ether ketone (PEEK) has also been found to improve surface roughness, hydrophilicity, surface energy and protein absorption of PEEK/Ta2O5 composites [38]. Ta2O5 nanotube film displays good cellular compatibility with rabbit bone marrow mesenchymal stem cells (rBMSCs) and promotes the expression of the osteogenic genes [39]. It was found that the corrosion resistance of Ti decreased when the concentration of fluoride was high and the acid PH exposed to fluorine ions for a long time, when the PH was 4.5 and the mass fraction of NaF was 0.3 wt%, the detected Ti content was 0.6–3.4 ug/g. When 0.6–1.0 wt%NaF was contained, the Ti content increased significantly to 25–74 ug/g [23]. Other studies have shown that the corrosion resistance of industrial pure Ti(CP) and Ti6Al4V in artificial saliva containing 227 ppm and 12300 ppm F-decreases, CP Ti degrades due to pitting corrosion, Ti6Al4V has general corrosion and microcracks [26]. Also, the corrosion resistance of Ti in other liquid solutions is excellent. Semi-conductive or non-conductive oxide protective layers are formed on both Ta and Ti surfaces to prevent electronic exchange, thus preventing redox reactions on the surface [40]. And the corrosion resistance of the Ni is poor, the stability of the surface film NiO is low, and a large amount of Ni ions can be released in a short time [27, 28]. In most cases, the surface of SS and Cobalt–Chromium-based alloy forms a Chrome-rich oxide film, Cr2O3 has high corrosion resistance, which can protect the matrix from corrosion to a certain extent, However, in some other cases, such as the co-presence of hydrogen peroxide and albumin, the corrosion of SS can be accelerated, surface oxidation layer exists as corrosion products. The composition of oxide film Cobalt–Chromium alloy formed in a solution is also related to the potential. With the increase of potential, Cr(III) can be converted into Cr(VI), Co(II) to Co(III) [32, 33]. Therefore, as the potential increases, the composition of oxide film on the metal surface tends to change to a higher price to achieve stability. In a word, in terms of the protective properties of the passivation film, Ta has a very stable passivation oxide film, which can protect the substrate from corrosion to the maximum extent.

3.2 Electrochemical corrosion behavior characterizes the corrosion resistance of Ta

The corrosion resistance of the implantation can be characterized by electrochemical corrosion behavior, such as open circuit potential (OCP), potentiodynamic polarization test, electrochemical impedance spectroscopy (EIS) and so on, the test results of these indexes are closely related to the corrosion resistance of implanted metal materials. Studies have shown that in the revised simulated body fluid (r-SBF), the EIS measurement results show that the curvature radius of the capacitor ring of pure Ta is greater than Nb–60Ta–2Zr and pure Nb, indicating that pure Ta has a high polarization resistance (RP), and the passivation film grown on the surface has a stronger protective effect, the OCP measurements value moved to the positive side, where anodic dissolution occurred and an oxide film was formed [19]. Breakdown potential is the lowest potential for pitting/gap corrosion initiation and propagation, the measurement results show that the breakdown potential of 316L SS and l605 Cobalt–Chromium alloy wire is 1.03 v and 0.43 v respectively, even though the potential of pure Ta reaches 1.6 V, there is no local corrosion, which indicates that pure Ta has a high resistance to pitting corrosion [41]. Zitter et al. measured the current density of metals in saline with a stable rapid redox system, the results also showed that Ta had the lowest value, while SS and Cobalt alloy showed the highest current density [40]. The higher the RP value, the lower the corrosion current density (Icorr), and the better the corrosion resistance of the metal. Bermudez [42] studies have shown that Ta also has very good corrosion resistance in a strong acid environment (the stability second only to the surface oxide layer), compared with Ti and SS implant materials at the same time, there are no obvious changes in weight or toughness. In simulated body fluid (SBF), Ta films formed by substrate bias of − 100 V and − 200 V are mainly a mixture of β phase and a few α phases [18], it has been shown that β-Ta (Metastable tetrahedral) has higher hardness and good contact damage resistance, while α-Ta (body-centered cubic) is more plastic [43,44,45], so the Ta membrane is stable. A high amount of Ta (> 6%) added into the alloy can make the Ta2O5 structure on the surface of MoTa alloy more compact, reducing the gap between cations, and improving the corrosion resistance [46]. The characterization of electrochemical corrosion behavior further confirms the stability and high resistance to pitting corrosion of Ta oxide films in different liquid environments.

3.3 Different metal ions can induce cell damage

Once the amount of metal ions released by corrosion under different conditions exceeds the tolerance limit of cell tissue, a series of pro-inflammatory reactions will be triggered. These metal ions released by corrosion induce the cells to produce reactive oxygen species (ROS), which then initiate a series of signal transduction processes. The process of different metal ions inducing cells to produce pro-inflammatory mediators is related to Toll-like Receptor 4 (TLR4), p 38 mitogen-activated protein kinase and nuclear factor pathways [47,48,49], it can be said that oxidative stress leads to the generation of ROS, which is a key stimulant to activate these pathways. A kind of metal ion can activate a variety of intracellular signaling pathways to mediate the release of cytokines, promote local inflammatory responses, and initiate mitochondrial-mediated apoptosis. Figure 3 illustrates the specific mechanism of ROS production induced by metal ions with iron ions as an example. Fe3+ first binds to transferrin (Tf) in the blood and then recognized and bound by transporter receptors (TfR) on the surface of the cell, Fe3+ is released into the cytoplasm in the form of the endosome, after that, a series of redox reactions led to the production of ROS, which leads to oxidative stress [50, 51]. ① reaction is considered to be a chemical reaction called Fenton reaction, which catalyzes the conversion of hydrogen peroxide (H2O2) to active hydroxyl radical (HO) [52]. ② Metal ions also reduce the activities of antioxidant enzymes such as superoxide dismutase, catalase, and glutathione peroxidase, increasing lipid peroxidation, reducing the ability of cells to eliminate free radicals, significantly increasing the oxidative stress of mitochondria and the level of protein carbonylation, thus further damaging the antioxidant capacity of cells [53, 54]. Studies have shown that Co(II), Ni(II) and Cr(III) can significantly reduce cell vitality and cause pathological changes such as cell contraction, shedding, vacuole and swelling, apoptotic cells increased mostly in Co(II) exposure, and cell necrosis was predominant in Ni(II) exposure [53,54,55,56]. Co(II) can significantly reduce the movement ability of macrophages and inhibit cell migration by RhoA down-regulation and cytoskeleton reorganization, which is still happened by the emergence of ROS [57]. Ni ions gradually accumulated in cells also affect the ability of bone morphogenetic protein (BMP-2) to induce alkaline phosphatase (ALP) formation [58, 59]. Some studies have shown that compared with Nitinol, the surface layer rich in Ti or Ta can significantly reduce the formation of ROS and longevity protein free radicals [60]. Qiao et al. found that among the concentrations of metal ions causing DNA damage in vitro, Cr(III), Fe(II) and Al(III) were 50 μM, while Ni(II) 10uM could cause DNA damage, so different metal ions with the same concentration had different toxic effects on cells [61]. The size of the wear particles of biomaterials is also related to the amount of ROS produced. Co nanoparticles (CoNPs) and Co(II) can significantly reduce cell vitality, while Co (II) has a weak induction effect on cell ROS production [62]. Thus, Nanoparticles (below 100 nm) have a greater potential for surface-cell interaction than micron-sized particles, theoretically leading to dose-dependent inflammation [63, 64]. The positive LC3 points, the high expression LC3-II and the ultrastructure of autophagy vesicles were observed by confocal microscopy, Western blotting and transmission electron microscopy, which confirmed the autophagy of Ta-NPs in promoting cell proliferation, this effect is important for cells to overcome adverse conditions and maintain physiological balance. This is limited to Ta-NPs concentrations that occur below the autophagy threshold(10 μg/ml, 20 μg/ml) [65]. If the concentration of Ta-NPs continues to increase and eventually exceeds the autophagy threshold, cell viability may decline linearly. Studies have shown that Ta-NPs begins to induce a decrease in cell viability at a concentration of 25 g/ml [66]. So the increased concentration of metal ions in the body is one of the causes of implant failure, Ta’s excellent corrosion resistance can minimize this adverse effect.

Fig. 3
figure 3

The specific mechanism of ROS production induced by metal ions with iron ions as an example [50,51,52,53,54]

4 Ta has excellent biocompatibility

4.1 Cytological experiment

Methods to evaluate the biocompatibility of different biomaterials in vitro involve the effects of materials on cell growth and proliferation. Cell types commonly used for studying cytotoxicity during in vitro experiments on metal implants include bone marrow mesenchymal stem cells (BMMSCs), osteoblasts, bone cells, fibroblasts, and other normal tissue cells, and leukocytes, etc., which increase quantitatively during inflammation in the body. Figure 4 shows a pattern of adhesion and morphological changes of fibroblasts on the Ta surface. Although Ta is bioinert, it exhibits excellent cellular compatibility. Cell remodeling is a necessary condition for cell adhesion and extracellular matrix formation, cells can express proteins to modify the surface, and cells can also adapt to the attached surface, changes in the cytoskeleton are closely related to cell remodeling, and the two complement each other [67]. The cell volume was increased by 50% observed by an atomic force microscope (AFM) when the mouse MC3T3-E1 pre-osteoblasts were exposed to the Ta substrate [68]. Modin et al. confirmed by cryo-SEM that the average diffusion area of MC3T3-E1 cells on Cr was only two-thirds of that of Ta [69]. Tang et al. observed the morphology and actin skeleton of hBMSCs on the surface of porous Ta coating prepared by vacuum plasma spraying (VPS) under an electron microscope and confocal microscopy, the results showed that the hBMSCs on Ta coating had different cytoskeletal tension and flat expansion shape, while the Ti coating showed contraction shape [70]. Mikhail et al. showed that Ta and Ti coating on Nitinol alloy formed a fused monolayer after 5 days of cell culture, indicating that Ta and Ti coating surface was conducive to cell diffusion [61]. In the early adhesion, the fibroblast actin skeleton was closely wrapped around the nucleus, gradually, the cell morphology changed to polygon, and actin concentrated in the leading edge of the cell over time, and then gradually formed actin fiber [67]. Some scholars have observed by the fluorescence microscope that the 4 h average area of human mesenchymal stem cells (HMSCs) attached to the Ta surface increased by 33% and 23% compared with the surface of Cr and Ti, respectively, showing a stronger tensile appearance. Compared with Ta, Ti cell proliferation was significantly increased after 4 days, the average cell area of Cr decreased and the proliferation ability was poor [71]. This is slightly different from the results of Hofstetter et al.’s in vitro study on the metal coating, which prepared 6 kinds of coatings by plasma vapor deposition (PVD), among them, Ta is more effective than Ti in cell proliferation, and similarly, Cr has the lowest surface proliferation [72]. From these results, it can be seen that the biocompatibility of Cr is poor. The difference between Ti and Ta may be due to differences in early osteogenic differentiation ability, Ta can promote early bone integration. Cell adhesion and proliferation play a very important role in the whole cycle of cells and subsequently promote the differentiation of cells and the formation of the extracellular matrix.

Fig. 4
figure 4

Take fibroblasts as an example, simulating the morphological changes of cells on Ta surface

4.2 Molecular biology experiment

In addition to the important role of cell adhesion and proliferation in the initial stage of cell growth, the osseointegration capability of Ta as a bone implant material needs to be evaluated. The morphological expansion, proliferation, and differentiation of cells on the surface of biomaterials are related to the expression of a series of genes and proteins after the cells are stimulated by the surface of the biomaterial. Some studies have shown that Ta has better osteogenic differentiation ability than Ti in prosthesis and implant coating, and the structural and chemical properties of the material surface have a significant influence on cell behavior, as well as the subsequent bone induction and integration [70,71,72]. The expression of ALP is a marker of osteoblast differentiation, expression analysis of bone-related genes is also used to evaluate the osteogenic differentiation ability of cells, for example, type I collagen COL1A1 is the main component of the extracellular matrix of bone cells, and BGLAP is a marker of late osteoblast differentiation [72]. Runx 2 has been identified as a key transcription factor regulating osteogenesis and a controlling gene in the early stage of osteogenesis differentiation. OPN is an indicator of medium stage differentiation and osteocalcin (OC) is an indicator of late-stage differentiation [73]. Mengmeng et al. studied the effect of intrinsic chemical properties of the Ta and Ti surface (except the effect of surface roughness) on the osteogenic properties of BMSCS. The results showed that mRNA expression levels of integrin a5, integrin β1, Runx 2, and downstream effector factors ALP, OCN and COL-I on the Ta surface were 1.5–2.1 times higher than those on Ti surface [74]. Integrin plays an important role in the formation of focal adhesion complex, mediating intracellular signal transduction and regulating cell differentiation [74]. The osteogenic effect of cells on the Ta surface is better than that on Ti surface cells, which may be due to the stronger ability of the surface to trigger integrin.

4.3 Protein adsorption experiment

Metal implants exposed to complex physiological conditions come into contact with a variety of high molecular weight organic compounds, especially proteins. When a protein-containing liquid touches a foreign body, it immediately coats the surface with an adsorbed protein. There is no effective way to elucidate the effect of the adsorption of this protein on the metal implant, which may be related to the type and concentration of the protein and the nature of the implant material [75]. On the one hand, protein adsorption is an important step for early cell adhesion and diffusion, which is closely related to the life of the implanted device. As a thin film on the metal surface, it also protects the passive film from wear and corrosion on many repaired artificial joints. On the other hand, the metal ions are combined with the protein to form a colloidal metal–organic compound, and the migration of the complex from the interface increases the dissolution rate. Besides, it may be related to thrombosis and foreign body reaction [75, 76]. Therefore, the effect of protein adsorption on metal implants depends on the specific related environment. Proteins commonly used as indicators of cellular biocompatibility include extracellular protein bovine serum albumin (BSA), fibrinogen, lysozyme (LYS), collagen, etc. Figure 5 shows the adsorption of different types of proteins on the Ta surface. Currently, due to Ta’s high density and other characteristics, it is not suitable for large-scale implantation. Therefore, Ta coating and Ta2O5 thin film are the main forms of research on Ta in vitro. For Ta, topographic surface design, especially nanoscale chemistry and morphology, is conducive to protein adsorption, which will promote cell proliferation and differentiation, especially the enhancement of bone regeneration ability [77, 78]. Quartz crystal microbalance (QCM-D) is a unique technique to measure the adsorption capacity and viscoelasticity of proteins on the metal surface, which can be used to infer the orientation and conformation changes of adsorbed proteins [79, 80]. Rechendorff et al. studied the changes of proteins adsorbed on Ta films with different roughness by using QCM-D, the results showed that the adsorption amount of fibrinogen increased with the increase of surface roughness, because it had a slender shape and could be adsorbed and bound together in different directions with the growth of strong anisotropy, while BSA had a more spherical shape, and roughness did not promote conformation change [81]. Hovgaard et al. also believe that nano Ta oxide promotes additional protein conformational changes and subsequent RGD site exposure, thereby activating the surface [79]. Studies have shown that type I collagen is also widely used in the adhesion model system of various cell lines in vitro, it has strong adhesion to Ta, which may be because the longitudinal period of collagen fiber matches the grain size of Ta’s structural domain and also leads to stronger hydrophobic properties on the surface [82]. Among different Ta Nanomorphology, the regions with the highest amount of fibronectin adhesion have more effective utilization of cell binding areas, and the formation of fibronectin adhesion spots is also the most obvious [83]. Also, physical adsorption and silylation covalently combined methods were used to fix polypeptides onto Ta-based materials, and functional modification of the Ta surface was carried out to improve biological activity [84]. Sharma et al. observed with 251 labeled protein that when the thickness of the Ta oxide film increased, the water contact angle decreased, and the adsorption of fibrin on the oxide film coating increased compared with naked Ta [85]. Lundin et al. showed that although almost all proteins had a high affinity for Cr and SS (AISI 316) under acidic and neutral conditions, increasing the release of ions of Cr and SS, which may be due to the complexation between proteins and metals [86]. Protein adsorption determines subsequent cell-surface interactions. Among them, the adsorption of albumin as a cell adhesion inhibitor does not contain the peptide sequence that promotes the adhesion of specific cells. However, cells growing on the surface of Ta covered with fibronectin and serum proteins can reconstruct the surface to meet the requirements of cell growth through the production of endogenous matrix proteins [67].

Fig. 5
figure 5

The adsorption of different types of proteins on the Ta surface

4.4 Hematology experiment

Any biological material in contact with blood needs to be evaluated for blood compatibility. The effects of biomaterials on erythrocyte morphology and thrombosis were evaluated by platelet adhesion and activation, hemolysis test and clotting time test [87, 88]. Platelet works in the case of vascular injury, platelet diffusion and aggregation on the surface are a sign of platelet activation and are considered to be the main mechanism of thrombosis, which is adverse to blood compatibility of metal implant materials [88]. And in the hemolysis test, hemolysis rate measurement is important, besides, the morphology of red blood cells on the surface of the material can be observed by scanning electron microscope and optical microscope. The morphology of red blood cells on the surface of materials with a low hemolysis rate is often a normal double concave. If there is deformation and swelling, the hemolysis rate will increase to a certain extent [88]. Under normal circumstances, the hemolysis rate below the security threat threshold of 5% is considered qualified [89]. These indexes related to blood compatibility are closely related to surface energy, interfacial tension, grain size and other surface physical properties of Ta [90]. Adding Ta to different metal surface membranes in vitro can enhance the blood compatibility of metals. Ti oxide films containing Ta (Ti(Ta+5)O2) have been prepared by magnetron sputtering and thermal oxidation, indicating excellent biocompatibility, this is partly because the smaller surface force γs on the surface membrane and the smaller boundary membrane surface tension γc blood cause less distortion and adsorption of proteins on the surface, mainly fibrinogen, which is closely related to platelet activation [91]. Another study has shown that Ta injection technology was used to prepare TiO2/Ta2O5 composite nanofilm on the surface of NiTi shape memory alloy, after implantation, surface energy and interfacial tension were decreased, Water Contact Angle was increased, platelet adhesion and activation were weakened, hemolysis rate was reduced by at least 46%, and corrosion resistance was improved [90]. Nie et al. used equal channel angular pressing (ECAP) technology to prepare 8-pass block superfine crystal pure Ta, with more passes and more refined grains, the average grain size of the eighth pass reached 220 nm, and it was a typical body-centered cubic (BCC) structure. With the decrease of particle size, hemolysis rate and the number of adhered platelets decreased, mechanical strength increased [87]. Studies on other metals have shown that the most important factor for thrombotic reduction is the minimal adsorption of thrombotic blood proteins on the surface, thereby reducing the interaction with coagulation factors. Although the adsorption of fibronectin on the surface of Ta will further promote the early diffusion and adhesion of cells, it may also activate the coagulation cascade reaction and promote the adhesion and aggregation of platelets. In the complex physiological environment of the body, this mechanism of platelet activation is inevitable after biomaterials are implanted into the bone. Therefore, it is necessary to evaluate and consider the ways to enhance the ability of bone binding and integration of adherent cells on the surface of materials and to minimize platelet adhesion and activation.

4.5 Porous tantalum trabecular metal

Biomedical applications of solid Ta have been limited due to its high mechanical strength and density (16.68 g/cm3), PTTM is mainly used in bone tissue implantation at present. PTTM has a connected porous structure with a pore size of 300–600 μm and a porosity of 75–85% [92]. The main preparation methods include chemical vaporous deposition (CVD), organic foam impregnation and laser engineering net forming [93,94,95]. Porous Ta with different pore diameters and porosity can be produced by different manufacturing methods. The pore diameter is closely related to the growth of tissue cells and blood vessels, thus the porosity is designed to coordinate the elastic modulus between Ta and bone tissue. Bone induction (inducing osteogenic differentiation of MSCs) is also a necessary condition for porous Ta to induce bone formation and enhance bone bonding. With the increase of bone incorporation, the average interfacial shear strength is higher than that of other porous materials with lower volume porosity [96]. This special geometric structure and strength are of great significance to the biological properties of implanted materials.

PTTM has long been used in orthopedics to promote neovascularization, wound healing and osteogenesis, and in recent years, it has been incorporated into Ti alloy dental implants [97,98,99]. In vivo experiments, studies have shown that the bone growth, the amount of new mineralized bone and the rate of new bone formation of Ta trabecular dental implant (TM) is better than that of Ti dental implant (TSV), and TM dental implant has considerable implant stability and bone-implant contact [100, 101]. At present, many studies have incorporated TM into Ti alloy dental implants to improve osseointegration, and the results show that there is less bone loss around TM implants than the Ti group [99]. Macheras et al. analyzed the survival rate of the porous Ta acetabular component in primary total hip arthroplasty (THA) and followed up for an average of 18 years. Harris hip score, Oxford hip score, and range of motion were significantly improved in all cases (P < 0.001). At the last follow-up, all acetabular cups showed excellent clinical and imaging results [102]. Sagherian et al. retrospectively analyzed patients who failed ankle arthroplasty with TM treatment, followed up for an average of 57 months, and the American Orthopedic Foot and Ankle Score (AOFAS) increased from 30.7 preoperatively (range 20–39) to 72.7 (range 65–77), with an average of 3 months after arthrodesis without complications [103]. Papacci et al. concluded that anterior cervical discectomy and fusion (ACDF) with a porous Ta cage is a safe approach with long-term clinical benefits and a very low incidence of complications [104]. It can be seen that the joint reconstruction and revision of TM can be said to be successful in clinical application, which greatly improves the quality of life of patients. However, in the case of failure of porous Ta implant, the space between bone and implant can be seen, with sparse and isolated bone growth, which may be due to incorrect position, ineffective bone implantation, ineffective core decompression, etc. [105]. The initial stability of porous Ta implants should not only have good bone integration but also related to reasonable implant diameter and bone mineral density. In dense bone masses, large-diameter implants provide a larger bone-implant contact area, which is more stable than narrow implants, however, in cartilage masses, conical screw implants are more stable than TM implants because of the existence of threads on its entire surface [106]. Therefore, the success of the implant depends not only on the inherent properties of the material but also on the corresponding mechanical properties of the corresponding part.

5 Conclusion

At present, the main research direction of Ta-based biomaterials in the medical field is as bone implant materials. The evaluation of biocompatibility of Ta-based biomaterials mainly focuses on corrosion resistance, cell growth, and bone integration. When electrochemical corrosion behavior characterizes the corrosion resistance of Ta, the formation and stability of surface passivation film play an important role in the measurement results. Therefore, the stable surface oxidation film of Ta is one of the key factors of corrosion resistance. Compared with other metal materials, Ta as an implant material has the following advantages: (1) PTTM has an elastic modulus that matches human bone tissue, which can well meet the requirements of bone tissue replacement materials. (2) Ta’s excellent corrosion resistance can greatly reduce the release of metal ions caused by corrosion of implants in vivo. (3) The surface cell behavior of Ta is better than that of Cr, Ni, and even Ti. (4) Most kinds of literature reported that Ta had better osteogenic differentiation ability than Ti in prosthesis and implant coating, which could promote early osseointegration and stability of implants. (5) The nano-scale chemistry and morphology of the Ta topographic surface is beneficial to protein adsorption and the improvement of blood compatibility. (6) Regular follow-up after intraosseous PTTM implantation revealed excellent clinical effects, quality of life and a low incidence of complications. Although Ta has many advantages, Ta is a refractory metal element with a high melting point, easy oxidation under high temperature, and other characteristics, difficult material processing and high cost, which limit its wide application. In the early stage, we combined 3D printing technology to break the bottleneck of processing technology. In a word, Ta has a wide range of medical prospects because of its many characteristics make it suitable for in vivo implantation.