Abstract
Physics quality assurance (QA) is an integral part of a medical physicist’s role in the radiotherapy centre. Management of physics QA documents is an issue with a long-term accumulation. Storage space, archive administration and paper consumption are just some of the difficulties faced by physicists. Plotting trends and drawing meaningful conclusions from these results can be challenging using traditional QA methods. Remote checking of QA within a hospital network can also be problematic. The aim of this project is introduce a paperless QA system that will provide solutions to many of these issues.
Similar content being viewed by others
References
ARPANSA RPS14.3 Radiation protection in radiotherapy
Thwaites DJ, Mijnheer BJ, Mills JA (2005) Quality assurance of external beam radiotherapy. In: Podgorsak EB (ed) Radiation oncology physics: a handbook for teachers and students. International Atomic Energy Agency, Vienna, pp 407–450
Millar M, Cramb J, Das R, Ackerly T, Brown G, Webb D (1997) ACPSEM position paper. Recommendations for the safe use of external beams and sealed brachytherapy sources in radiation oncology. Australas Phys Eng Sci Med 20(3 Suppl):1–35
Report of AAPM Radiation Therapy Committee Task Group 40 (1994) Comprehensive QA for radiation oncology. Med Phys 21:581–618
International Electrotechnical Commission (1989) Medical electrical equipment—medical electron accelerators: functional performance characteristics, IEC 976. IEC, Geneva
Physics QA Protocols, Nepean Cancer Care Centre
Luo J, Yau S, White S, Wilfert L (1996)The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al–4 mm Cu HVL; 10–300 kV generating potential). Phys. Med. Biol. 41:2605–2625
Aukett RJ, Burns JE, Greener AG, Harrison RM, Moretti C, Nahum AE, Rosser KE, IPEM Working Party (2005) Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al–4 mm Cu HVL). Phys Med Biol 50:2739–2748
Absorbed dose determination in external beam radiotherapy, technical reports series No. 398, IAEA, Vienna (2000)
Report of the AAPM Radiation Therapy Committee Task Group No. 66 (2003) Quality assurance for computed-tomography simulators and the computed-tomography-simulation process. Med Phys 30:2762–2790
Author information
Authors and Affiliations
Corresponding author
Appendix
Appendix
See Table 1.
Rights and permissions
About this article
Cite this article
Luo, J., Yau, S., White, S. et al. Paperless medical physics QA in radiation therapy. Australas Phys Eng Sci Med 35, 237–243 (2012). https://doi.org/10.1007/s13246-012-0137-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-012-0137-1