FormalPara Key Summary Points

Continuous glucose monitoring systems are increasingly being adopted as an alternative to self-monitoring of blood glucose/point of care testing (SMBG/POCT) by persons with diabetes receiving insulin therapy.

Flash glucose monitoring is demonstrated to facilitate better glucose monitoring, reduce the event rate of hypoglycemia, and improve quality of life of diabetes patients.

The IQVIA CORE Diabetes Model v9.5 was used to compare the cost-effectiveness of flash glucose monitoring versus SMBG/POCT for both patients with type 1 and patients with type 2 diabetes from a Chinese societal perspective.

The analyses showed that flash glucose monitoring was cost-effective compared with SMBG/POCT, with an incremental cost-effectiveness ratio of Chinese yuan (CNY) 47,636 per quality-adjusted life years gained in patients with type 1 diabetes and CNY 140,297 per quality-adjusted life years gained in patients with type 2 diabetes.

Scenario analyses further demonstrated that flash glucose monitoring was likely to be an optimal option from both health outcomes and economic considerations compared to SMBG/POCT.

Introduction

Diabetes is a major public health concern worldwide [1]. The aging of the diabetic population has raised dramatic needs for better healthcare service [2, 3]. A recent study indicated that the prevalence of diabetes in mainland China has increased from 10.9% in 2013 to 12.8% in 2017 [4]. This climb in prevalence is mostly ascribed to type 2 diabetes (T2D) [5], but the incidence of type 1 diabetes (T1D) has also witnessed a rapid increase, especially among children with an approximately fourfold growth in the last 20 years [6,7,8].

Insulin therapy is the mainstream treatment for diabetes. At the disease onset, 93.9% of patients with T1D would immediately initiate insulin treatment, while some patients with T2D may also receive insulin treatment but with a lower daily dose [8,9,10]. Insulin is effective in lowering glucose level, but too much insulin or other diabetes medications may cause the blood sugar level to drop too low, causing hypoglycemia, which can lead to coma and even death [11]. Furthermore, severe hypoglycemia episodes have led to a great economic burden on both global and Chinese healthcare systems [12, 13].

Glucose monitoring has been recognized as one of the most important components in diabetes management. Knowing patients’ current glucose reading is often the first step to further adjust patients’ diets, activities, and medications to achieve their glycemic goals [14, 15]. The self-monitoring of blood glucose (SMBG/POCT) is the mainstream and standard of blood glucose monitoring approach in China [15]. It is universally considered to be an integral part of T1D management and crucial for optimizing the safety of patients with T2D. Patients with diabetes can receive real-time glucose level through SMBG/POCT and adjust their diet and treatment dose accordingly [16]. However, SMBG/POCT cannot detect nocturnal hypoglycemia and asymptomatic hypoglycemia, and it needs multiple finger-stick blood samples throughout the day. Therefore, SMBG/POCT may cause pain, discomfort, and compliance issues. In addition, SMBG/POCT cannot provide any information on glucose trends, which may miss important glucose fluctuations [17].

Continuous glucose monitoring (CGM) systems are increasingly being adopted as an alternative to SMBG/POCT by persons with diabetes receiving insulin therapy. Unlike SMBG/POCT which can only provide a single instant glucose value for each test, CGM can offer continuous glucose data as a reference to adjust insulin therapy and monitor lifestyle intervention [17]. Nevertheless, conventional CGM still requires calibration via SMBG/POCT measurements to ensure accuracy [18].

A flash glucose monitoring system (hereinafter referred to as “flash monitoring”) measures glucose levels in the interstitial fluid every minute, allowing for continuous glucose measurement. Thus, flash monitoring is sometimes referred to as intermittently scanned CGM (isCGM). Compared with SMBG/POCT and conventional CGM, it can be particularly beneficial to patients with diabetes who need long-term glucose monitoring and accurate trends of glucose [19]. In flash monitoring, patients have a sensor worn on the back of their upper arm to measure the glucose, and a separate reader to swipe over the sensor to get the glucose data. In China, there are an individual version (FreeStyle Libre; Abbott Diabetes Care, Witney, UK) mainly for out-of-hospital use, and a hospital version (FreeStyle Libre H; Abbott Diabetes Care, Witney, UK) of flash monitoring for hospital settings. Each sensor for flash monitoring (no matter whether the hospital version or individual version) can be used for up to 14 days without calibration via SMBG/POCT measurements. Each sensor could be matched with one reader for the individual version, while the hospital version enables one reader to connect multiple sensors and monitor the glucose level of multiple patients. Results from several randomized controlled trials (RCTs) and real-world evidence (RWE) studies suggested that flash monitoring can facilitate better glucose monitoring, reduce time in hypoglycemia, increase time in normal glucose range, and improve quality of life and patient satisfaction compared with SMBG/POCT [20, 21].

Previous studies indicated that flash monitoring is cost-effective in Sweden, Greece, and the UK [22,23,24]. However, no studies addressed its cost-effectiveness in China, and none of the previous studies considered the use of a combination of individual version and hospital version of flash monitoring. To fill this gap, our study aims to evaluate the cost-effectiveness of using flash monitoring (hospital version and individual version) versus SMBG/POCT for insulin-treated patients with T1D and patients with T2D in China.

Methods

CORE Diabetes Model

IQVIA CORE Diabetes Model (CDM) 9.5 version was used for the analyses. The CDM is an internet-based model, simulating the long-term health outcomes and economic consequences of interventions in T1D and T2D. There are 17 interdependent sub-models with the combination of Monte Carlo simulation and Markov modelling designed as the underlying mathematical engine to capture the long-term progression of diabetes complications. The CDM allows the estimation in life expectancy, quality-adjusted life years (QALYs), direct costs, and indirect costs. Past validation studies have confirmed the IQVIA CDM as a credible tool to support policy decisions related to disease management in T1D and T2D [25].

The study was performed from the Chinese societal perspective (indirect costs were not included for patients with T2D as the start age of T2D in this analysis was older than the retirement age). Costs and health outcomes were evaluated over a lifetime horizon. Both costs and health outcomes were discounted at an annual rate of 5% [26]. As there is no documentation on the willingness-to-pay (WTP) threshold for a QALY gained in China, three times the annual gross domestic product (GDP) per capita, Chinese yuan (CNY) 217,341 in 2020 as recommended by the World Health Organizations Commission on Macroeconomics and Health, was used as threshold in this study.

This study is based on previously conducted studies and does not contain any new studies with human participants or animals performed by any of the authors.

Data Collection

Pragmatic reviews were conducted in PubMed, CNKI, and WANFANG database to obtain the best available model inputs. The reviews focused on patient baseline characteristics and healthcare costs of diabetes-related complications. For inputs with multiple sources, we selected the data from the latest and best representative source for Chinese patients with diabetes. Then, in-depth clinical expert interviews were conducted to validate model inputs. The five experts were selected considering their experience in diabetes management and glucose monitoring.

Model Inputs

Cohort

Cohort baseline characteristics were identified from published literature. For those unavailable data inputs, we used the median of interview results. Detailed cohort baseline characteristics are listed in Table 1 and Supplementary Table S1.

Table 1 Cohort characteristics

Intervention Effects

In this study, the intervention is flash monitoring versus SMBG/POCT among insulin-treated patients with T1D and patients with T2D. The intervention effects of flash monitoring were retrieved from two RCTs of flash monitoring, the IMPACT trial for patients with T1D and the REPLACE trial for patients with T2D [27, 28].

Although no significant differences were seen in the effect on HbA1c, the values of HbA1c changes by the end of the studies were still used as the change from baseline HbA1c at the end of year 1. For patients with T1D, an increase of 0.15% in the flash monitoring arm and 0.17% in the SMBG/POCT arm were implemented in the analyses [27]; for patients with T2D, a reduction of 0.29% in the flash monitoring arm and 0.31% in the SMBG/POCT arm were used [28].

Hypoglycemia was defined as three levels in CDM: (1) non-severe hypoglycemia event (NSHE); (2) severe hypoglycemia event grade 1 (SHE1), requiring non-medical assistance; and (3) severe hypoglycemia event grade 2 (SHE2), requiring medical assistance. Event rates of non-severe and severe hypoglycemia in the SMBG/POCT arm were retrieved from a long-term observational study for patients with T1D and a meta-analysis for patients with T2D [29, 30]. We used the CDM default proportion to separate SHE1 and SHE2 [31]. The event rates of the flash monitoring arm were calculated on the basis of the relative differences compared to the SMBG/POCT arm. The relative differences were extracted from the IMPACT trial and REPLACE trial for patients with T1D and patients with T2D, respectively [27, 28].

In addition to the hypoglycemia events, we also considered the impact of ketoacidosis events for patients with T1D. Data from a recent real-world study that published the ketoacidosis event rates in patients with T1D were used [32]. Our analyses for T2D did not consider ketoacidosis events as they rarely occur in patients with T2D [33]. Detailed treatment effects data are presented in Table 2.

Table 2 Treatment effects

Cost Inputs

Costs included glucose monitoring costs, insulin therapy costs, diabetes-related chronic complication treatment costs, acute event treatment cost, screening costs, and indirect costs (only for the T1D cohort). All costs data were inflated to 2021 Chinese currency using consumer price index from the National Bureau of Statistics of China. Details can be seen in Table 3 and Supplementary Tables S2 and S3.

Table 3 Intervention costs and acute event treatment costs

The monitoring frequency of SMBG/POCT was derived from the IMPACT and REPLACE trials [27, 28]. It is worth noting that for patients using flash monitoring, SMBG/POCT was also administered. The monitoring frequency of SMBG/POCT was 0.5 tests/day and 0.3 tests/day for patients with T1D and patients with T2D using flash monitoring, and 5.6 tests/day and 3.8 tests/day for patients using SMBG/POCT.

According to the clinical interview results, the average numbers of inpatient visit for Chinese patients with T1D and patients with T2D were 1.3 times/year and 1 time/year, and the average lengths of stay were 8.1 days and 7 days. As there are both a hospital version and individual version of flash monitoring in China, our analyses assumed that patients with T1D and patients with T2D would use 1.3 hospital version sensors and 1 hospital version sensor each year, respectively. Except for the inpatient stay, patients would use the individual version of flash monitoring. Similarly, different unit costs of SMBG/POCT test were used for hospital and out-of-hospital settings.

The baseline insulin dosages of Chinese patients with T1D and patients with T2D were obtained from two retrospective studies [34, 35], and further calculated considering the change observed in the IMPACT and REPLACE trials after 6 months of glucose monitoring using different approaches [27, 28].

Diabetes-related chronic complication frequencies were simulated by CDM. The cardiovascular (CV) disease risks were calculated by using China-PAR (prediction for atherosclerotic cardiovascular disease risk in China) CV risk equations to better reflect the correlation between patient characteristics and CV outcomes in the Chinese population. Acute event treatment costs in patients with T1D included treatment costs for severe hypoglycemia and ketoacidosis, while only severe hypoglycemia treatment costs were included for patients with T2D. These acute events were considered without long-term component, and the costs occur only once and are applied in the same year as the corresponding event. The indirect costs calculated the productivity loss resulting from morbidity and mortality associated with the disease for patients of working age. Costs per day absent from work are calculated separately for male and female patients on the basis of their average annual salary and the number of working days per year respectively. Each ongoing complication and acute event is associated with a certain number of days absent from work. As the baseline age of patients with T2D was older than the retirement age in China, no indirect costs were calculated for T2D.

Utilities, Disutility, and Mortality

A treatment-related disutility of − 0.03 was applied to the SMBG/POCT arm in accordance with published research [36]. The mortality of severe hypoglycemia events, 10.77%, retrieved from a recent study in Chinese diabetes population was also implemented into the model to better calibrate the results [37]. In addition, as ketoacidosis events were considered in the analyses, the mortality of ketoacidosis events in T1D, 2.7%, was also included [38].

Supplementary Table S4 shows other utilities and disutilities for diabetes complications. Supplementary Table S5 shows the non-specific mortality for the Chinese population.

Scenario and Sensitivity Analyses

RWE Scenario Analysis

To better reflect the potential benefits of flash monitoring in real-world settings, we conducted a scenario analysis with HbA1c treatment effect from study population whose baseline HbA1c was the closest to Chinese patients with diabetes. For T1D, the change in HbA1c using flash monitoring was retrieved from a real-world study whose baseline HbA1c was most similar to Chinese patients with T1D (10.28% in the real-world study vs.10.3% in Chinese patients with T1D) [34]. The − 0.88% change from baseline HbA1c using flash monitoring was implemented in this scenario analysis. Similarly, a − 0.5% change from the baseline HbA1c was adopted for patients with T2D in the scenario analysis [35].

Sensitivity Analysis

One-way sensitivity analysis (OWSA) and probabilistic sensitivity analysis (PSA) were performed to test the robustness of results in an RCT scenario concerning variable uncertainties and modeling assumptions. The following OWSAs were also conducted for both T1D and T2D: event rate of NSHE and SHE (from published Chinese literature [13]), discount rate (0% or 8%), time horizon (5 years), disutility of NSHE and SHE (the upper and lower limits of 95% CI), SMBG/POCT treatment disutility (the upper and lower limits of 95% CI), flash monitoring sensor cost (− 20%), insulin cost (± 20%), complication treatment cost (± 20%), and SMBG/POCT frequency (7 times per day recommended by Chinese guidelines [15]).

PSA was conducted to test the composite parameter uncertainty using Monte Carlo simulation with 1000 expected values of flash monitoring and SMBG/POCT.

Results

RCT Scenario

According to the intervention effects from RCTs, flash monitoring was associated with an incremental benefit of 1.22 QALYs and an increased cost of CNY 58,021 compared with SMBG/POCT for patients with T1D. As for patients with T2D, flash monitoring was associated with an incremental benefit of 0.65 QALYs and an increased cost of CNY 90,997 compared with SMBG/POCT. Given a WTP threshold of three times the GDP per capita in China (CNY 217,341 in 2020), flash monitoring was a cost-effective option for both patients with T1D and patients with T2D, resulting in an incremental cost-effectiveness ratio (ICER) of CNY 47,636 per QALY gained and CNY 140,297 per QALY gained, respectively. The full results are presented in Table 4.

Table 4 Results from RCT and RWE scenarios

RWE Scenario

The results of using treatment effect of HbA1c change from real-world studies are reported in Table 4. In this scenario analysis, flash monitoring dominated SMBG/POCT in patients with T1D, and yield ICER of CNY 124,169 per QALY gained compared with SMBG/POCT in patients with T2D.

Sensitivity Analyses

Sensitivity analyses showed that the results were robust to variable changes. Flash monitoring remained cost-effective compared with SMBG/POCT in all the scenarios investigated (results are presented in Table 5).

Table 5 Sensitivity analysis results (CNY/QALY)

Figure 1 presents the probability of being cost-effective at different WTP values in the form of cost-effectiveness acceptability curves. When the WTP threshold was set to CNY 217,341 per QALY gained, the probability of flash monitoring being a cost-effective strategy compared with SMBG/POCT is 100% for T1D under both scenarios, and 97.2% and 99.1% for T2D under the RCT scenario and RWE scenario, respectively. Other PSA results presented in scatter plots can be found in Supplementary Figs. S1 and S2.

Fig. 1
figure 1

Cost-effectiveness acceptability curves under different scenarios. T1D type 1 diabetes, T2D type 2 diabetes, RCT randomized clinical trial, RWE real-world evidence

Discussion

As the first cost-effectiveness study of flash monitoring in China, our study found that flash monitoring is likely to be a cost-effective option compared with SMBG/POCT, with favorable ICERs at CNY 47,636 and CNY 140,297 for patients with T1D and patients with T2D, considering the treatment effect in IMPACT/REPLACE trials. Although flash monitoring is more expensive than SMBG/POCT in glucose monitoring under current prices and SMBG/POCT test frequency, flash monitoring can offset the cost in acute events (ketoacidosis and hypoglycemia in T1D; hypoglycemia in T2D), and reduce indirect cost (productivity loss in T1D only) with additional QALYs. Flash monitoring per se may not directly alter the glucose level of patients with diabetes, but it is considered as part of diabetes management strategy. Improvements in acute events can be achieved through flash monitoring owing to more convenient access to real-time sensor glucose results with trend arrows, which inform the lifestyle modification. Meanwhile, flash monitoring provides more fluent glucose data to guide the insulin adjustment by physicians [28].

IMPACT and REPLACE studies suggested no significant differences in HbA1c changes comparing flash monitoring with SMBG/POCT. Nevertheless, the results could be partially explained by the good glycemic control of the study population. According to a meta-analysis including 25 studies, flash monitoring could result in a significant and sustained reduction in HbA1c and the degree of change in HbA1c was correlated to the baseline HbA1c level of the study population [39]. Given the different baseline HbA1c level between IMPACT/REPLACE trial and Chinese patients with diabetes, a comprehensive cost-effectiveness evaluation from both RCT and RWE scenarios could shed light on future decision-making [9, 27, 28, 40].

The results from RWE scenario analysis also showed promising cost-effectiveness of flash monitoring compared to SMBG/POCT. Flash monitoring dominates SMBG/POCT in Chinese patients with T1D with reduced costs and better health outcomes. Similarly, the result of implementing treatment effect from real-world studies in T2D strengthened flash monitoring’s cost-effectiveness, with an ICER of CNY 124,169. Results under the RWE scenario demonstrated the potential of flash monitoring in reducing chronic complication costs in both patients with T1D and patients with T2D owing to its favorable effect in HbA1c reduction.

As an innovative glucose monitoring approach, flash monitoring is increasingly used in diabetes management in both hospital and out-of-hospital settings. A review of 17 health technology assessment (HTA) reports on flash monitoring has reached a conclusion on its efficacy in reducing events, time in hypoglycemia, improving patient satisfaction, as well as its potential to be cost-effective or cost saving in certain patient populations [20]. Our study results further demonstrate the potential of flash monitoring to be a cost-effective option compared with SMBG/POCT in the Chinese setting.

Apart from this analysis, there are some published abstracts, articles, and HTA reports comparing the cost-effectiveness of flash monitoring and SMBG/POCT in western populations [22,23,24]. Overall, results of our study were consistent with previous studies. One study found that flash monitoring led to 0.56 additional QALYs in patients with T2D from the Swedish societal perspective [22]. Another study using CDM conducted from a Greek payer perspective reached a similar conclusion that flash monitoring may create 0.567 and 0.317 additional QALYs compared to SMBG/POCT for T1D and T2D, respectively [24]. Even using different modelling approaches, an HTA conducted in Scotland arrived at the same conclusion [41].

Some limitations of the study should be acknowledged. First, health outcome simulation and prediction in this model were mainly conducted on the basis of efficacy data from clinical trials and real-world studies in western populations. Although there are some Chinese-specific clinical studies of flash monitoring, considering the study design (small sample size and short follow-up period), Chinese-specific clinical efficacy data were not used in our analyses. Nevertheless, clinical studies for Chinese patients with T1D and patients with T2D yielded similar treatment effect, such as the reduction of hypoglycemia events and the changes in HbA1c from baseline [42,43,44,45].

Some Chinese population baseline clinical data were also missing in our analyses, e.g., the hypoglycemia event rates in Chinese patients with T1D and patients with T2D receiving insulin treatment. To understand the potential impact on results, a scenario analysis using hypoglycemia event rates from the Chinese study was also conducted (no specified data for patients with T1D or T2D, assuming equal event rates of hypoglycemia in T1D and T2D) [13]. Results showed that flash monitoring is still cost-effective compared with SMBG/POCT in both patients with T1D and patients with T2D, demonstrating the robustness of base case results. Future studies are expected with more Chinese population-specific data.

In addition, similar to previous cost-effectiveness studies, the treatment pathway was simplified for both patients with T1D and patients with T2D under the assumption of unchanged use of glucose monitoring and insulin, as the change would not alter the conclusion of the study [22]. However, the frequency of glucose monitoring and the dosage of insulin use are likely to change over time in the real-world clinical setting.

Despite limitations, our study used a well-validated model with best available data inputs and adopted scenarios and sensitivity analyses to disclose comprehensive cost-effectiveness findings. We used different levels of hypoglycemia and nocturnal hypoglycemia, and combining hospital and individual version flash monitoring, to reflect the current clinical reality. Scenarios of HbA1c treatment effect from real-world studies were also analyzed. In comparison with medicines, the cost-effectiveness of medical devices is generally less examined because of the potential challenges of insufficient clinical evidence, shorter product lifecycle, inexplicit target population, etc. This study is valuable in providing implications for future cost-effectiveness studies of medical devices in China. Meanwhile, the study results may provide important references for diabetes disease management and reimbursement decision-making in China.

Conclusion

Compared with SMBG/POCT, flash monitoring enables better glucose control, further reducing expenditures in acute event treatments. Our analyses suggested that flash monitoring (combination use of hospital version and individual version) is likely to be a more cost-effective strategy for both T1D and T2D insulin users compare to SMBG/POCT from the Chinese societal perspective.